Vita Pharmacy, LLC dba Talon Pharmacy of Boerne
FDA issued a warning letter to Vita Pharmacy, LLC dba Talon Pharmacy of Boerne (Austin, TX, United States) on Aug 29, 2022. Subject: Compounding Pharmacy, Adulterated Drug Products.
From the letter: “The (b)(4) curtain separating the ISO5-classified area from the surrounding ISO7-classified space is not adequately sealed.”
FDA published a close-out letter on May 28, 2026. The findings below are from the original warning letter.
At a glance
What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.
- Violations
- 15 findings · 3 issue types
- Cited
- No CFR or ISO section
- Response due
- Fifteen (15) working days of receipt
- FDA asks for
- 3 actions
- Named as possible actions
- Seizure, injunction
- Issued by
- Office of Pharmaceutical Quality Operations, Division II · Office of Inspections and Investigations
- Published status
- Close-out May 28, 2026
AI assisted findings
Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.
01Facilities & equipmentThe ISO5 area is not adequately sealed from the surrounding ISO7 space due to an unsealed curtain.
The (b)(4) curtain separating the ISO5-classified area from the surrounding ISO7-classified space is not adequately sealed.
02Facilities & equipmentA visible crack in the barrier between the ISO7 cleanroom and ISO8 space allows air influx.
There is a visible crack in the (b)(4) separating the ISO7-classified cleanroom from the adjoining ISO8-classified space.
03Production & process controlsHazardous drug products are produced in the same cleanroom as non-hazardous products without adequate containment.
hazardous drug products are produced in an ISO5-classified biological safety cabinet (BSC), which is located in the same ISO7-classified cleanroom where non-hazardous drug products are produced.
04Facilities & equipmentAn unknown foreign substance was found on a HEPA filter grille in the ISO5 area.
an unknown foreign substance was observed adhered to the plastic grille of a HEPA filter in your ISO5-classified area.
05Production & process controlsMaterials were not disinfected during transfer from ISO7 to ISO5 areas.
Your firm did not disinfect materials during transfer from the ISO7-classified cleanroom into the ISO5-classified area.
06Facilities & equipmentSmoke studies were never performed in the ISO5 BSC to demonstrate unidirectional airflow.
smoke studies have never been performed in your ISO5-classified BSC.
07Sterility & aseptic processingMedia fills were not performed under the most challenging conditions, lacking assurance of aseptic capability.
Your media fills were not performed under the most challenging or stressful conditions. Therefore, there is a lack of assurance that your firm can aseptically produce drug products within your facility.
08Facilities & equipmentResponse to sealing the curtain lacked detail on method, materials, recertification, and timeline.
you did not describe in any detail the manner in which the (b)(4) curtain will be sealed to the ceiling, or the materials to be used. Furthermore, it is likely that a modification to the ISO5 classified area would necessitate recertification of the ISO5 area, and possibly the surrounding ISO7-classified cleanroom. Your response makes no reference to recertification. Lastly, your response does not provide any time frame by which the modification will be completed, or whether production of sterile drug products will be suspended until such modification is complete.
09Facilities & equipmentResponse to the crack lacked specifics on repair method, recertification, and material suitability.
you fail to specify exactly how the repair will be made, and how the suitability of the ISO7 cleanroom and ISO5 area contained within will be assured following the repair. For example, it is likely the ISO7 area, and possibly the ISO5 area within will require recertification following the modification. Your response makes no mention of any such requirement. Furthermore, if you choose to seal the crack instead of replacing the (b)(4), you must ensure the suitability of the material used to seal the crack, as well as verify the effectiveness of such repair.
10Production & process controlsResponse to hazardous drug cross-contamination lacked immediate cessation and timeline for relocation.
it fails to address the existing cross-contamination risk as you do not commit to immediately ceasing all hazardous drug production, and you did not provide a time frame by which the relocation of the BSC will be complete. It should be noted that when moved, the BSC and room in which it will be housed, as well as the ISO7 area from which it is removed will need to be qualified and appropriately certified/re-certified prior to operation.
11Facilities & equipmentResponse to the unknown substance failed to identify its source or evaluate HEPA filter integrity.
you failed to determine the identity or source of the substance. Consequently, there’s no assurance the underlying problem has been effectively eliminated. Additionally, you did not describe if/how the HEPA filter was evaluated to ensure it was not adversely impacted by the substance (e.g., no filter integrity/leak testing, and airflow/velocity testing were conducted). Consequently, it is not known whether the environment is suitable for sterile drug production.
12Production & process controlsResponse to disinfection failure lacked specific cleaning steps and disposition of affected product.
you did not provide any specific details on the cleaning steps in which staff will be trained. Consequently, there is no assurance the outer packaging of materials and supplies will be adequately and routinely disinfected upon transfer from areas of lower air quality to areas of higher air quality. Lastly, your response does not describe the disposition of the lot of drug product being prepared when the observation was made.
13Facilities & equipmentResponse to smoke study failure lacked detail on method, evaluation, timeline, and production suspension.
you do not describe in any detail the manner in which smoke studies will be performed, or how they will be evaluated to determine the adequacy of HEPA-filtered airflow within the BSC. You do not state when the studies will be performed or a time frame by which the results will be evaluated. Additionally, your response does not commit to suspending the production of hazardous sterile drugs until the BSC can be adequately certified, to include the completion of acceptable airflow visualization (“smoke”) studies.
14Facilities & equipmentBSC was not included in certification reports, so its ISO5 classification cannot be verified.
your Sterile Compounding Suite Certification Reports from January 2021 and July 2021 do not include any reference to the BSC. Consequently, the BSC does not appear to be subject to any routine certification/re-certification requirements such as non-viable particle counts, HEPA filter leak & integrity tests, or viable air and surface sampling. Consequently, the ISO5 classification of your BSC cannot be verified, nor can its suitability to produce hazardous drug products intended to be sterile.
15Sterility & aseptic processingResponse to media fill failure lacked detail on simulating worst-case conditions and addressing other activities.
your response does not describe in any detail the specific manner in which media fill studies will be performed to ensure they simulate the most challenging, stressful conditions associated with actual drug production activities. While your response suggests steps are being taken to address variables such as batch size, it fails to address other production activities that may represent most challenging, stressful, or worst-case scenarios such as sterile (b)(4), filling, and stoppering & capping of vials, etc.
Additional FDA passages
1 extracted findingsSelected FDA passages, not the complete letter.
Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO5 area. Specifically, smoke studies have never been performed in your ISO5-classified BSC.
What FDA requested
- Provide specific steps taken to address violations, including explanation of each step to prevent recurrence and copies of related documentation.
- If products are not in violation, provide reasoning and supporting information.
- If cannot completely address within 15 working days, state reason for delay and time frame for completion.
FDA Warning Letter
41 paragraphs · 6 sectionsText as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)
Case #: 639220
1Introduction
2 paragraphs
From October 18, 2021, to November 2, 2021, a U.S. Food and Drug Administration (FDA) investigator inspected your facility, Vita Pharmacy, LLC dba Talon Pharmacy of Boerne, located at 1430 South Main Street, Suite 105, Boerne, Texas 78006. During the inspection, the investigator noted serious deficiencies in your practices for producing drug products intended or expected to be sterile, which put patients at risk.
FDA issued a Form FDA 483 to your firm on November 2, 2021. FDA acknowledges receipt of your facility’s response, dated November 15, 2021. Based on this inspection, it appears that you produced drug products that violate the Federal Food, Drug, and Cosmetic Act (FDCA).
2A. Compounded Drug Products Under the FDCA
1 paragraph
Section 503A of the FDCA describes the conditions under which human drug products compounded by a licensed pharmacist in a State licensed pharmacy or a Federal facility, or a licensed physician, qualify for exemptions from three sections of the FDCA: compliance with current good manufacturing practice (CGMP) (section 501(a)(2)(B)); labeling with adequate directions for use (section 502(f)(1)); and FDA approval prior to marketing (section 505) [21 U.S.C. §§ 351(a)(2)(B), 352(f)(1) and 355(a)].
3B. Violations of the FDCA
0 paragraphs
4Adulterated Drug Products
8 paragraphs
The FDA investigator noted that drug products intended or expected to be sterile were prepared, packed, or held under insanitary conditions, whereby they may have become contaminated with filth or rendered injurious to health, causing your drug products to be adulterated under section 501(a)(2)(A) of the FDCA. For example,
1. Your facility is designed and operated in a way that may permit the influx of lesser quality air into a higher quality air area, in that: a. The (b)(4) curtain separating the ISO5-classified area from the surrounding ISO7-classified space is not adequately sealed. b. There is a visible crack in the (b)(4) separating the ISO7-classified cleanroom from the adjoining ISO8-classified space.
2. You handled hazardous drug products without providing adequate containment and segregation to prevent cross-contamination in that hazardous drug products are produced in an ISO5-classified biological safety cabinet (BSC), which is located in the same ISO7-classified cleanroom where non-hazardous drug products are produced.
3. The ISO-classified areas had visibly dirty equipment and difficult to clean surfaces. Specifically, an unknown foreign substance was observed adhered to the plastic grille of a HEPA filter in your ISO5-classified area.
4. Your firm did not disinfect materials during transfer from the ISO7-classified cleanroom into the ISO5-classified area.
5. Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO5 area. Specifically, smoke studies have never been performed in your ISO5-classified BSC.
6. Your media fills were not performed under the most challenging or stressful conditions. Therefore, there is a lack of assurance that your firm can aseptically produce drug products within your facility.
It is a prohibited act under section 301(k) of the FDCA [21 U.S.C. § 331(k)] to do any act with respect to a drug if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being adulterated.
5C. Corrective Actions
12 paragraphs
We have reviewed your firm’s response to the Form FDA 483. Although one of your proposed corrective actions appears adequate, others are deficient. For example,
1. Facility design/airflow concerns: a. Regarding the visible gap between the (b)(4) curtain and the ceiling of your ISO7-classified cleanroom, your response notes your commitment to properly sealing the (b)(4) to the ceiling to prevent the influx of lower quality air into the ISO5-classified area. However, you did not describe in any detail the manner in which the (b)(4) curtain will be sealed to the ceiling, or the materials to be used. Furthermore, it is likely that a modification to the ISO5 classified area would necessitate recertification of the ISO5 area, and possibly the surrounding ISO7-classified cleanroom.
Your response makes no reference to recertification. Lastly, your response does not provide any time frame by which the modification will be completed, or whether production of sterile drug products will be suspended until such modification is complete.
b. Regarding the crack in the (b)(4) separating the ISO7-classified cleanroom from ISO8-classified space, your response describes a plan to either replace the (b)(4) wall or seal the crack. However, you fail to specify exactly how the repair will be made, and how the suitability of the ISO7 cleanroom and ISO5 area contained within will be assured following the repair. For example, it is likely the ISO7 area, and possibly the ISO5 area within will require recertification following the modification. Your response makes no mention of any such requirement. Furthermore, if you choose to seal the crack instead of replacing the (b)(4), you must ensure the suitability of the material used to seal the crack, as well as verify the effectiveness of such repair.
2. Regarding your response to producing hazardous drug products without adequate controls to prevent cross-contamination, you state you will relocate the BSC to a separate, negatively pressured cleanroom. While moving the BSC to a dedicated, negatively pressured cleanroom may be an effective long-term solution, it fails to address the existing cross-contamination risk as you do not commit to immediately ceasing all hazardous drug production, and you did not provide a time frame by which the relocation of the BSC will be complete. It should be noted that when moved, the BSC and room in which it will be housed, as well as the ISO7 area from which it is removed will need to be qualified and appropriately certified/re-certified prior to operation.
3. Regarding your response to the presence of an unknown substance on the plastic grille of a HEPA filter in the ISO5-classified area, you note the “dark residue” was cleaned and the “stain” removed. You also state the substance was cultured, and no growth was recovered. However, you failed to determine the identity or source of the substance. Consequently, there’s no assurance the underlying problem has been effectively eliminated. Additionally, you did not describe if/how the HEPA filter was evaluated to ensure it was not adversely impacted by the substance (e.g., no filter integrity/leak testing, and airflow/velocity testing were conducted). Consequently, it is not known whether the environment is suitable for sterile drug production.
4. Regarding your response to the failure of personnel to adequately disinfect materials as they are transferred from the ISO7-classified area to the ISO5-classified area, you state staff will be retrained in proper sterile compounding procedures, adding this training will be documented accordingly. However, you did not provide any specific details on the cleaning steps in which staff will be trained. Consequently, there is no assurance the outer packaging of materials and supplies will be adequately and routinely disinfected upon transfer from areas of lower air quality to areas of higher air quality. Lastly, your response does not describe the disposition of the lot of drug product being prepared when the observation was made.
5. Regarding the failure to perform airflow visualization (“smoke”) studies in the ISO5-classified BSC where hazardous drugs, intended to be sterile, are produced, you indicate smoke studies will be performed. However, you do not describe in any detail the manner in which smoke studies will be performed, or how they will be evaluated to determine the adequacy of HEPA-filtered airflow within the BSC. You do not state when the studies will be performed or a time frame by which the results will be evaluated. Additionally, your response does not commit to suspending the production of hazardous sterile drugs until the BSC can be adequately certified, to include the completion of acceptable airflow visualization (“smoke”) studies.
Furthermore, it is noted that your Sterile Compounding Suite Certification Reports from January 2021 and July 2021 do not include any reference to the BSC. Consequently, the BSC does not appear to be subject to any routine certification/re-certification requirements such as non-viable particle counts, HEPA filter leak & integrity tests, or viable air and surface sampling. Consequently, the ISO5 classification of your BSC cannot be verified, nor can its suitability to produce hazardous drug products intended to be sterile.
6. Regarding the failure to conduct aseptic process simulation (“media fills”) under the most challenging, stressful conditions, your response indicates you will perform media fills that more closely correlate with the (b)(4) batch sizes. However, your response does not describe in any detail the specific manner in which media fill studies will be performed to ensure they simulate the most challenging, stressful conditions associated with actual drug production activities. While your response suggests steps are being taken to address variables such as batch size, it fails to address other production activities that may represent most challenging, stressful, or worst-case scenarios such as sterile (b)(4), filling, and stoppering & capping of vials, etc.
Please be aware that section 501(a)(2)(A) of the FDCA concerning insanitary conditions applies regardless of whether drug products you compound meet the conditions of section 503A.
FDA strongly recommends that your management undertake a comprehensive assessment of operations, including facility design, procedures, personnel, processes, maintenance, materials, and systems. In particular, this review should assess your aseptic processing operations. A third-party consultant with relevant sterile drug manufacturing expertise should assist you in conducting this comprehensive evaluation.
6D. Conclusion
6 paragraphs
The violations cited in this letter are not intended to be an all-inclusive statement of violations at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations.
You should take prompt action to address any violations. Failure to adequately address any violations may result in legal action without further notice, including, without limitation, seizure and injunction.
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps that you have taken to address any violations. Please include an explanation of each step being taken to prevent the recurrence of violations, as well as copies of related documentation. This letter notifies you of our concerns and provides you an opportunity to address them. If you believe your products are not in violation of the FDCA, include your reasoning and any supporting information for our consideration. If you cannot completely address this matter within fifteen (15) working days, state the reason for the delay and the time in which you will do so.
Your written notification should refer to case number 639220.
Please electronically submit your reply, on company letterhead, to Shawn Larson, Compliance Officer, at ORAPHARM2_RESPONSES@fda.hhs.gov and Shawn.Larson@fda.hhs.gov
If you have questions regarding the contents of this letter, you may contact Dr. Larson via phone at 214-253-5216 or email at Shawn.Larson@fda.hhs.gov.
Citations and trends
Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.
This letter cites no 21 CFR section or ISO 13485 clause.
Issue types
Record details
- Issuing center
- Office of Inspections and Investigations
- Issuing office
- Office of Pharmaceutical Quality Operations, Division II
- Location
- Austin, TX, United States
- Letter posted date
- Sep 13, 2022
- Letter issue date
- Aug 29, 2022
- Addressed to
- Co-Owner
- Inspection dates · model-assisted
- Oct 18, 2021 to Nov 2, 2021
- Response window
- 15 working days after receipt of this letter
Read the source clause
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps that you have taken to address any violations.
- Record length
- 1,834 words · 10 recorded redactions
- Published status
- Close-out published May 28, 2026
- Original letter
- View on FDA.gov (opens in a new tab)
- Dataset last checked
- Nov 11, 2026 · How this is built
A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.