21 CFR Part 211 · Current Good Manufacturing Practice for Finished Pharmaceuticals

21 CFR 211.194

Laboratory records

21 CFR 211.194 is the regulation titled “Laboratory records” in 21 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals. Since 2021, 46 FDA warning letters have cited it.

Letters citing it
46 since 2021
Jan 1 to Oct 30, 2026
15 against 7 on the same dates in 2025
Most often cited with
21 CFR 211.22, in 31 letters
Closed out
2% of these letters have a published close-out
See the 46 letters citing 21 CFR 211.194 →

Letters citing it, by year issued

Most are drug letters (44 of 46). 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 12021
  2. 22022
  3. 42023
  4. 152024
  5. 92025
  6. 152026

What FDA writes when it cites it

The finding headings that cite 21 CFR 211.194 most often, as written in the letters.

  • 29 lettersYour firm failed to ensure that laboratory records included complete data derived from all tests necessary to ensure compliance with established specifications and standards (21 CFR 211.194(a))
  • 1 letterFailure to ensure that laboratory records include complete data derived from all tests necessary to assure compliance with established specifications and standards, as required by 21 CFR 211.194(a). For example: i.…
  • 1 letterOn multiple occasions, the number of active air monitoring samples documented in environmental monitoring records was not directly traceable to the instrument histories of the specific air samplers identified on those…

The regulation

Read the text of 21 CFR 211.194 (eCFR, as of Sep 1, 2026)

(a) Laboratory records shall include complete data derived from all tests necessary to assure compliance with established specifications and standards, including examinations and assays, as follows:

(1) A description of the sample received for testing with identification of source (that is, location from where sample was obtained), quantity, lot number or other distinctive code, date sample was taken, and date sample was received for testing.

(2) A statement of each method used in the testing of the sample. The statement shall indicate the location of data that establish that the methods used in the testing of the sample meet proper standards of accuracy and reliability as applied to the product tested. (If the method employed is in the current revision of the United States Pharmacopeia, National Formulary, AOAC INTERNATIONAL, Book of Methods, 1 or in other recognized standard references, or is detailed in an approved new drug application and the referenced method is not modified, a statement indicating the method and reference will suffice). The suitability of all testing methods used shall be verified under actual conditions of use.

(3) A statement of the weight or measure of sample used for each test, where appropriate.

(4) A complete record of all data secured in the course of each test, including all graphs, charts, and spectra from laboratory instrumentation, properly identified to show the specific component, drug product container, closure, in-process material, or drug product, and lot tested.

(5) A record of all calculations performed in connection with the test, including units of measure, conversion factors, and equivalency factors.

(6) A statement of the results of tests and how the results compare with established standards of identity, strength, quality, and purity for the component, drug product container, closure, in-process material, or drug product tested.

(7) The initials or signature of the person who performs each test and the date(s) the tests were performed.

(8) The initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.

(b) Complete records shall be maintained of any modification of an established method employed in testing. Such records shall include the reason for the modification and data to verify that the modification produced results that are at least as accurate and reliable for the material being tested as the established method.

(c) Complete records shall be maintained of any testing and standardization of laboratory reference standards, reagents, and standard solutions.

(d) Complete records shall be maintained of the periodic calibration of laboratory instruments, apparatus, gauges, and recording devices required by § 211.160(b)(4).

(e) Complete records shall be maintained of all stability testing performed in accordance with § 211.166.

[43 FR 45077, Sept. 29, 1978, as amended at 55 FR 11577, Mar. 29, 1990; 65 FR 18889, Apr. 10, 2000; 70 FR 40880, July 15, 2005; 70 FR 67651, Nov. 8, 2005]

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 211.194.

Latest letters citing it

The 3 letters citing 21 CFR 211.194 that FDA posted most recently.

See the 46 letters citing 21 CFR 211.194 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.