21 CFR Part 1271 · Human Cells, Tissues, and Cellular and Tissue-Based Products

21 CFR 1271.10

Are my HCT/P's regulated solely under section 361 of the PHS Act and the regulations in this part, and if so what must I do?

21 CFR 1271.10 is the regulation titled “Are my HCT/P's regulated solely under section 361 of the PHS Act and the regulations in this part, and if so what must I do?” in 21 CFR Part 1271, Human Cells, Tissues, and Cellular and Tissue-Based Products. Since 2021, 36 FDA warning letters have cited it.

Letters citing it
36 since 2021
Jan 1 to Oct 30, 2026
6 against 6 on the same dates in 2025
Most often cited with
21 CFR 1271.15, in 36 letters
Closed out
8% of these letters have a published close-out
See the 36 letters citing 21 CFR 1271.10 →

Letters citing it, by year issued

All are biologics letters. 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 22021
  2. 52022
  3. 52023
  4. 92024
  5. 92025
  6. 62026

What FDA writes when it cites it

The finding headings that cite 21 CFR 1271.10 most often, as written in the letters.

  • 1 letterEVO HYBRID™ fails to meet the minimal manipulation criterion set forth in 21 CFR 1271.10(a)(1) and defined for structural tissue in 21 CFR 1271.3(f)(1) because the umbilical cord and amniotic membrane undergo processing…
  • 1 letterFurthermore, your SVF product fails to meet the minimal manipulation criterion set forth in 21 CFR 1271.10(a)(1) and defined for structural tissue in 21 CFR 1271.3(f)(1). Adipose tissue is typically defined as a…
  • 1 letterOn your website, https://innatehealthcare.org, you provide the following statements: - "At Innate Healthcare Institute, we combine an effective blend of integrative medicine and regenerative stem cell medicine, treating…

The regulation

Read the text of 21 CFR 1271.10 (eCFR, as of Sep 1, 2026)

(a) An HCT/P is regulated solely under section 361 of the PHS Act and the regulations in this part if it meets all of the following criteria:

(1) The HCT/P is minimally manipulated;

(2) The HCT/P is intended for homologous use only, as reflected by the labeling, advertising, or other indications of the manufacturer's objective intent;

(3) The manufacture of the HCT/P does not involve the combination of the cells or tissues with another article, except for water, crystalloids, or a sterilizing, preserving, or storage agent, provided that the addition of water, crystalloids, or the sterilizing, preserving, or storage agent does not raise new clinical safety concerns with respect to the HCT/P; and

(4) Either:

(i) The HCT/P does not have a systemic effect and is not dependent upon the metabolic activity of living cells for its primary function; or

(ii) The HCT/P has a systemic effect or is dependent upon the metabolic activity of living cells for its primary function, and:

(a) Is for autologous use;

(b) Is for allogeneic use in a first-degree or second-degree blood relative; or

(c) Is for reproductive use.

(b) If you are a domestic or foreign establishment that manufactures an HCT/P described in paragraph (a) of this section:

(1) You must register with FDA;

(2) You must submit to FDA a list of each HCT/P manufactured; and

(3) You must comply with the other requirements contained in this part.

[66 FR 5466, Jan. 19, 2001, as amended at 69 FR 68681, Nov. 24, 2004]

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 1271.10.

Latest letters citing it

The 3 letters citing 21 CFR 1271.10 that FDA posted most recently.

See the 36 letters citing 21 CFR 1271.10 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.