Drugs · Jun 18, 2025

Dynamic Blending Specialists, Inc.

3 extracted findings · 5 model-assigned issue types

FDA source excerpt, selected passage

Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals

Findings and supporting evidence

Model-assisted readings, not an exhaustive interpretation. Compare with the extracted source findings below.

Components & suppliers21 CFR 211.84(d)(1)

Failed to perform identity testing on each component lot and to validate supplier COA reliability.

Supporting FDA text
Source excerpt · automated text-match check

Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals

Components & suppliers

Failed to test glycerin shipments for identity including DEG/EG limit tests.

Supporting FDA text
Source excerpt · automated text-match check

You failed to adequately test each shipment of each lot of glycerin for identity, a component at higher risk for diethylene glycol (DEG) and ethylene glycol (EG) contamination.

Laboratory controls & testing21 CFR 211.160(b)

Sampling plans for drug products were not justified to represent entire batch quality.

Supporting FDA text
Source excerpt · automated text-match check

Your sampling plans prior to the release of your drug products are not sufficient to assure their quality.

Laboratory controls & testing

Failed to document adequate monitoring and testing of water system used in products.

Supporting FDA text
Source excerpt · automated text-match check

you were unable to provide documentation to demonstrate that your (b)(4) water system is adequately monitored and tested for conductivity or microbiology.

Records & data integrity

Scale calibration logs lacked unique identifiers and were loose pages.

Supporting FDA text
Source excerpt · automated text-match check

Your scale calibration logs consisted of loose pages printed without unique identifiers.

Records & data integrity

Could not provide non-conformance report because previous data system was not maintained.

Supporting FDA text
Source excerpt · automated text-match check

You could not provide a non-conformance (NC) report referenced in (b)(4) executed batch records because your previous NC data system was no longer maintained.

Records & data integrity

Shred bins with apparent CGMP records were located in manufacturing and warehouse areas.

Supporting FDA text
Source excerpt · automated text-match check

Shred bins containing what appeared to be CGMP records were located in your manufacturing and warehouse areas.

Records & data integrity

Water monitoring records stored on personal computer could not be provided.

Supporting FDA text
Source excerpt · automated text-match check

Water monitoring records stored on an employee’s personal computer could not be provided.

Stability & expiry

Could not provide data supporting labeled expiration dates of drug products.

Supporting FDA text
Source excerpt · automated text-match check

You could not provide data to support the labeled expiration date of drug products manufactured by your facility.

Labeling, claims & marketing

Marketed an unapproved new drug without an approved application.

Supporting FDA text
Source excerpt · automated text-match check

“(b)(4)” is an unapproved new drug introduced or delivered for introduction into interstate commerce in violation of sections 505(a) and 301(d) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 355(a) and 331(d).

Labeling, claims & marketing

Product misbranded because it does not comply with OTC marketing requirements.

Supporting FDA text
Source excerpt · automated text-match check

this product is misbranded under section 502(ee) of the FD&C Act, 21 U.S.C. 352(ee).

Findings extracted from the letter

Selected FDA passages, not the complete letter.

01
Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).
02
Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).
03
Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

What FDA requested

Model-assisted summary. Consult the letter for complete requests and conditions.

  • Describe component lot testing for identity, strength, quality, purity and COA reliability validation.
  • Commit to DEG/EG test results for high-risk component retains within 30 days.
  • Provide full risk assessment for products containing DEG/EG-risk ingredients and actions.
  • Provide chemical and microbiology specifications for incoming high-risk components.
  • Conduct independent review of material system and supplier qualification.
  • Summarize COA reliability test results and include COA validation SOP.
  • Summarize program for qualifying and overseeing contract testing facilities.
  • Provide comprehensive assessment and remediation plan for quality unit authority and documentation.

Sections and clauses cited

As cited in this historical letter, not a statement of current regulatory requirements.

Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.