21 CFR 820.180
General requirements
21 CFR 820.180 is the regulation titled “General requirements” in 21 CFR Part 820, Quality System Regulation (before Feb 2, 2026). Since 2021, 3 FDA warning letters have cited it.
Part 820 changed when FDA's Quality Management System Regulation took effect on February 2, 2026. This is the earlier text these letters cite.
- Letters citing it
- 3 since 2021
- Jan 1 to Oct 30, 2026
- 0 against 2 on the same dates in 2025
- Most often cited with
- 21 CFR 820.30, in 3 letters
- Closed out
- 0% of these letters have a published close-out
Letters citing it, by year issued
All are medical device letters. 2026 runs to Oct 30, 2026. Pick a year to see its letters.
The regulation
Read the text of 21 CFR 820.180 (eCFR, as of Jun 1, 2025)
All records required by this part shall be maintained at the manufacturing establishment or other location that is reasonably accessible to responsible officials of the manufacturer and to employees of FDA designated to perform inspections. Such records, including those not stored at the inspected establishment, shall be made readily available for review and copying by FDA employee(s). Such records shall be legible and shall be stored to minimize deterioration and to prevent loss. Those records stored in automated data processing systems shall be backed up.
(a) Confidentiality. Records deemed confidential by the manufacturer may be marked to aid FDA in determining whether information may be disclosed under the public information regulation in part 20 of this chapter.
(b) Record retention period. All records required by this part shall be retained for a period of time equivalent to the design and expected life of the device, but in no case less than 2 years from the date of release for commercial distribution by the manufacturer.
(c) Exceptions. This section does not apply to the reports required by § 820.20(c) Management review, § 820.22 Quality audits, and supplier audit reports used to meet the requirements of § 820.50(a) Evaluation of suppliers, contractors, and consultants, but does apply to procedures established under these provisions. Upon request of a designated employee of FDA, an employee in management with executive responsibility shall certify in writing that the management reviews and quality audits required under this part, and supplier audits where applicable, have been performed and documented, the dates on which they were performed, and that any required corrective action has been undertaken.
Text from eCFR as of Jun 1, 2025.
Cited alongside it
Regulations that appear in the same letters as 21 CFR 820.180.
- 21 CFR 820.30Design controls3 letters cite both
- 21 CFR 820.100Corrective and preventive action2 letters cite both
- 21 CFR 820.198Complaint files2 letters cite both
- 21 CFR 803.17What are the requirements for developing, maintaining, and implementing written MDR procedures that apply to me?1 letter cites both
- 21 CFR 806.10Reports of corrections and removals1 letter cites both
- 21 CFR 807.81When a premarket notification submission is required1 letter cites both
- 21 CFR 820.120Device labeling1 letter cites both
- 21 CFR 820.130Device packaging1 letter cites both
Latest letters citing it
The 3 letters citing 21 CFR 820.180 that FDA posted most recently.
- DevicesView Contec Medical Systems Co., Ltd.Patient monitors, ultrasound diagnostic systems, pulse oximeter, and fetal dopplerIssuedOct 2, 2025PostedOct 28, 2025
- DevicesView LEVO AGLEVO C3; LEVO Combi; LEVO LAE; and LEVO LCEV, Class II Standup WheelchairsIssuedJul 18, 2025PostedOct 21, 2025
- DevicesView Abbott Point of Care Canada Limitedi-STAT cTnI TestIssuedNov 8, 2022PostedApr 19, 2023