21 CFR Part 212 · Current Good Manufacturing Practice for Positron Emission Tomography Drugs

21 CFR 212.60

What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?

21 CFR 212.60 is the regulation titled “What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?” in 21 CFR Part 212, Current Good Manufacturing Practice for Positron Emission Tomography Drugs. Since 2021, 1 FDA warning letter has cited it.

Letters citing it
1 since 2021
Jan 1 to Oct 30, 2026
0 against 0 on the same dates in 2025
Most often cited with
21 CFR 207.57, in 1 letter
Closed out
0% of these letters have a published close-out
See the letter citing 21 CFR 212.60 →

Letters citing it, by year issued

It is a drug letter. 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 02021
  2. 02022
  3. 02023
  4. 02024
  5. 12025
  6. 02026

What FDA writes when it cites it

The finding headings that cite 21 CFR 212.60 most often, as written in the letters.

  • 1 letterYour firm failed to have laboratory methods suitable for their intended use and sufficiently sensitive, specific, accurate, and reproducible (21 CFR 212.60)

The regulation

Read the text of 21 CFR 212.60 (eCFR, as of Sep 1, 2026)

(a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written procedures for the conduct of each test and for the documentation of the results.

(b) Specifications and standards. Each laboratory must have sampling and testing procedures designed to ensure that components, in-process materials, and PET drug products conform to appropriate standards, including established standards of identity, strength, quality, and purity.

(c) Analytical methods. Laboratory analytical methods must be suitable for their intended use and must be sufficiently sensitive, specific, accurate, and reproducible.

(d) Materials. The identity, purity, and quality of reagents, solutions, and supplies used in testing procedures must be adequately controlled. All solutions that you prepare must be properly labeled to show their identity and expiration date.

(e) Equipment. All equipment used to perform the testing must be suitable for its intended purposes and capable of producing valid results.

(f) Equipment maintenance. Each laboratory must have and follow written procedures to ensure that equipment is routinely calibrated, inspected, checked, and maintained, and that these activities are documented.

(g) Test records. Each laboratory performing tests related to the production of a PET drug must keep complete records of all tests performed to ensure compliance with established specifications and standards, including examinations and assays, as follows:

(1) A suitable identification of the sample received for testing.

(2) A description of each method used in the testing of the sample, a record of all calculations performed in connection with each test, and a statement of the weight or measurement of the sample used for each test.

(3) A complete record of all data obtained in the course of each test, including the date and time the test was conducted, and all graphs, charts, and spectra from laboratory instrumentation, properly identified to show the specific component, in-process material, or drug product for each lot tested.

(4) A statement of the results of tests and how the results compare with established acceptance criteria.

(5) The initials or signature of the person performing the test and the date on which the test was performed.

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 212.60.

Latest letters citing it

The letter citing 21 CFR 212.60 that FDA posted most recently.

See the letter citing 21 CFR 212.60 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.