Thrive Health and Wellness, LLC dba Thrive Health Solutions
FDA issued a warning letter to Thrive Health and Wellness, LLC dba Thrive Health Solutions (Englewood, CO, United States) on Feb 9, 2026, citing 21 CFR 201.115. Subject: Compounding Pharmacy, Adulterated Drug Products.
From the letter: “Your personnel were observed conducting aseptic operations outside of a certified ISO 5 area.”
FDA published a close-out letter on Aug 6, 2026. The findings below are from the original warning letter.
At a glance
What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.
- Violations
- 6 findings · 4 issue types
- Cited
- 21 CFR 201.115
- Response due
- Fifteen (15) working days of receipt
- FDA asks for
- 4 actions
- Named as possible actions
- Seizure, injunction
- Issued by
- Center for Drug Evaluation and Research
- Published status
- Close-out Aug 6, 2026
AI assisted findings
Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.
01Production & process controlsAseptic operations were conducted outside a certified ISO 5 area, on a benchtop in an unclassified room shared with a blood sample centrifuge.
Your personnel were observed conducting aseptic operations outside of a certified ISO 5 area. More specifically, your personnel filled sterile drug products into syringes on a benchtop table located in an unclassified room that shared the workspace with a blood sample centrifuge.
02Sterility & aseptic processingPersonnel performing sterile operations never performed media fills, lacking assurance of aseptic production capability.
Your personnel performing sterile operations have never performed media fills. Therefore, there is a lack of assurance that your firm can aseptically produce drug products within your facility.
03Facilities & equipmentAseptic processing and surrounding areas had difficult to clean equipment and surfaces, including carpet flooring throughout the facility.
Your aseptic processing and surrounding areas had difficult to clean equipment and surfaces. For example, your entire facility flooring was covered with carpet.
04Sterility & aseptic processingPersonnel engaged in aseptic processing while wearing non-sterile gloves and with exposed hair and skin.
Your personnel engaged in aseptic processing while wearing non-sterile gloves and with exposed hair and skin.
05Sterility & aseptic processingFirm failed to use a sporicidal agent in disinfection program and used non-sterile wipes to clean the aseptic processing area.
Your firm failed to use a sporicidal agent as part of your disinfection program for the aseptic processing area and used non-sterile wipes to clean within the area where drug products were filled into syringes.
06Labeling, claims & marketingDrug products are misbranded because labeling fails to bear adequate directions for use for conditions not amenable to self-diagnosis.
The drug products you repackage, such as NAD+ 50 mg/mL and MEGALean (Tirzepatide/Cyanocobalamin) Injections 10mg/20mg/mL, are intended for conditions not amenable to self-diagnosis and treatment by individuals who are not medical practitioners; therefore, adequate directions for use cannot be written so that a layman can use these products safely for their intended uses. Consequently, their labeling fails to bear adequate directions for their intended uses.
What FDA requested
- Notify FDA in writing of specific steps taken to address any violations, or inform that you do not intend to resume production of sterile drug products not intended for immediate use.
- If you intend to resume production, include an explanation of each step being taken to prevent recurrence of any violations, as well as copies of related documentation.
- If you believe your products are not in violation, include your reasoning and any supporting information for consideration.
- Notify FDA fifteen working days prior to resuming production of any drugs intended or expected to be sterile.
FDA Warning Letter
34 paragraphs · 8 sectionsText as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)
1Introduction
2 paragraphs
From March 25, 2025, to April 3, 2025, a U.S. Food and Drug Administration (FDA) investigator inspected your facility, Thrive Health and Wellness, LLC dba Thrive Health Solutions, located at 88 Inverness Circle E Ste A-204, Englewood, CO 80112. During the inspection, the investigator noted serious deficiencies in your practices for producing drug products intended or expected to be sterile, which put patients at risk.
FDA issued a Form FDA 483 to your firm on April 3, 2025. FDA acknowledges receipt of your facility’s response, dated April 22, 2025. FDA further acknowledges that as of April 21, 2025, your firm ceased repackaging of sterile drug products not intended for immediate use. FDA also acknowledges that on May 21, 2025, your firm initiated a voluntary recall of all repackaged sterile drug products dispensed between January 2, 2025, to April 18, 2025, due to a lack of sterility assurance. Based on this inspection, it appears that you produced drug products that violate the Federal Food, Drug, and Cosmetic Act (FDCA).
2A. Compounded Drug Products Under the FDCA
1 paragraph
Section 503A of the FDCA describes the conditions under which human drug products compounded by a licensed pharmacist in a State licensed pharmacy or a Federal facility, or a licensed physician, qualify for exemptions from three sections of the FDCA: compliance with current good manufacturing practice (CGMP) (section 501(a)(2)(B)); labeling with adequate directions for use (section 502(f)(1)); and FDA approval prior to marketing (section 505) [21 U.S.C. §§ 351(a)(2)(B), 352(f)(1) and 355(a)].1
3B. Violations of the FDCA
0 paragraphs
4Adulterated Drug Products
7 paragraphs
The FDA investigator noted that drug products intended or expected to be sterile were prepared, packed, or held under insanitary conditions, whereby they may have become contaminated with filth or rendered injurious to health, causing your drug products to be adulterated under section 501(a)(2)(A) of the FDCA. For example, the investigator observed that:
1. Your personnel were observed conducting aseptic operations outside of a certified ISO 5 area. More specifically, your personnel filled sterile drug products into syringes on a benchtop table located in an unclassified room that shared the workspace with a blood sample centrifuge. These drug products were not intended for immediate administration to patients but were distributed for future administration outside your facility.
2. Your personnel performing sterile operations have never performed media fills. Therefore, there is a lack of assurance that your firm can aseptically produce drug products within your facility.
3. Your aseptic processing and surrounding areas had difficult to clean equipment and surfaces. For example, your entire facility flooring was covered with carpet.
4. Your personnel engaged in aseptic processing while wearing non-sterile gloves and with exposed hair and skin.
5. Your firm failed to use a sporicidal agent as part of your disinfection program for the aseptic processing area and used non-sterile wipes to clean within the area where drug products were filled into syringes.
Under section 301(a) of the FDCA [21 U.S.C. § 331(a)], the introduction or delivery for introduction into interstate commerce of any drug that is adulterated is a prohibited act. Further, it is a prohibited act under section 301(k) of the FDCA [21 U.S.C. § 331(k)] to do any act with respect to a drug, if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being adulterated.
5Unapproved New Drug Products
1 paragraph
You do not have any FDA-approved applications on file for the drug products that you repackage, such as NAD+ 50 mg/mL and MEGALean (Tirzepatide/Cyanocobalamin) Injections 10mg/20mg/mL.2 These products are unapproved new drugs under sections 505(a) and 301(d) of the FDCA [21 U.S.C. § 331(d)]. A new drug may not be introduced into or delivered for introduction into interstate commerce unless an application approved by FDA under section 505of the FDCA is in effect for the drug. Marketing of these products, or other applicable products, without an approved application is prohibited under section 301(d) of the FDCA [21 U.S.C. § 331(d)].3
6Misbranded Drug Products
1 paragraph
The drug products you repackage, such as NAD+ 50 mg/mL and MEGALean (Tirzepatide/Cyanocobalamin) Injections 10mg/20mg/mL, are intended for conditions not amenable to self-diagnosis and treatment by individuals who are not medical practitioners; therefore, adequate directions for use cannot be written so that a layman can use these products safely for their intended uses. Consequently, their labeling fails to bear adequate directions for their intended uses.4 Accordingly, these drug products are misbranded under section 502(f)(1) of the FDCA. The introduction or delivery for introduction of misbranded drugs into interstate commerce is prohibited under section 301(a) of the FDCA. It is also a prohibited act under section 301(k) of the FDCA to do any act with respect to a drug, if such act is done while the drug is held for sale after shipment in interstate commerce and results in the drug being misbranded.
7C. Corrective Actions
1 paragraph
We have reviewed your facility’s response to the Form FDA 483. We acknowledge that as of April 21, 2025, your firm ceased repackaging of sterile drug products not intended for immediate use. We also acknowledge that on May 21, 2025, your firm initiated a voluntary recall of all repackaged sterile drug products dispensed between January 2, 2025, to April 18, 2025, due to a lack of sterility assurance.
8D. Conclusion
4 paragraphs
The violations cited in this letter are not intended to be an all-inclusive statement of violations at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations.
If you decide to resume operations to produce sterile drug products not intended for immediate use, you should take prompt action to address any violations. Failure to adequately address any violations may result in legal action without further notice, including, without limitation, seizure and injunction.
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps you have taken to address any violations, or you may inform us that you do not intend to resume production of sterile drug products not intended for immediate use. If you intend to resume production of sterile drug products not intended for immediate use in the future, please include an explanation of each step being taken to prevent the recurrence of any violations, as well as copies of related documentation. This letter notifies you of our concerns and provides you an opportunity to address them. If you believe your products are not in violation of the FDCA, include your reasoning and any supporting information for our consideration. In addition to taking appropriate corrective actions, you should notify this office fifteen (15) working days prior to resuming production of any drugs intended or expected to be sterile in the future.
Your response and any questions regarding the contents of this letter should be sent to compoundinginspections@fda.hhs.gov. In your response, refer to the Warning Letter Number above (# 714891) and include a subject line that clearly identifies the submission as a Response to Warning Letter.
Citations and trends
Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.
Regulations
Issue types
Record details
- Issuing center
- Center for Drug Evaluation and Research
- Issuing office
- Center for Drug Evaluation and Research
- Location
- Englewood, CO, United States
- Letter posted date
- Apr 21, 2026
- Letter issue date
- Feb 9, 2026
- Addressed to
- Owner
- Inspection dates · model-assisted
- Mar 25, 2025 to Apr 3, 2025
- Response window
- 15 working days after receipt of this letter
Read the source clause
Within fifteen (15) working days of receipt of this letter, please notify this office in writing of the specific steps you have taken to address any violations, or you may inform us that you do not intend to resume production of sterile drug products not intended for immediate use.
- Record length
- 1,524 words · 0 recorded redactions
- Published status
- Close-out published Aug 6, 2026
- Original letter
- View on FDA.gov (opens in a new tab)
- Dataset last checked
- Nov 11, 2026 · How this is built
A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.