Drugs

Scientific Protein Laboratories, LLC

FDA issued a warning letter to Scientific Protein Laboratories, LLC (Waunakee, WI, United States) on Oct 10, 2025. Subject: CGMP, Active Pharmaceutical Ingredient (API), Adulterated.

From the letter: “Failure to ensure that equipment surfaces in contact with raw materials, intermediates and API do not alter the quality of the intermediates and API beyond the official or other established specifications.”

Waunakee, WI, United StatesIssued Oct 10, 2025Posted Nov 4, 2025No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
2 findings · 2 issue types
Cited
No CFR or ISO section
Response due
Not stated in the letter
FDA asks for
5 actions
Named as possible actions
Seizure, injunction
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Facilities & equipmentEquipment surfaces in contact with materials were not maintained to prevent alteration of product quality.
Failure to ensure that equipment surfaces in contact with raw materials, intermediates and API do not alter the quality of the intermediates and API beyond the official or other established specifications.
02Investigations & OOSThe firm failed to establish and follow written procedures for investigating critical deviations or failures of intermediates and API lots to meet specifications.
Failure to establish and follow written procedures for investigating critical deviations or the failure of intermediates and API lots to meet specifications.

Additional FDA passages

2 extracted findings

Selected FDA passages, not the complete letter.

01

You failed to conduct adequate investigations into out-of-specification (OOS) results. For example:

02

Failure to address deviations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any deviations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any deviations.

What FDA requested

  • Provide a retrospective, independent review of all batches within expiry that could have been affected by (b)(4) introduced as a result of your manufacturing process, including an evaluation of retain samples for (b)(4) and a review of consumer complaints for the last three years.
  • Provide an evaluation of your process and equipment to determine whether changes can be implemented to remove the risk of foreign material introduced to APIs because of process design and materials.
  • Provide a validation report of your (b)(4) and a study conducted to justify the presence of extraneous (b)(4) up to (b)(4) in your APIs.
  • Provide a CAPA plan to implement routine, vigilant operations management oversight of facilities and equipment, ensuring prompt detection of equipment/facilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment/facility infrastructure, and improved systems for ongoing management review.
  • Provide a comprehensive, independent assessment of your overall system for investigating deviations, discrepancies, complaints, OOS results, and failures, and a detailed action plan to remediate this system, including significant improvements in investigation competencies, scope determination, root-cause evaluation, CAPA effectiveness, quality unit oversight, and written procedures.

FDA Warning Letter

38 paragraphs · 4 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedOctober 10, 2025
AddressedDear Ms. Kwiatkowski

1Introduction

5 paragraphs

The United States Food and Drug Administration (FDA) inspected your drug manufacturing facility, Scientific Protein Laboratories, LLC, FEI 2111173, at 700 East Main Street, Waunakee, from April 21 to May 2, 2025.

This warning letter summarizes significant deviations from Current Good Manufacturing Practice (CGMP) for active pharmaceutical ingredients (APIs).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your APIs are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).

We reviewed your May 23, 2025 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.

During our inspection, our investigators observed specific deviations, including but not limited to the following:

21. Failure to ensure that equipment surfaces in contact with raw materials, intermediates and API do not alter the quality of the intermediates and API beyond the official or other established specifications.

8 paragraphs

You manufacture multiple animal-derived APIs. During the inspection, our investigators observed numerous grooves and scratches on the API contact surface of a (b)(4) table, where you perform (b)(4) and initial processing of organs such as pancreases, used in the manufacture of pancrelipase. These grooves and scratches indicate that your process generates (b)(4) and may lead to contamination of your API with particulate matter (e.g., (b)(4) or particles).

In your response, you state that you serviced the affected (b)(4) table to remove scratches, conducted an inspection of all (b)(4) tables in use to identify any additional units with similar wear or damage, and decommissioned and replaced these units. You indicated that you control for (b)(4) particles using (b)(4) that can detect (b)(4) from (b)(4) to (b)(4).

Your response is inadequate because it does not provide a preventive maintenance plan to ensure that your resurfaced (b)(4) table is suitable for manufacturing. Additionally, your response lacks an evaluation of whether the (b)(4) table is made of a material that is adequate to minimize the introduction of foreign metal particles into your APIs. Furthermore, you did not provide details about your process for (b)(4) particle removal. FDA is concerned that (b)(4) from (b)(4) to (b)(4) in size may pose a risk to patients. You failed to conduct a risk assessment of APIs within expiry that may have been contaminated with (b)(4).

In response to this letter, provide:

A retrospective, independent review of all batches within expiry that could have been affected by (b)(4) introduced as a result of your manufacturing process, including an evaluation of retain samples for (b)(4) and a review of consumer complaints for the last three years.

An evaluation of your process and equipment to determine whether changes can be implemented to remove the risk of foreign material introduced to APIs because of process design and materials.

A validation report of your (b)(4) and a study conducted to justify the presence of extraneous (b)(4) up to (b)(4) in your APIs. Your corrective action and preventive action (CAPA) plan should focus on significantly reducing the maximum size of foreign particles generated by your manufacturing process.

Your CAPA plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment/facilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment/facility infrastructure, and improved systems for ongoing management review. Your plan should also ensure that appropriate actions are taken throughout the company network.

32. Failure to establish and follow written procedures for investigating critical deviations or the failure of intermediates and API lots to meet specifications.

9 paragraphs

You failed to conduct adequate investigations into out-of-specification (OOS) results. For example:

Your investigation into (b)(4) assay failures during stability testing of (b)(4) thyroid-powder lots identified your sampling procedure as the potential root cause. You revised the procedure to require (b)(4) samples from (b)(4) locations within the API drum. You performed assay testing on new samples using this revised procedure and obtained passing results. Your investigation did not include sufficient evidence or rationale to support your purported root cause. FDA is concerned with your practice of (b)(4) sampling, which has the capability to mask individually failing testing results. Additionally, this drug is a narrow therapeutic index, where content uniformity is critical.

You investigated lipase assay failure during stability testing of (b)(4) distributed pancreatin lots, but you failed to expand your investigation to other pancreatin lots. You also failed to notify your customers about these failing stability results, according to your procedure.

Your 2023 investigation into a failure of residual (b)(4) limit, a release specification in pancreatic enzyme concentrate, identified (b)(4) in the (b)(4) as a potential root cause, affecting (b)(4) and subsequent (b)(4) specification failure. You implemented CAPA, but subsequently you had an additional residual (b)(4) limit failure in 2024. While you did not release these batches, your investigation lacked an adequate root cause analysis to assess all sources of variability in your manufacturing process that could be contributing to the failures.

FDA documented multiple batch rejections based on positive (b)(4) test results for (b)(4). We acknowledge that you rejected these batches and recognize (b)(4) is a known risk factor in animal-derived APIs. The manufacturing processes for both thyroid and pancrelipase products are inherently high-risk because traditional viral clearance methods are generally not feasible, thus requiring a control strategy of discarding any (b)(4)-positive material. Critical gaps in the investigation of positive (b)(4) results in the affected pancrelipase products included inadequate evaluation of cleaning procedures between contaminated batches, failure to extend the investigation beyond positive batches to all source material, and failure to assess whether thyroid lots and infected pancreas material were sourced from the same supplier.

In your response, you state that you revised your investigation procedure to ensure consistent and robust root-cause determination, to establish scope requirements to assess potential impact on other lots and manufacturing processes, to require CAPA determination for all critical and major investigations, and to establish explicit instructions to inform clients to place APIs on hold until the completion of the investigation.

Your response is inadequate because it does not demonstrate that you adequately identify root cause, implement effective remediations, and expand the investigation to evaluate the effect(s) on other batches or APIs. Additionally, your response fails to provide adequate details about your CAPAs and fails to provide supporting documentation for your CAPAs.

Inadequate investigations can lead to unidentified root causes, ineffective CAPAs, and recurring problems that compromise the ability to manufacture safe and effective APIs.

In response to this letter, provide a comprehensive, independent assessment of your overall system for investigating deviations, discrepancies, complaints, OOS results, and failures. Provide a detailed action plan to remediate this system. Your action plan should include but not be limited to significant improvements in investigation competencies, scope determination, root-cause evaluation, CAPA effectiveness, quality unit oversight, and written procedures. Address how your firm will ensure that all phases of investigations are appropriately conducted.

4Conclusion

6 paragraphs

The deviations cited in this letter are not intended to be an all-inclusive list of deviations that exist at your facility. You are responsible for investigating and determining the causes of any deviations and for preventing their recurrence or the occurrence of other deviations.

If you are considering an action that is likely to lead to a disruption in the supply of drugs produced at your facility, FDA requests that you contact CDER’s Drug Shortages Staff immediately, at drugshortages@fda.hhs.gov, so that FDA can work with you on the most effective way to bring your operations into compliance with the law. Contacting the Drug Shortages Staff also allows you to meet any obligations you may have to report discontinuances or interruptions in your drug manufacture under 21 U.S.C. 356C(b). This also allows FDA to consider, as soon as possible, what actions, if any, may be needed to avoid shortages and protect the health of patients who depend on your products.

Correct any deviations promptly. Failure to promptly and adequately address this matter may result in regulatory or legal action without further notice, including, without limitation, seizure and injunction. Unresolved deviations may also prevent other Federal agencies from awarding contracts.

Failure to address deviations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any deviations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any deviations.

This letter notifies you of our findings and provides you with an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days.1 Specify what you have done to address any deviations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and provide your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 2111173 and ATTN: Rokhsana Safaai-Jazi.

Sincerely,/S/

Francis GodwinDirectorOffice of Manufacturing QualityOffice of ComplianceCenter for Drug Evaluation and Research

_________________

1 Under program enhancements for the Generic Drug User Fee Amendments (GDUFA) reauthorization for fiscal years (FYs) 2023-2027, also known as the GDUFA III Commitment Letter, your facility may be eligible for a Post-Warning Letter Meeting to obtain preliminary feedback from FDA on the adequacy and completeness of your corrective action plans.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

This letter cites no 21 CFR section or ISO 13485 clause.

Issue types

Investigations & OOSAI-assigned issue type199letters1finding here
46 letters issued this year vs 33 by the same date last year · +39%

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Waunakee, WI, United States
Letter posted date
Nov 4, 2025
Letter issue date
Oct 10, 2025
Addressed to
Regulatory Affairs Manager
Inspection dates
Apr 21, 2025 to May 2, 2025
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,584 words · 40 recorded redactions
Published status
No published close-out
FDA reference
320-26-02
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.