21 CFR 111.365
What precautions must you take to prevent contamination?
21 CFR 111.365 is the regulation titled “What precautions must you take to prevent contamination?” in 21 CFR Part 111, Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements. Since 2021, 1 FDA warning letter has cited it.
- Letters citing it
- 1 since 2021
- Jan 1 to Oct 30, 2026
- 0 against 0 on the same dates in 2025
- Most often cited with
- 21 CFR 101.12, in 1 letter
- Closed out
- 0% of these letters have a published close-out
Letters citing it, by year issued
It is a drug letter. 2026 runs to Oct 30, 2026. Pick a year to see its letters.
- 02021
- 12022
- 02023
- 02024
- 02025
- 02026
The regulation
Read the text of 21 CFR 111.365 (eCFR, as of Sep 1, 2026)
You must take all the necessary precautions during the manufacture of a dietary supplement to prevent contamination of components or dietary supplements. These precautions include:
(a) Performing manufacturing operations under conditions and controls that protect against the potential for growth of microorganisms and the potential for contamination;
(b) Washing or cleaning components that contain soil or other contaminants;
(c) Using water that, at a minimum, complies with the applicable Federal, State, and local requirements and does not contaminate the dietary supplement when the water may become a component of the finished batch of dietary supplement;
(d) Performing chemical, microbiological, or other testing, as necessary to prevent the use of contaminated components;
(e) Sterilizing, pasteurizing, freezing, refrigerating, controlling hydrogen-ion concentration (pH), controlling humidity, controlling water activity (aw), or using any other effective means to remove, destroy, or prevent the growth of microorganisms and prevent decomposition;
(f) Holding components and dietary supplements that can support the rapid growth of microorganisms of public health significance in a manner that prevents the components and dietary supplements from becoming adulterated;
(g) Identifying and holding any components or dietary supplements, for which a material review and disposition decision is required, in a manner that protects components or dietary supplements that are not under a material review against contamination and mixups with those that are under a material review;
(h) Performing mechanical manufacturing steps (such as cutting, sorting, inspecting, shredding, drying, grinding, blending, and sifting) by any effective means to protect the dietary supplements against contamination, by, for example:
(1) Cleaning and sanitizing contact surfaces;
(2) Using temperature controls; and
(3) Using time controls.
(i) Using effective measures to protect against the inclusion of metal or other foreign material in components or dietary supplements, by, for example:
(1) Filters or strainers,
(2) Traps,
(3) Magnets, or
(4) Electronic metal detectors.
(j) Segregating and identifying all containers for a specific batch of dietary supplements to identify their contents and, when necessary, the phase of manufacturing; and
(k) Identifying all processing lines and major equipment used during manufacturing to indicate their contents, including the name of the dietary supplement and the specific batch or lot number and, when necessary, the phase of manufacturing.
Text from eCFR as of Sep 1, 2026.
Cited alongside it
Regulations that appear in the same letters as 21 CFR 111.365.
- 21 CFR 101.12Reference amounts customarily consumed per eating occasion1 letter cites both
- 21 CFR 101.15Food; prominence of required statements1 letter cites both
- 21 CFR 101.2Information panel of package form food1 letter cites both
- 21 CFR 101.3Identity labeling of food in packaged form1 letter cites both
- 21 CFR 101.36Nutrition labeling of dietary supplements1 letter cites both
- 21 CFR 101.4Food; designation of ingredients1 letter cites both
- 21 CFR 101.5Food; name and place of business of manufacturer, packer, or distributor1 letter cites both
- 21 CFR 101.7Declaration of net quantity of contents1 letter cites both
Latest letters citing it
The letter citing 21 CFR 111.365 that FDA posted most recently.
See the letter citing 21 CFR 111.365 →Put this kind of reading to
work on your own records.
Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.
Counts include every citation in a letter, as the Letters filter does. How this database is built.