21 CFR Part 211 · Current Good Manufacturing Practice for Finished Pharmaceuticals

21 CFR 211.110

Sampling and testing of in-process materials and drug products

21 CFR 211.110 is the regulation titled “Sampling and testing of in-process materials and drug products” in 21 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals. Since 2021, 11 FDA warning letters have cited it.

Letters citing it
11 since 2021
Jan 1 to Oct 30, 2026
2 against 3 on the same dates in 2025
Most often cited with
21 CFR 211.113, in 7 letters
Closed out
0% of these letters have a published close-out
See the 11 letters citing 21 CFR 211.110 →

Letters citing it, by year issued

Most are drug letters (9 of 11). 2026 runs to Oct 30, 2026. Pick a year to see its letters.

  1. 02021
  2. 12022
  3. 22023
  4. 32024
  5. 32025
  6. 22026

What FDA writes when it cites it

The finding headings that cite 21 CFR 211.110 most often, as written in the letters.

  • 3 lettersYour firm failed to establish and follow adequate control procedures to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the…
  • 1 letterFailure to establish written procedures for production and process control designed to assure that the drug products have the identity, strength, quality, and purity that they purport or are represented to possess [21…
  • 1 letterFailure to test in-process materials for identity, strength, quality, and purity, as appropriate, and approve or reject by the quality control unit, during the production process [21 CFR 211.110(c)]. For example, your…

The regulation

Read the text of 21 CFR 211.110 (eCFR, as of Sep 1, 2026)

(a) To assure batch uniformity and integrity of drug products, written procedures shall be established and followed that describe the in-process controls, and tests, or examinations to be conducted on appropriate samples of in-process materials of each batch. Such control procedures shall be established to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Such control procedures shall include, but are not limited to, the following, where appropriate:

(1) Tablet or capsule weight variation;

(2) Disintegration time;

(3) Adequacy of mixing to assure uniformity and homogeneity;

(4) Dissolution time and rate;

(5) Clarity, completeness, or pH of solutions.

(6) Bioburden testing.

(b) Valid in-process specifications for such characteristics shall be consistent with drug product final specifications and shall be derived from previous acceptable process average and process variability estimates where possible and determined by the application of suitable statistical procedures where appropriate. Examination and testing of samples shall assure that the drug product and in-process material conform to specifications.

(c) In-process materials shall be tested for identity, strength, quality, and purity as appropriate, and approved or rejected by the quality control unit, during the production process, e.g., at commencement or completion of significant phases or after storage for long periods.

(d) Rejected in-process materials shall be identified and controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

[43 FR 45077, Sept. 29, 1978, as amended at 73 FR 51932, Sept. 8, 2008]

Text from eCFR as of Sep 1, 2026.

Cited alongside it

Regulations that appear in the same letters as 21 CFR 211.110.

Latest letters citing it

The 3 letters citing 21 CFR 211.110 that FDA posted most recently.

See the 11 letters citing 21 CFR 211.110 →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Counts include every citation in a letter, as the Letters filter does. How this database is built.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.