FDA warning letter · Drugs

New England Life Care, Inc. dba Advanced Compounding Solutions

Issued · Posted by FDA

Selected passages from the FDA letter

Quoted FDA text from the published dataset. These selected excerpts are not the complete letter.

Passage 1

Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area. Therefore, your products intended to be sterile are produced in an environment that may not provide adequate protection against the risk of contamination.

Passage 2

Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed (21 CFR 211.192).

Passage 3

Your firm failed to establish and follow adequate written procedures describing the handling of all written and oral complaints regarding a drug product, including provisions for review by the quality control unit of any complaint involving the possible failure of a drug product to meet any of its specifications and, for such drug products, a determination as to the need for an investigation in accordance with 21 CFR 211.192 (21 CFR 211.198(a)).

Passage 4

Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes (21 CFR 211.113(b)).

Passage 5

Your firm failed to establish an adequate system for cleaning and disinfecting the room and equipment to produce aseptic conditions (21 CFR 211.42(c)(10)(v)).

Passage 6

Your firm failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair (21 CFR 211.58).

Passage 7

Your firm failed to establish an adequate air supply filtered through high-efficiency particulate air filters under positive pressure in the aseptic processing areas (21 CFR 211.42(c)(10)(iii)).

Citations in the original letter

As cited in this historical letter, not a statement of current regulatory requirements.

  • 21 CFR 200.10(b)
  • 21 CFR 201.115
  • 21 CFR 210
  • 21 CFR 210.1(b)
  • 21 CFR 211.192
  • 21 CFR 211.198(a)
  • 21 CFR 211.113(b)
  • 21 CFR 211.42(c)(10)(v)
  • 21 CFR 211.58
  • 21 CFR 211.42(c)(10)(iii)