Drugs

Shantou Qiwei Industry Co., LTD

FDA issued a warning letter to Shantou Qiwei Industry Co., LTD (Shantou Shi, Guangdong Sheng, China) on Jun 2, 2026, citing 21 CFR 211.84, 21 CFR 211.22 and 21 CFR 211.160. Subject: CGMP, OTC Finished Pharmaceuticals, Adulterated.

From the letter: “Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality (21 CFR 211.84(d)(1) and 21 CFR 211.84(d)(2)).”

Shantou Shi, Guangdong Sheng, ChinaIssued Jun 2, 2026Posted Jun 9, 2026No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
2 findings · 2 issue types
Response due
Not stated in the letter
FDA asks for
7 actions
Named as possible actions
Refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Laboratory controls & testing · 21 CFR 211.84(d)(1), 21 CFR 211.84(d)(2)The firm failed to test talc components for identity, purity, strength, and quality, including asbestos testing, and failed to validate supplier COA reliability.
Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality (21 CFR 211.84(d)(1) and 21 CFR 211.84(d)(2)).
02Quality unit & oversight · 21 CFR 211.22The quality unit failed to ensure scientifically sound specifications for talc, including absence of asbestos, and approved deficient specifications.
Your firm’s quality control unit failed to exercise its responsibility to ensure drug products are manufactured in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).

What FDA requested

  • Identity, assay and impurity test results from testing retains for all lots of talc (drug component) used in the manufacture of your drug products. Alternatively, if a retain of a component lot is unavailable, perform retain sample testing of all implicated finished drug product batches for asbestos.
  • A description of how you will test each component lot for conformity with all appropriate written specifications for identity, purity, strength, and quality. If you intend to accept any results from your supplier’s COA instead of testing each component lot for strength, quality, and purity, specify how you will establish the reliability of your supplier’s results through initial validation as well as periodic revalidation. In addition, include a commitment to always conduct at least one specific identity test for each incoming component lot.
  • A full risk assessment for drug products that are within expiry which contain any ingredient at risk for asbestos contamination. Take prompt and appropriate actions to determine the safety of all lots of the component(s) and any related drug product that could contain asbestos. Appropriate actions could include customer notifications and drug product recalls for any contaminated lots.
  • The chemical quality control specifications you use to evaluate each incoming lot of drug component to determine acceptability for use in manufacturing.
  • A gap analysis for specifications for drug components (active and inactive) between your current specifications and test procedures against the United States Pharmacopeia (USP), where applicable. Based on your gap analysis, provide a comprehensive plan for conformance of your drug component specifications and testing to USP standards, where applicable.
  • A summary of results obtained from testing all components to evaluate the reliability of the COA from each component manufacturer. Include your standard operating procedure that describes this COA validation program.
  • A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to: A determination of whether procedures used by your firm are robust and appropriate; Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices; A complete and final review of representative batches within expiry and their related information before the QU disposition decision.

FDA Warning Letter

42 paragraphs · 5 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedJune 2, 2026
AddressedDear Mr. Kunjiang

1Introduction

4 paragraphs

Your facility was registered with the United States Food and Drug Administration (FDA) as a manufacturer of over-the-counter (OTC) drug products. FDA has reviewed the records you submitted in response to our August 14, 2025 request for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Shantou Qiwei Industry Co., LTD, FEI 3006784241, at Qiwei Building, Yingbinguan, Xiashan, Chaonan District, Shantou Guangdong.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your response to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) (21 U.S.C. 351(a)(2)(B)).

Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:

21. Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality (21 CFR 211.84(d)(1) and 21 CFR 211.84(d)(2)).

18 paragraphs

Your firm manufactures (b)(4), an OTC (b)(4) drug product labeled to contain the active drug ingredients (b)(4). This drug product is also labeled and formulated to contain the inactive ingredient talc. Both talc and asbestos are naturally occurring minerals that may be found in close proximity in the earth. Asbestos is a potential contaminant in talc and is a known human carcinogen when inhaled.1,2 Your (b)(4) drug product, (b)(4), is considered a higher-risk drug as it pertains to patient safety regarding asbestos contamination of talc due to the risk of inadvertent inhalation.

You have not demonstrated that you appropriately tested incoming talc-containing drug components used in the manufacture of your (b)(4) drug products for identity, purity, strength, and quality. In response to our 704(a)(4) request, you indicate that you did not perform testing for asbestos in talc, and our review found that you do not conduct identity testing on talc-containing drug components prior to use in the manufacture of your drug products.

You also failed to provide records indicating that you established the reliability of your supplier’s analyses through appropriate validation of the supplier’s test results. Although 21 CFR 211.84(d)(2) provides for some reliance on a certificate of analysis (COA) from the supplier of the component, such reliance is permissible only if the drug product manufacturer establishes the reliability of the supplier’s test results through appropriate validation of the test results at appropriate intervals. Without adequate testing, you lack scientific evidence that the components conform to appropriate specifications prior to use in the manufacture of your drug products.

As a manufacturer, you have a responsibility to sample, test, and examine, as appropriate, drug components before use in production to ensure acceptable specifications for identity, strength, quality, and purity are met. Because you have not performed appropriate testing that detects asbestos in your talc components, among other things, you failed to assure the acceptability of these drug components for use in manufacture of your drug products.

In response to this letter, provide:

Identity, assay and impurity test results from testing retains for all lots of talc (drug component) used in the manufacture of your drug products. Alternatively, if a retain of a component lot is unavailable, perform retain sample testing of all implicated finished drug product batches for asbestos. Provide this information within 30 calendar days of the date of this letter.

A description of how you will test each component lot for conformity with all appropriate written specifications for identity, purity, strength, and quality. If you intend to accept any results from your supplier’s COA instead of testing each component lot for strength, quality, and purity, specify how you will establish the reliability of your supplier’s results through initial validation as well as periodic revalidation. In addition, include a commitment to always conduct at least one specific identity test for each incoming component lot.

A full risk assessment for drug products that are within expiry which contain any ingredient at risk for asbestos contamination. Take prompt and appropriate actions to determine the safety of all lots of the component(s) and any related drug product that could contain asbestos. Appropriate actions could include customer notifications and drug product recalls for any contaminated lots.

The chemical quality control specifications you use to evaluate each incoming lot of drug component to determine acceptability for use in manufacturing.

A gap analysis for specifications for drug components (active and inactive) between your current specifications and test procedures against the United States Pharmacopeia (USP), where applicable. Based on your gap analysis, provide a comprehensive plan for conformance of your drug component specifications and testing to USP standards, where applicable.

A summary of results obtained from testing all components to evaluate the reliability of the COA from each component manufacturer. Include your standard operating procedure that describes this COA validation program.

2. Your firm’s quality control unit failed to exercise its responsibility to ensure drug products are manufactured in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).

Your quality unit (QU) did not effectively exercise its responsibility to ensure the acceptability of your drug components. For example, your QU did not ensure that your test procedures and specifications for talc are scientifically sound and appropriate (see 21 CFR 211.160(b)). The current USP talc monograph could be used to meet this requirement for talc; however, specifications for your talc-containing components failed to include testing for assay and multiple impurities (e.g., limits of (b)(4)). Notably, you failed to have a specification that includes a test for the absence of asbestos. Your QU approved and accepted talc for use in drug manufacturing with deficient specifications.

Your QU is responsible for fully exercising its authority and responsibilities, including responsibility for approving or rejecting all procedures or specifications impacting the identity, strength, quality, and purity of the drug product. Your firm’s quality systems are inadequate. See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations, for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

In response to this letter, provide a comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to:

A determination of whether procedures used by your firm are robust and appropriate

Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices

A complete and final review of representative batches within expiry and their related information before the QU disposition decision

3Quality Specifications Regarding Talc

1 paragraph

Talc is a USP article, whose specification can be found in the current USP talc monograph. As mentioned above, the specific test for asbestos is included in the talc monograph. Be advised that drugs including components, such as talc, that are recognized in the USP are generally required to meet the current applicable USP monograph under section 501(b) of the FD&C Act. FDA reviewed your specifications for talc-containing components and they are incomplete when compared to the current USP specification. We note that the USP has recently revised its monograph for talc which includes updated technical requirements for asbestos testing in talc and is currently scheduled to be official in June 2026.

4Use of Contract Manufacturers

2 paragraphs

Drugs must be manufactured in conformance with CGMP. FDA is aware that many drug manufacturers use independent contractors such as production facilities, testing laboratories, packagers, and labelers. FDA regards contractors as extensions of the manufacturer.

You are responsible for the quality of your drugs regardless of agreements in place with your contract facility. You are required to ensure that drugs are made in accordance with section 501(a)(2)(B) of the FD&C Act to ensure safety, identity, strength, quality, and purity. See FDA’s guidance document Contract Manufacturing Arrangements for Drugs: Quality Agreements at https://www.fda.gov/media/86193/download.

5Conclusion

5 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations for preventing their recurrence or the occurrence of other violations.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect to verify that you have completed corrective actions to any violations.

Failure to address any violations may also result in the FDA refusing admission of articles manufactured at Shantou Qiwei Industry Co., LTD, Qiwei Building, Yingbinguan, Xiashan, Chaonan District, Shantou Guangdong into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission, in that the methods and controls used in their manufacture do not appear to conform to CGMP within the meaning of section 501(a)(2)(B) of the FD&C Act, 21 U.S.C. 351(a)(2)(B).

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion. If you have information that you believe demonstrates that your products are not in violation of the FD&C Act and FDA regulations, include that information for our consideration.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3006784241 and ATTN: Nancy Espinal.

Sincerely,/S/

Francis GodwinDirectorOffice of Manufacturing QualityOffice of ComplianceCenter for Drug Evaluation and Research

_____________________________

1 https://www.cancer.gov/about-cancer/causes-prevention/risk/substances/asbestos

2 https://www.atsdr.cdc.gov/asbestos/health-effects/

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Shantou Shi, Guangdong Sheng, China
Letter posted date
Jun 9, 2026
Letter issue date
Jun 2, 2026
Addressed to
General Manager
Inspection dates
Not recorded
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,665 words · 7 recorded redactions
Published status
No published close-out
FDA reference
320-26-90
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.