21 CFR 211.84
Testing and approval or rejection of components, drug product containers, and closures
21 CFR 211.84 is the regulation titled “Testing and approval or rejection of components, drug product containers, and closures” in 21 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals. Since 2021, 275 FDA warning letters have cited it.
- Letters citing it
- 275 since 2021
- Jan 1 to Oct 30, 2026
- 46 against 49 on the same dates in 2025
- Most often cited with
- 21 CFR 211.22, in 177 letters
- Closed out
- 4% of these letters have a published close-out
Letters citing it, by year issued
Most are drug letters (267 of 275). 2026 runs to Oct 30, 2026. Pick a year to see its letters.
What FDA writes when it cites it
The finding headings that cite 21 CFR 211.84 most often, as written in the letters.
- 59 lettersYour firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at…
- 50 lettersYour firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1))
- 44 lettersYour firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality. Your firm also failed to validate and establish the…
The regulation
Read the text of 21 CFR 211.84 (eCFR, as of Sep 1, 2026)
(a) Each lot of components, drug product containers, and closures shall be withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit.
(b) Representative samples of each shipment of each lot shall be collected for testing or examination. The number of containers to be sampled, and the amount of material to be taken from each container, shall be based upon appropriate criteria such as statistical criteria for component variability, confidence levels, and degree of precision desired, the past quality history of the supplier, and the quantity needed for analysis and reserve where required by § 211.170.
(c) Samples shall be collected in accordance with the following procedures:
(1) The containers of components selected shall be cleaned when necessary in a manner to prevent introduction of contaminants into the component.
(2) The containers shall be opened, sampled, and resealed in a manner designed to prevent contamination of their contents and contamination of other components, drug product containers, or closures.
(3) Sterile equipment and aseptic sampling techniques shall be used when necessary.
(4) If it is necessary to sample a component from the top, middle, and bottom of its container, such sample subdivisions shall not be composited for testing.
(5) Sample containers shall be identified so that the following information can be determined: name of the material sampled, the lot number, the container from which the sample was taken, the date on which the sample was taken, and the name of the person who collected the sample.
(6) Containers from which samples have been taken shall be marked to show that samples have been removed from them.
(d) Samples shall be examined and tested as follows:
(1) At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used.
(2) Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
(3) Containers and closures shall be tested for conformity with all appropriate written specifications. In lieu of such testing by the manufacturer, a certificate of testing may be accepted from the supplier, provided that at least a visual identification is conducted on such containers/closures by the manufacturer and provided that the manufacturer establishes the reliability of the supplier's test results through appropriate validation of the supplier's test results at appropriate intervals.
(4) When appropriate, components shall be microscopically examined.
(5) Each lot of a component, drug product container, or closure that is liable to contamination with filth, insect infestation, or other extraneous adulterant shall be examined against established specifications for such contamination.
(6) Each lot of a component, drug product container, or closure with potential for microbiological contamination that is objectionable in view of its intended use shall be subjected to microbiological tests before use.
(e) Any lot of components, drug product containers, or closures that meets the appropriate written specifications of identity, strength, quality, and purity and related tests under paragraph (d) of this section may be approved and released for use. Any lot of such material that does not meet such specifications shall be rejected.
[43 FR 45077, Sept. 29, 1978, as amended at 63 FR 14356, Mar. 25, 1998; 73 FR 51932, Sept. 8, 2008]
Text from eCFR as of Sep 1, 2026.
Cited alongside it
Regulations that appear in the same letters as 21 CFR 211.84.
- 21 CFR 211.22Responsibilities of quality control unit177 letters cite both
- 21 CFR 211.100Written procedures; deviations150 letters cite both
- 21 CFR 211.165Testing and release for distribution142 letters cite both
- 21 CFR 211.166Stability testing110 letters cite both
- 21 CFR 211.160General requirements64 letters cite both
- 21 CFR 211.192Production record review61 letters cite both
- 21 CFR 201.128Meaning of “intended uses”60 letters cite both
- 21 CFR 211.188Batch production and control records55 letters cite both
Latest letters citing it
The 3 letters citing 21 CFR 211.84 that FDA posted most recently.
- DrugsView Conroe Welding Supply, Inc.Oxygen, USP for administration by inhalationIssuedOct 29, 2026PostedNov 3, 2026
- DrugsView Pritam International Private LimitedBrush Buddies Cookies 'n Cream Ice Cream Flavored ToothpasteIssuedOct 27, 2026PostedNov 3, 2026
- DrugsView Guangdong Bangze Medicine Co., Ltd.OTC drug productsIssuedOct 26, 2026PostedNov 3, 2026
Put this kind of reading to
work on your own records.
Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.
Counts include every citation in a letter, as the Letters filter does. How this database is built.