21 CFR Part 200 · General

21 CFR 200.50

Ophthalmic preparations and dispensers

21 CFR 200.50 is the regulation titled “Ophthalmic preparations and dispensers” in 21 CFR Part 200, General. Since 2021, 8 FDA warning letters have cited it.

Letters citing it
8 since 2021
Jan 1 to Oct 30, 2026
0 against 0 on the same dates in 2025
Most often cited with
21 CFR 201.128, in 4 letters
Closed out
13% of these letters have a published close-out
See the 8 letters citing 21 CFR 200.50 →

Letters citing it, by year issued

Most are drug letters (7 of 8). 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 12021
  2. 02022
  3. 42023
  4. 32024
  5. 02025
  6. 02026

What FDA writes when it cites it

The finding headings that cite 21 CFR 200.50 most often, as written in the letters.

  • 1 letterDelsam Pharma’s ARTIFICIAL TEARS and Delsam Pharma’s ARTIFICIAL EYE OINTMENT are misbranded under section 502(j) of the FD&C Act, 21 U.S.C. 352(j), because they are not sterile
  • 1 letterEZRICARE Artificial Tears is misbranded under section 502(j) of the FD&C Act, 21 U.S.C. 352(j), because it is not sterile

The regulation

Read the text of 21 CFR 200.50 (eCFR, as of Sep 1, 2026)

(a)(1) Informed medical opinion is in agreement that all preparations offered or intended for ophthalmic use, including preparations for cleansing the eyes, should be sterile. It is further evident that such preparations purport to be of such purity and quality as to be suitable for safe use in the eye.

(2) The Food and Drug Administration concludes that all such preparations, if they are not sterile, fall below their professed standard of purity or quality and may be unsafe. In a statement of policy issued on September 1, 1964, the Food and Drug Administration ruled that liquid preparations offered or intended for ophthalmic use that are not sterile may be regarded as adulterated within the meaning of section 501(c) of the Federal Food, Drug, and Cosmetic Act (the act), and, further, may be deemed misbranded within the meaning of section 502(j) of the act. This ruling is extended to affect all preparations for ophthalmic use. By this regulation, this ruling is applicable to ophthalmic preparations that are regulated as drugs. By the regulation in § 800.10 of this chapter, this ruling is applicable to ophthalmic preparations that are regulated as medical devices.

(3) The containers of ophthalmic preparations shall be sterile at the time of filling and closing, and the container or individual carton shall be so sealed that the contents cannot be used without destroying the seal. The packaging and labeling of ophthalmic preparations that are over-the-counter drugs shall also comply with § 211.132 of this chapter on tamper-resistant packaging requirements.

(b) Liquid ophthalmic preparations packed in multiple-dose containers should:

(1) Contain one or more suitable and harmless substances that will inhibit the growth of microorganisms; or

(2) Be so packaged as to volume and type of container and so labeled as to duration of use and with such necessary warnings as to afford adequate protection and minimize the hazard of injury resulting from contamination during use.

(c) Eye cups, eye droppers, and other dispensers intended for ophthalmic use should be sterile, and may be regarded as falling below their professed standard of purity or quality if they are not sterile. These articles, which are regulated as drugs if packaged with the drugs with which they are to be used, should be packaged so as to maintain sterility until the package is opened and be labeled, on or within the retail package, so as to afford adequate directions and necessary warnings to minimize the hazard of injury resulting from contamination during use.

[40 FR 13996, Mar. 27, 1975, as amended at 47 FR 50455, Nov. 5, 1982]

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 200.50.

Latest letters citing it

The 3 letters citing 21 CFR 200.50 that FDA posted most recently.

See the 8 letters citing 21 CFR 200.50 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.