Drugs

Pine Pharmaceuticals, LLC

FDA issued a warning letter to Pine Pharmaceuticals, LLC (Tonawanda, NY, United States) on Aug 7, 2026, citing 21 CFR 211.192, 21 CFR 211.113, 21 CFR 211.25, 21 CFR 211.103 and 3 more regulations. Subject: Compounding Pharmacy, Adulterated Drug Products.

From the letter: “Your firm did not disinfect materials during transfer from the ISO 7 cleanroom into the ISO 5 hood.”

Tonawanda, NY, United StatesIssued Aug 7, 2026Posted Oct 6, 2026No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
15 findings · 5 issue types
Response due
Fifteen (15) working days of receipt
FDA asks for
7 actions
Named as possible actions
Seizure, injunction
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Sterility & aseptic processingOperators failed to sanitize materials, equipment, and hands before entering the ISO 5 critical area, and sleeves were not sanitized after contact with ISO 7 surfaces.
Your firm did not disinfect materials during transfer from the ISO 7 cleanroom into the ISO 5 hood. Specifically, operators failed to sanitize materials, equipment, and hands prior to introducing them into the ISO 5 critical area during the production of drug products intended to be sterile. Furthermore, an operator rested their sleeved arms on ergonomic support bars attached to the ISO 5 hood (located in the ISO 7 background area) and subsequently extended their sleeved arms into the ISO 5 critical area without first sanitizing their sleeves.
02Sterility & aseptic processingRoutine environmental monitoring omits high-touch staging trays with difficult-to-clean designs, failing to capture data representative of aseptic production conditions.
Your environmental monitoring program lacks adequate routine environmental monitoring that captures data representative of aseptic production conditions. Specifically, your firm does not perform routine environmental monitoring of high-touch staging trays ((b)(4)) that are manually handled by gloved operators to stage materials, including final container closures for drug products intended to be sterile, prior to placement into the ISO 5 classified area. These trays have a difficult-to-clean (b)(4) design.
03Investigations & OOS · 21 CFR 211.192The firm failed to thoroughly investigate batch discrepancies or failures to meet specifications, as required by 21 CFR 211.192.
Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed [21 CFR 211.192].
04Sterility & aseptic processing · 21 CFR 211.113(b)The firm failed to establish and follow written procedures to prevent microbiological contamination of sterile drug products, including validation of aseptic and sterilization processes.
Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes [21 CFR 211.113(b)].
05Other · 21 CFR 211.25(a)The firm failed to ensure personnel had adequate education, training, and experience to perform their assigned functions.
Your firm failed to ensure that each person engaged in the manufacture, processing, packing, or holding of a drug product has the education, training, and experience, or any combination thereof, to enable that person to perform his or her assigned functions [21 CFR 211.25(a)].
06Production & process controls · 21 CFR 211.103The firm failed to determine actual yields, allowed excessive rejects without investigation, misclassified particulate matter as minor defects, and lacked criteria for cosmetic defects.
Your firm failed to determine actual yield and percentages of theoretical yield at the conclusion of each appropriate phase of manufacturing, processing, packaging, or holding of the drug product [21 CFR 211.103]. Specifically, in addition to the deficiencies noted in the visual inspection reject rate calculations, our review of the data collected during the inspection revealed that the acceptable yield range established in your batch records permits yields as low as (b)(4), allowing up to (b)(4) of a batch to be rejected without triggering an investigation, yet the batch can still be released for distribution. Furthermore, although (b)(4) meets the definition of particulate matter as “mobile undissolved particles, other than air bubbles, unintentionally present in solutions” in SOP-061 (Visual Inspection Finished Product, Rev. 23), it was classified as a “minor” defect in ISSUE-2025-0011, without scientific justification or a clear procedural basis in SOP-061. By classifying (b)(4) as a minor defect rather than as particulate matter, (b)(4) rejects are counted only as part of the minor reject rate limit, bypassing both the major defect category trigger and the separate particulate category trigger entirely. Additionally, certain “cosmetic” defects are allowed to be returned to the batch, despite SOP-061 containing no definition, criteria, or examples of what constitutes a “cosmetic” defect, nor does it specify which cosmetic defect may be returned to the batch and which must be rejected.
07Production & process controls · 21 CFR 211.100(a)The firm failed to establish written production and process control procedures to assure drug identity, strength, quality, and purity.
Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess [21 CFR 211.100(a)].
08Investigations & OOSThe firm's response to the particulate complaint lacked root-cause determination, reconciliation, and corrective actions, and training evidence was not provided.
Your response fails to address the specific deficiencies in the cited investigations and non-conformances. For the particulate complaint (COMP-2025-0005), your firm did not determine root cause for the confirmed cellulose particles or translucent fibers found in the returned vials or the retain sample, reconcile the particulate finding in the retain sample with the multiple particulates observed in the returned vials, or implement corrective actions for the visual inspection failure that allowed particulates to reach distributed product. You classified cellulose as an “intrinsic” particle without scientific justification, despite potential sources (e.g., cleaning wipes) indicating extrinsic contamination. Your response does not clearly commit to identifying and characterizing all observed particulates (including fibers and residues) in future investigations, nor does it define when such identification is required. Additionally, although you revised POL-030 (Product Complaint Handling) and implemented a training checkpoint, you did not provide evidence that the training was completed and did not establish a defined effectiveness verification plan for these corrective actions.
09Investigations & OOSThe firm relied on retrospective risk assessments and reinspection instead of thorough root-cause investigations for batches exceeding critical defect limits.
For the batches released despite exceeding critical defect limits, your responses rely on retrospective risk assessments, passing targeted/second 100% reinspection and (b)(4) AQL without thorough root-cause investigations or (b)(4) process corrections for recurring defects (e.g., dislodged caps, partially crimped seals, particulates). These risk assessments are outcome-based, focusing primarily on the absence of complaints or adverse events rather than evaluating the adequacy of your production and inspection controls. Furthermore, lot disposition for batches exceeding the (b)(4) critical reject rate was contingent on the outcome of a pending risk analysis (ISSUE-2025-0008) rather than on a completed investigation and upstream correction, indicating that risk assessment is being used as a substitute for corrective action rather than a complement to it. You also provided no scientific justification for limiting reinspections to preselected defect types rather than conducting a comprehensive 100% visual inspection across all potential defects, and you provided no evidence that CAPA-2025-0017 has been completed. This pattern of relying on reinspection and risk review to achieve passing results, without addressing underlying process failures, fails to demonstrate that the root causes of these defects have been identified, addressed, or controlled.
10Sterility & aseptic processingThe firm's response downplayed aseptic technique failures as isolated, but data showed widespread non-adherence by one operator across many batches.
Your response concludes that the observed aseptic technique failures were isolated to one operator and posed no product impact, with the risk declared low based primarily on passing environmental monitoring and sterility test results. However, your own batch review data (Tables 1 and 2 in ISSUE-2025-0006) demonstrates a widespread pattern of non-adherence by that operator across (b)(4) reviewed batches, with (b)(4) disinfection adherence to SOP-299 at only 11% and (b)(4) disinfection adherence at 0%.
11Sterility & aseptic processingThe firm's reliance on environmental monitoring and sterility tests is insufficient to address repeated aseptic technique failures, and the 'closed' process claim is unsupported.
Reliance on passing environmental monitoring and sterility test results does not adequately address the significant risk created by these repeated failures to follow basic aseptic techniques, including inadequate sanitization of materials and equipment transferred from the ISO 7 area into the ISO 5 hood during production of drug products intended to be sterile. This approach is scientifically insufficient because microbial contamination does not spread uniformly, and limited environmental monitoring and finished product sterility testing cannot reliably detect low-probability contamination events from consistent (b)(4) and (b)(4) lapses. Furthermore, your claim that the process is “closed” is not supported, as aseptic operations occur in ISO 5 hoods with routine interventions, making operator technique a primary sterility assurance control.
12Sterility & aseptic processingThe firm provided no documentation to support claims about other operators, and repeated deviations went undetected, raising concerns about oversight and quality controls.
Although you stated that similar deficiencies do not exist with other operators, you provided no supporting documentation (e.g., audit reports, video reviews, or Manufacturing Quality Assurance (MQA) records) to support this claim. You also did not provide the operator removal record (AI-2025-0524), the revised SOPs under CAPA-2025-0015, or a defined effectiveness verification plan. The repeated nature of these deviations by the same operator, going undetected and uncorrected over an extended period, raises serious concerns about the effectiveness of your routine oversight, training reinforcement, and overall quality system controls.
13Sterility & aseptic processingThe firm failed to address hand sanitization deficiencies and did not explain why deviations went undetected, a repeat deficiency from prior inspections.
The failures to sanitize or change gloves and sleeves after contact with non-sterile ISO 7 surfaces, and the failure to sanitize materials and equipment transferred from ISO 7 into the ISO 5 area, are not minor risks. They constitute insanitary conditions which can lead to contamination of products intended to be sterile and serious adverse events. Your response also fails to explain why these deviations went undetected for so long and does not address the specific hand sanitization deficiencies noted in the observation, including incomplete coverage of the backs of the hands and interdigital spaces and failure to meet the required (b)(4) duration as per your SOP-299 (Cleanroom Behavior and Aseptic Technique Procedure, Rev. 04). This is a repeat deficiency from the FDA inspections conducted in May 2021, September 2023, and September 2024.
14Quality unit & oversightThe firm failed to manage a significant change to visual inspector qualification SOP through formal change control and did not perform root-cause analysis.
Your response states that you conducted a historical review of qualification records and provided additional training for visual inspectors. However, you failed to manage the significant change to SOP-155, Training and Qualification of Qualified Visual Inspectors for Compounded Products, Rev. 09 (which introduced immediate failure of a visual inspector for missing any critical defect) through formal change control or a timely requalification plan for previously qualified inspectors that did not meet the new standard. You did not perform a root-cause analysis for why inspectors continued performing critical visual inspections for approximately three months after the SOP revision without meeting the new standard. Although you dispute the specific example with visual inspector (b)(6), (b)(7), you provided no documentation reconciling the answer key discrepancy or addressing the violation of performing (b)(4) qualification assessments in (b)(4). You also submitted no evidence that all impacted inspectors have been removed from relevant tasks or successfully requalified under the revised criteria. In addition, you have not committed to managing future significant changes to qualification procedures through formal change control. CAPA-2025-0014 remains pending with no supporting documentation.
15Production & process controlsThe firm did not open formal investigations for six batches exceeding reject rate thresholds, and updates to SOP-061 remain incomplete.
Your response states that you reviewed (b)(4) batches and implemented PLANDEV-2025-0027 to include all rejected units (confirmed and unconfirmed) in reject rate calculations. Although you identified six batches that would have exceeded thresholds when using actual reject rates, you did not demonstrate that formal investigations were opened for these batches. In addition, the permanent updates to SOP-061 (Visual Inspection Finished Product, Rev. 23) and the electronic batch record remain incomplete, with no firm completion dates or effectiveness verification plan. You also did not address the specific Diltiazem HCl lot 83709 example discussed during the inspection close-out. This is a repeat deficiency from the FDA inspection conducted in September 2024.

What FDA requested

  • Data demonstrating the effectiveness of (b)(4) for cleaning the current trays, a risk-based rationale for sampling only (b)(4) when (b)(4) bins are used per lot, justification for the chosen sampling site, confirmation that tray sampling will be permanently incorporated into routine procedure MWA-041, a validation protocol for the planned (b)(4) trays, and a defined plan to verify the effectiveness of the interim tray sampling program
  • Evidence that training was completed and a defined effectiveness verification plan for corrective actions related to POL-030
  • Root-cause analysis for the particulate complaint, reconciliation of particulate findings, and corrective actions for visual inspection failures
  • Documentation supporting the claim that similar deficiencies do not exist with other operators, the operator removal record (AI-2025-0524), revised SOPs under CAPA-2025-0015, and a defined effectiveness verification plan
  • Documentation reconciling the answer key discrepancy and addressing the violation of performing (b)(4) qualification assessments in (b)(4), evidence that all impacted inspectors have been removed or requalified, and commitment to manage future significant changes through formal change control
  • Demonstration that formal investigations were opened for the six batches that would have exceeded thresholds, completion dates and effectiveness verification plan for SOP-061 updates, and addressing the Diltiazem HCl lot 83709 example
  • Root-cause analysis for undefined critical process parameters, supporting documentation for PLANDEV-2025-0028, revised master production records or executed batch record examples, and a completion date and detailed validation plan for CAPA-2025-0013

FDA Warning Letter

46 paragraphs · 6 sections

Text as published on FDA.gov, retrieved Nov 3, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedAugust 7, 2026
AddressedDear Dr. Muto

1Introduction

2 paragraphs

You registered your facility with the U.S. Food and Drug Administration (FDA) as an outsourcing facility under section 503B of the Federal Food, Drug, and Cosmetic Act (FDCA) [21 U.S.C. § 353b]1 on March 9, 2018, and most recently on November 19, 2025. From November 4, 2025, to November 14, 2025, FDA investigators inspected your facility, Pine Pharmaceuticals, LLC located at 355 Riverwalk Parkway, Tonawanda, NY 14150. During the inspection, the investigators collected evidence indicating serious deficiencies in your practices for producing drug products which put patients at risk.

FDA issued a Form FDA 483 to your facility on November 14, 2025. We reviewed your December 8, 2025, response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence. Based on this inspection, it appears you produced drugs that violate the FDCA.

2A. Compounded Drug Products under the FDCA

2 paragraphs

Under section 503B(b) of the FDCA, a compounder can register as an outsourcing facility with FDA. Drug products compounded by or under the direct supervision of a licensed pharmacist in an outsourcing facility qualify for exemptions from the drug approval requirements in section 505 of the FDCA [21 U.S.C. § 355(a)], the requirement in section 502(f)(1) of the FDCA [21 U.S.C. § 352(f)(1)] that labeling bear adequate directions for use and the Drug Supply Chain Security Act requirements in section 582 of the FDCA [21 U.S.C. § 360eee-1] if the conditions in section 503B of the FDCA are met.

An outsourcing facility, which is defined in section 503B(d)(4) of the FDCA [21 U.S.C. § 353b(d)(4)], is a facility at one geographic location or address that — (i) is engaged in the compounding of sterile drugs; (ii) has elected to register as an outsourcing facility; and (iii) complies with all of the requirements of this section. Outsourcing facilities must comply with other applicable provisions of the FDCA, including section 501(a)(2)(B) [21 U.S.C. § 351(a)(2)(B)], regarding current good manufacturing practice (CGMP), and section 501(a)(2)(A) [21 U.S.C. § 351(a)(2)(A)], regarding insanitary conditions. Generally, CGMP requirements for the preparation of drug products are established in Title 21 of the Code of Federal Regulations (CFR) parts 210 and 211.

3B. Violations of the FDCA

0 paragraphs

4Adulterated Drug Products

11 paragraphs

FDA investigators collected evidence indicating that drug products intended or expected to be sterile were prepared, packed, or held under insanitary conditions, whereby they may have become contaminated with filth or rendered injurious to health, causing your drug products to be adulterated under section 501(a)(2)(A) of the FDCA. For example, the investigators collected evidence indicating that:

1. Your firm did not disinfect materials during transfer from the ISO 7 cleanroom into the ISO 5 hood. Specifically, operators failed to sanitize materials, equipment, and hands prior to introducing them into the ISO 5 critical area during the production of drug products intended to be sterile. Furthermore, an operator rested their sleeved arms on ergonomic support bars attached to the ISO 5 hood (located in the ISO 7 background area) and subsequently extended their sleeved arms into the ISO 5 critical area without first sanitizing their sleeves.

2. Your environmental monitoring program lacks adequate routine environmental monitoring that captures data representative of aseptic production conditions. Specifically, your firm does not perform routine environmental monitoring of high-touch staging trays ((b)(4)) that are manually handled by gloved operators to stage materials, including final container closures for drug products intended to be sterile, prior to placement into the ISO 5 classified area. These trays have a difficult-to-clean (b)(4) design.

FDA investigators also collected evidence indicating CGMP violations at your facility, that caused your drug products to be adulterated within the meaning of section 501(a)(2)(B) of the FDCA. The violations include, for example:

1. Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed [21 CFR 211.192].

2. Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes [21 CFR 211.113(b)].

3. Your firm failed to ensure that each person engaged in the manufacture, processing, packing, or holding of a drug product has the education, training, and experience, or any combination thereof, to enable that person to perform his or her assigned functions [21 CFR 211.25(a)].

4. Your firm failed to determine actual yield and percentages of theoretical yield at the conclusion of each appropriate phase of manufacturing, processing, packaging, or holding of the drug product [21 CFR 211.103]. Specifically, in addition to the deficiencies noted in the visual inspection reject rate calculations, our review of the data collected during the inspection revealed that the acceptable yield range established in your batch records permits yields as low as (b)(4), allowing up to (b)(4) of a batch to be rejected without triggering an investigation, yet the batch can still be released for distribution. Furthermore, although (b)(4) meets the definition of particulate matter as “mobile undissolved particles, other than air bubbles, unintentionally present in solutions” in SOP-061 (Visual Inspection Finished Product, Rev. 23), it was classified as a “minor” defect in ISSUE-2025-0011, without scientific justification or a clear procedural basis in SOP-061. By classifying (b)(4) as a minor defect rather than as particulate matter, (b)(4) rejects are counted only as part of the minor reject rate limit, bypassing both the major defect category trigger and the separate particulate category trigger entirely. Additionally, certain “cosmetic” defects are allowed to be returned to the batch, despite SOP-061 containing no definition, criteria, or examples of what constitutes a “cosmetic” defect, nor does it specify which cosmetic defect may be returned to the batch and which must be rejected.

5. Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess [21 CFR 211.100(a)].

Outsourcing facilities must comply with CGMP requirements under section 501(a)(2)(B) of the FDCA. FDA’s regulations regarding CGMP requirements for the preparation of drug products have been established in 21 CFR parts 210 and 211. FDA intends to promulgate more specific CGMP regulations for outsourcing facilities. FDA has issued a revised draft guidance, Current Good Manufacturing Practice — Guidance for Human Drug Compounding Outsourcing Facilities under Section 503B of the FD&C Act. This draft guidance, when finalized, will describe FDA’s expectations regarding outsourcing facilities and the CGMP requirements in 21 CFR parts 210 and 211 until more specific CGMP regulations for outsourcing facilities are promulgated.

Under section 301(a) of the FDCA [21 U.S.C. § 331(a)], the introduction or delivery for introduction into interstate commerce of any drug that is adulterated is a prohibited act. Further, it is a prohibited act under section 301(k) of the FDCA [21 U.S.C. § 331(k)] to do any act with respect to a drug, if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being adulterated.

5C. Corrective Actions

15 paragraphs

We have reviewed your firm’s responses to the Form FDA 483. We are unable to fully evaluate some of your corrective actions due to lack of adequate supporting documentation:

1. Your response states that you implemented post-production surface sampling of (b)(4) per FID 131 batch (PLANDEV-2025-0021) and plan to transition to (b)(4) trays by the end of Q2 2026. While these actions are intended to address the observed deficiency, we are unable to determine their adequacy due to insufficient supporting documentation and scientific justification. You did not provide data demonstrating the effectiveness of (b)(4) for cleaning the current trays (particularly the difficult-to-clean (b)(4)), a risk-based rationale for sampling only (b)(4) when (b)(4) bins are used per lot, justification for the chosen sampling site, confirmation that tray sampling will be permanently incorporated into routine procedure MWA-041, a validation protocol for the planned (b)(4) trays, or a defined plan to verify the effectiveness of the interim tray sampling program.

Some of your corrective actions appear deficient:

1. Your response fails to address the specific deficiencies in the cited investigations and non-conformances. For the particulate complaint (COMP-2025-0005), your firm did not determine root cause for the confirmed cellulose particles or translucent fibers found in the returned vials or the retain sample, reconcile the particulate finding in the retain sample with the multiple particulates observed in the returned vials, or implement corrective actions for the visual inspection failure that allowed particulates to reach distributed product. You classified cellulose as an “intrinsic” particle without scientific justification, despite potential sources (e.g., cleaning wipes) indicating extrinsic contamination. Your response does not clearly commit to identifying and characterizing all observed particulates (including fibers and residues) in future investigations, nor does it define when such identification is required. Additionally, although you revised POL-030 (Product Complaint Handling) and implemented a training checkpoint, you did not provide evidence that the training was completed and did not establish a defined effectiveness verification plan for these corrective actions.

For the batches released despite exceeding critical defect limits, your responses rely on retrospective risk assessments, passing targeted/second 100% reinspection and (b)(4) AQL without thorough root-cause investigations or (b)(4) process corrections for recurring defects (e.g., dislodged caps, partially crimped seals, particulates). These risk assessments are outcome-based, focusing primarily on the absence of complaints or adverse events rather than evaluating the adequacy of your production and inspection controls. Furthermore, lot disposition for batches exceeding the (b)(4) critical reject rate was contingent on the outcome of a pending risk analysis (ISSUE-2025-0008) rather than on a completed investigation and upstream correction, indicating that risk assessment is being used as a substitute for corrective action rather than a complement to it. You also provided no scientific justification for limiting reinspections to preselected defect types rather than conducting a comprehensive 100% visual inspection across all potential defects, and you provided no evidence that CAPA-2025-0017 has been completed. This pattern of relying on reinspection and risk review to achieve passing results, without addressing underlying process failures, fails to demonstrate that the root causes of these defects have been identified, addressed, or controlled.

2. Your response concludes that the observed aseptic technique failures were isolated to one operator and posed no product impact, with the risk declared low based primarily on passing environmental monitoring and sterility test results. However, your own batch review data (Tables 1 and 2 in ISSUE-2025-0006) demonstrates a widespread pattern of non-adherence by that operator across (b)(4) reviewed batches, with (b)(4) disinfection adherence to SOP-299 at only 11% and (b)(4) disinfection adherence at 0%.

Reliance on passing environmental monitoring and sterility test results does not adequately address the significant risk created by these repeated failures to follow basic aseptic techniques, including inadequate sanitization of materials and equipment transferred from the ISO 7 area into the ISO 5 hood during production of drug products intended to be sterile. This approach is scientifically insufficient because microbial contamination does not spread uniformly, and limited environmental monitoring and finished product sterility testing cannot reliably detect low-probability contamination events from consistent (b)(4) and (b)(4) lapses. Furthermore, your claim that the process is “closed” is not supported, as aseptic operations occur in ISO 5 hoods with routine interventions, making operator technique a primary sterility assurance control.

Although you stated that similar deficiencies do not exist with other operators, you provided no supporting documentation (e.g., audit reports, video reviews, or Manufacturing Quality Assurance (MQA) records) to support this claim. You also did not provide the operator removal record (AI-2025-0524), the revised SOPs under CAPA-2025-0015, or a defined effectiveness verification plan. The repeated nature of these deviations by the same operator, going undetected and uncorrected over an extended period, raises serious concerns about the effectiveness of your routine oversight, training reinforcement, and overall quality system controls.

The failures to sanitize or change gloves and sleeves after contact with non-sterile ISO 7 surfaces, and the failure to sanitize materials and equipment transferred from ISO 7 into the ISO 5 area, are not minor risks. They constitute insanitary conditions which can lead to contamination of products intended to be sterile and serious adverse events. Your response also fails to explain why these deviations went undetected for so long and does not address the specific hand sanitization deficiencies noted in the observation, including incomplete coverage of the backs of the hands and interdigital spaces and failure to meet the required (b)(4) duration as per your SOP-299 (Cleanroom Behavior and Aseptic Technique Procedure, Rev. 04). This is a repeat deficiency from the FDA inspections conducted in May 2021, September 2023, and September 2024.

3. Your response states that you conducted a historical review of qualification records and provided additional training for visual inspectors. However, you failed to manage the significant change to SOP-155, Training and Qualification of Qualified Visual Inspectors for Compounded Products, Rev. 09 (which introduced immediate failure of a visual inspector for missing any critical defect) through formal change control or a timely requalification plan for previously qualified inspectors that did not meet the new standard. You did not perform a root-cause analysis for why inspectors continued performing critical visual inspections for approximately three months after the SOP revision without meeting the new standard. Although you dispute the specific example with visual inspector (b)(6), (b)(7), you provided no documentation reconciling the answer key discrepancy or addressing the violation of performing (b)(4) qualification assessments in (b)(4). You also submitted no evidence that all impacted inspectors have been removed from relevant tasks or successfully requalified under the revised criteria. In addition, you have not committed to managing future significant changes to qualification procedures through formal change control. CAPA-2025-0014 remains pending with no supporting documentation.

4. Your response states that you reviewed (b)(4) batches and implemented PLANDEV-2025-0027 to include all rejected units (confirmed and unconfirmed) in reject rate calculations. Although you identified six batches that would have exceeded thresholds when using actual reject rates, you did not demonstrate that formal investigations were opened for these batches. In addition, the permanent updates to SOP-061 (Visual Inspection Finished Product, Rev. 23) and the electronic batch record remain incomplete, with no firm completion dates or effectiveness verification plan. You also did not address the specific Diltiazem HCl lot 83709 example discussed during the inspection close-out. This is a repeat deficiency from the FDA inspection conducted in September 2024.

5. Your response acknowledges the lack of validated mixing and (b)(4) parameters but treats full process validation (CAPA-2025-0013) as conditional, only to be prioritized if future potency variability or out of specification (OOS) events occur. You provided no root-cause analysis explaining why critical process parameters remained undefined and operator-dependent for an extended period despite a prior OOS investigation. You also submitted no supporting documentation for PLANDEV-2025-0028, no revised master production records or executed batch record examples showing the new parameters, and no completion date or detailed validation plan for CAPA-2025-0013.

In addition to the issues discussed above, you should note that CGMP requires the implementation of quality oversight and controls over the manufacture of drugs, including the safety of raw materials, materials used in drug manufacturing, and finished drug products. See section 501 of the FDCA. If you choose to contract with a laboratory to perform some functions required by CGMP, it is essential that you select a qualified contractor and that you maintain sufficient oversight of the contractor’s operations to ensure that it is fully CGMP compliant.

Regardless of whether you rely on a contract facility, you are responsible for assuring that drugs you produce are neither adulterated nor misbranded. [See 21 CFR 210.1(b), 21 CFR 200.10(b).]

FDA strongly recommends that your management undertake a comprehensive assessment of operations, including facility design, procedures, personnel, processes, maintenance, materials, and systems. In particular, this review should assess your aseptic processing operations. A third-party consultant with relevant sterile drug manufacturing expertise should assist you in conducting this comprehensive evaluation.

6D. Conclusion

4 paragraphs

The violations cited in this letter are not intended to be an all-inclusive statement of violations at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations.

You should take prompt action to address any violations. Failure to adequately address any violations may result in legal action without further notice, including, without limitation, seizure and injunction.

Response requested

Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps that you have taken to address any violations. Please include an explanation of each step being taken to prevent the recurrence of violations, as well as copies of related documentation. This letter notifies you of our concerns and provides you an opportunity to address them. If you believe your products are not in violation of the FDCA, include your reasoning and any supporting information for our consideration. If you cannot completely address this matter within fifteen (15) working days, state the reason for the delay and the time within which you will do so.

All correspondence should refer to the Warning Letter Number above (# 728537) and include a subject line that clearly identifies the submission as a Response to Warning Letter. If you have questions regarding the contents of this letter, please contact compoundinginspections@fda.hhs.gov.

Sincerely,/S/

Matthew J. LashActing DirectorOffice of Compounding Quality and ComplianceOffice of ComplianceCenter for Drug Evaluation and Research

_________________

1 See Pub. L. No. 113-54, § 102(a), 127 Stat. 587, 587-588 (2013).

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 10, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

21 CFR 211.25Personnel qualifications23letters cite it
6 letters issued this year vs 6 by the same date last year · +0%About 21 CFR 211.25 →
21 CFR 211.103Calculation of yield1letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 211.103 →
020210202202023020240202512026

Also cited: 21 CFR 210

Issue types

Investigations & OOSAI-assigned issue type202letters3findings here
49 letters issued this year vs 35 by the same date last year · +40%
OtherAI-assigned issue type140letters1finding here
25 letters issued this year vs 32 by the same date last year · -22%

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Tonawanda, NY, United States
Letter posted date
Oct 6, 2026
Letter issue date
Aug 7, 2026
Addressed to
Owner
Inspection dates
Nov 4, 2025 to Nov 14, 2025
Response window
15 working days after receipt of this letter
Read the source clause
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps that you have taken to address any violations.
Record length
2,943 words · 29 recorded redactions
Published status
No published close-out
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 20, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,711 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.