21 CFR 862.9
Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act)
21 CFR 862.9 is the regulation titled “Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act)” in 21 CFR Part 862, Clinical Chemistry and Clinical Toxicology Devices. Since 2021, 1 FDA warning letter has cited it.
- Letters citing it
- 1 since 2021
- Jan 1 to Oct 30, 2026
- 0 against 1 on the same dates in 2025
- Most often cited with
- 21 CFR 806.10, in 1 letter
- Closed out
- 0% of these letters have a published close-out
Letters citing it, by year issued
It is a medical device letter. 2026 runs to Oct 30, 2026. Pick a year to see its letters.
- 02021
- 02022
- 02023
- 02024
- 12025
- 02026
The regulation
Read the text of 21 CFR 862.9 (eCFR, as of Sep 1, 2026)
The exemption from the requirement of premarket notification (section 510(k) of the act) for a generic type of class I or II device is only to the extent that the device has existing or reasonably foreseeable characteristics of commercially distributed devices within that generic type or, in the case of in vitro diagnostic devices, only to the extent that misdiagnosis as a result of using the device would not be associated with high morbidity or mortality. Accordingly, manufacturers of any commercially distributed class I or II device for which FDA has granted an exemption from the requirement of premarket notification must still submit a premarket notification to FDA before introducing or delivering for introduction into interstate commerce for commercial distribution the device when:
(a) The device is intended for a use different from the intended use of a legally marketed device in that generic type of device; e.g., the device is intended for a different medical purpose, or the device is intended for lay use where the former intended use was by health care professionals only;
(b) The modified device operates using a different fundamental scientific technology than a legally marketed device in that generic type of device; e.g., a surgical instrument cuts tissue with a laser beam rather than with a sharpened metal blade, or an in vitro diagnostic device detects or identifies infectious agents by using deoxyribonucleic acid (DNA) probe or nucleic acid hybridization technology rather than culture or immunoassay technology; or
(c) The device is an in vitro device that is intended:
(1) For use in the diagnosis, monitoring, or screening of neoplastic diseases with the exception of immunohistochemical devices;
(2) For use in screening or diagnosis of familial or acquired genetic disorders, including inborn errors of metabolism;
(3) For measuring an analyte that serves as a surrogate marker for screening, diagnosis, or monitoring life-threatening diseases such as acquired immune deficiency syndrome (AIDS), chronic or active hepatitis, tuberculosis, or myocardial infarction or to monitor therapy;
(4) For assessing the risk of cardiovascular diseases;
(5) For use in diabetes management;
(6) For identifying or inferring the identity of a microorganism directly from clinical material;
(7) For detection of antibodies to microorganisms other than immunoglobulin G (IgG) or IgG assays when the results are not qualitative, or are used to determine immunity, or the assay is intended for use in matrices other than serum or plasma;
(8) For noninvasive testing as defined in § 812.3(k) of this chapter; and
(9) For near patient testing (point of care).
[65 FR 2304, Jan. 14, 2000]
Text from eCFR as of Sep 1, 2026.
Cited alongside it
Regulations that appear in the same letters as 21 CFR 862.9.
Latest letters citing it
The letter citing 21 CFR 862.9 that FDA posted most recently.
See the letter citing 21 CFR 862.9 →Put this kind of reading to
work on your own records.
Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.
Counts include every citation in a letter, as the Letters filter does. How this database is built.