Shantou Kangjie Daily Chemical Industry Co., Ltd

FDA issued a warning letter to Shantou Kangjie Daily Chemical Industry Co., Ltd (Shantou Shi, Guangdong Sheng, China) on Jan 28, 2025, citing 21 CFR 211.84 and 21 CFR 211.22. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).”

Shantou Shi, Guangdong Sheng, ChinaIssued Jan 28, 2025Posted Feb 4, 2025No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
2 findings · 2 issue types
Response due
Not stated in the letter
FDA asks for
6 actions
Named as possible actions
Import alert, refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Components & suppliers · 21 CFR 211.84(d)(1)The firm did not test incoming raw materials, including ethanol, for identity or methanol contamination.
Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).
02Quality unit & oversight · 21 CFR 211.22(a)The firm lacked a quality unit to oversee and approve drug manufacturing operations.
Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

What FDA requested

  • Review material system and qualify all suppliers, assign retest dates.
  • Provide chemical and microbiological specifications for incoming component testing.
  • Describe component testing for identity, strength, quality, purity, including COA validation.
  • Summarize component test results and COA reliability validation SOP.
  • Summarize program for qualifying and overseeing contract testing facilities.
  • Provide assessment and remediation plan for quality unit authority and resources.

FDA Warning Letter

36 paragraphs · 4 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedJanuary 28, 2025
AddressedDear Fang Yongliang

1Introduction

4 paragraphs

Your facility is registered with the United States Food and Drug Administration (FDA) as a manufacturer of over-the-counter (OTC) drug products. FDA has reviewed the records you submitted in response to our March 25, 2024, request for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Shantou Kangjie Daily Chemical Industry Co., Ltd, FEI: 3016825286, at Kangjie Company, Xiangang Road; Simapu Town, Shantou, Guangdong, China.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your response to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) (21 U.S.C. 351(a)(2)(B)).

Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:

21. Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).

16 paragraphs

You manufacture OTC drug products including hand sanitizer. Based on the records and information you provided, you have not demonstrated that you are testing incoming raw materials used to manufacture your drug products to determine their identity.

In response to our request, you stated that you do not perform identity testing on each shipment of each lot of drug ingredients (components) before they are released for use in manufacturing.

Without adequate testing, you do not have scientific evidence that components conform to appropriate specifications prior to use in the manufacture of your drug products. As a manufacturer, you have a responsibility to sample, test, and examine drug components before use in production to assure adequate quality.

Ethanol

You manufacture drugs that contain ethanol. Your response to our records and other information indicate that you do not test your incoming ethanol, used as an active ingredient, for methanol. The use of ethanol contaminated with methanol has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Policy for Testing of Alcohol (Ethanol) and Isopropyl Alcohol for Methanol at: https://www.fda.gov/media/173005/download.

In response to this letter, provide the following:

A comprehensive review of your material system to determine whether all suppliers of components, containers, and closures, are each qualified and the materials are assigned appropriate expiration or retest dates. The review should also determine whether incoming material controls are adequate to prevent use of unsuitable components, containers, and closures.

The chemical and microbiological quality control specifications you use to test and release each incoming lot of components for use in manufacturing.

A description of how you will test each component lot for conformity with all appropriate specifications for identity, strength, quality, and purity. If you intend to accept any results from your supplier’s certificates of analysis (COAs) instead of testing each component lot for strength, quality, and purity, specify how you will robustly establish the reliability of your supplier’s results through initial validation as well as periodic re-validation. In addition, include a commitment to always conduct at least one specific identity test for each incoming component lot.

A summary of results obtained from testing all components to evaluate the reliability of the COA from each component manufacturer. Include your SOP that describes this COA validation program.

A summary of your program for qualifying and overseeing contract facilities that test the drug products you manufacture.

2. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

The records and information you provided demonstrate that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. Specifically, in your response, you noted that you do not have a QU.

Your firm’s quality systems are inadequate. See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

In response to this letter, provide the following:

A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to:o A determination of whether procedures used by your firm are robust and appropriate.o Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices.o A complete and final review of each batch and its related information before the QU disposition decision.o Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products.

3CGMP Consultant Recommended

2 paragraphs

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

4Conclusion

6 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

FDA placed products offered for import into the United States from your firm on Import Alert 66-40 on January 23, 2025.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect to verify that you have completed corrective actions to any violations.

Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Shantou Kangjie Daily Chemical Industry Co., Ltd, at Kangjie Company, Xiangang Road; Simapu Town, Shantou, Guangdong, into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission, in that the methods and controls used in their manufacture do not appear to conform to CGMP within the meaning of section 501(a)(2)(B) of the FD&C Act, 21 U.S.C. 351(a)(2)(B).

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3016825286 and ATTN: CDR Frank Verni.

Sincerely,/S/

Francis GodwinDirectorOffice of Manufacturing QualityOffice of ComplianceCenter for Drug Evaluation and Research

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Shantou Shi, Guangdong Sheng, China
Letter posted date
Feb 4, 2025
Letter issue date
Jan 28, 2025
Addressed to
Manager
Inspection dates
Not recorded
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,272 words · 0 recorded redactions
Published status
No published close-out
FDA reference
320-25-34
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built