21 CFR Part 58 · Good Laboratory Practice for Nonclinical Laboratory Studies

21 CFR 58.190

Storage and retrieval of records and data

21 CFR 58.190 is the regulation titled “Storage and retrieval of records and data” in 21 CFR Part 58, Good Laboratory Practice for Nonclinical Laboratory Studies. Since 2021, 2 FDA warning letters have cited it.

Letters citing it
2 since 2021
Jan 1 to Oct 30, 2026
0 against 1 on the same dates in 2025
Most often cited with
21 CFR 58.130, in 2 letters
Closed out
50% of these letters have a published close-out
See the 2 letters citing 21 CFR 58.190 →

Letters citing it, by year issued

Most are medical device letters (1 of 2). 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 02021
  2. 12022
  3. 02023
  4. 02024
  5. 12025
  6. 02026

What FDA writes when it cites it

The finding headings that cite 21 CFR 58.190 most often, as written in the letters.

  • 1 letterFailure to provide for orderly storage and expedient retrieval of all raw data, documentation, protocols, specimens and interim and final reports [21 CFR 58.190(b)]

The regulation

Read the text of 21 CFR 58.190 (eCFR, as of Sep 1, 2026)

(a) All raw data, documentation, protocols, final reports, and specimens (except those specimens obtained from mutagenicity tests and wet specimens of blood, urine, feces, and biological fluids) generated as a result of a nonclinical laboratory study shall be retained.

(b) There shall be archives for orderly storage and expedient retrieval of all raw data, documentation, protocols, specimens, and interim and final reports. Conditions of storage shall minimize deterioration of the documents or specimens in accordance with the requirements for the time period of their retention and the nature of the documents or specimens. A testing facility may contract with commercial archives to provide a repository for all material to be retained. Raw data and specimens may be retained elsewhere provided that the archives have specific reference to those other locations.

(c) An individual shall be identified as responsible for the archives.

(d) Only authorized personnel shall enter the archives.

(e) Material retained or referred to in the archives shall be indexed to permit expedient retrieval.

[43 FR 60013, Dec. 22, 1978, as amended at 52 FR 33781, Sept. 4, 1987; 67 FR 9585, Mar. 4, 2002]

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 58.190.

Latest letters citing it

The 2 letters citing 21 CFR 58.190 that FDA posted most recently.

See the 2 letters citing 21 CFR 58.190 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.