Madhu Instruments Private Limited

FDA issued a warning letter to Madhu Instruments Private Limited (New Delhi, India) on Feb 1, 2024. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “Peeling paint on the ceilings of your firm’s ISO 7 manufacturing rooms.”

New Delhi, IndiaIssued Feb 1, 2024Posted Feb 13, 2024No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
8 findings · 2 issue types
Cited
No CFR or ISO section
Response due
Not stated in the letter
FDA asks for
3 actions
Named as possible actions
Import alert, detention, refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Facilities & equipmentPeeling paint on ceilings of ISO 7 rooms created contamination risks.
Peeling paint on the ceilings of your firm’s ISO 7 manufacturing rooms.
02Facilities & equipmentA plastic bag covering a HEPA filter impeded airflow in the manufacturing area.
A plastic bag covering the high efficiency particulate air (HEPA) filter in the manufacturing area impeding adequate airflow.
03Facilities & equipmentBroken tiles with residue along walls in manufacturing rooms posed contamination risks.
Broken tiles along the base of the wall in the manufacturing rooms that were observed to have an (b)(4) residue adhering to them. (b)(4) is (b)(4) in color.
04Facilities & equipmentHoles patched with (b)(4) and masking tape used to secure items to walls.
A (b)(4) was used to patch holes in the walls, and masking tape was used to secure (b)(4) and (b)(4) to walls of the manufacturing rooms.
05Facilities & equipmentManufacturing equipment was visibly dirty and stained with oil or grease.
During the FDA inspection, your manufacturing equipment, including (b)(4) machines were found to be visibly dirty and appeared to be stained with oil or grease residues.
06Facilities & equipmentCardboard box lined with stained masking tape used to catch product.
The cardboard box used to catch the product (b)(4) after (b)(4) is lined with white masking tape that has become stained and soiled over time.
07Facilities & equipmentPrinter paper taped to work surface used for filling and packaging.
Additionally, the manual operation uses printer paper taped to the work surface on which filling and packaging of the products are performed.
08Production & process controlsInadequate controls to maintain a suitable production environment and prevent contamination.
You do not have adequate controls in place to maintain a suitable production environment and prevent contamination of products manufactured at your facility.

Additional FDA passages

1 extracted findings

Selected FDA passages, not the complete letter.

01

Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Madhu Private Limited, A-260, Okhla Industrial Area, Phase-1, New Delhi, India, into the United States under section 801 of the FD&C Act, 21 U.S.C. 381. Articles under this authority that appear to be adulterated or misbranded are subject to detention or refusal of admission.

What FDA requested

  • Your plan that assesses the vulnerabilities in your equipment cleaning and disinfection processes and practices, as well as facility and equipment design, which develops appropriate remediations to prevent contamination and provides timelines for completion.
  • Your plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment/facilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment/facility infrastructure, and improved systems for ongoing management review.
  • Documentation that supports your corrective actions such as work orders, room qualification, photos of any repairs your firm has made to correct the violation, and systemic plans to ensure the manufacturing areas remain adequately designed, controlled, and maintained.

FDA Warning Letter

29 paragraphs · 3 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedFebruary 1, 2024
AddressedDear Mr. Gupta

1Introduction

3 paragraphs

The U.S. Food and Drug Administration (FDA) inspected your manufacturing facility, Madhu Instruments Private Limited FEI 3007317099, at A-260, Okhla Industrial Area, Phase-1, New Delhi, from October 11 to 21, 2022.

FDA determined that (b)(4) manufactured at your facility are adulterated within the meaning of section 501(a)(2)(A) of the Federal Food, Drug, and Cosmetic Act (the FD&C Act), 21 U.S.C. 351(a)(2)(A), in that they have been prepared, packed, or held under insanitary conditions whereby they may have been contaminated with filth, or whereby they may have been rendered injurious to health.

We reviewed your November 11, 2022, response to our Form FDA 483 in detail. Your response is inadequate because it did not provide sufficient detail or evidence of corrective actions to bring your operations into compliance with the FD&C Act.

2Insanitary Conditions

12 paragraphs

FDA investigators observed that products intended or expected to be sterile were prepared, packed, or held under insanitary conditions, whereby they may have become contaminated with filth or rendered injurious to health, causing your products to be adulterated under section 501(a)(2)(A) of the FD&C Act. During the inspection, the investigators observed your manufacturing facility of products intended or expected to be sterile was in a state of disrepair, as noted by the following examples:

Peeling paint on the ceilings of your firm’s ISO 7 manufacturing rooms.

A plastic bag covering the high efficiency particulate air (HEPA) filter in the manufacturing area impeding adequate airflow.

Broken tiles along the base of the wall in the manufacturing rooms that were observed to have an (b)(4) residue adhering to them. (b)(4) is (b)(4) in color.

A (b)(4) was used to patch holes in the walls, and masking tape was used to secure (b)(4) and (b)(4) to walls of the manufacturing rooms.

You do not have adequate controls in place to maintain a suitable production environment and prevent contamination of products manufactured at your facility. During the FDA inspection, your manufacturing equipment, including (b)(4) machines were found to be visibly dirty and appeared to be stained with oil or grease residues. The cardboard box used to catch the product (b)(4) after (b)(4) is lined with white masking tape that has become stained and soiled over time. Additionally, the manual operation uses printer paper taped to the work surface on which filling and packaging of the products are performed.

In your response, you acknowledged that your cleaning and sanitization standard operating procedure (SOP) was inadequate, and your facility preventive maintenance plan was not implemented properly. You implemented a new checklist to verify and monitor cleaning and sanitization of the manufacturing areas and revised your SOPs for cleaning.

Your response is inadequate because you failed to conduct a retrospective review and assessment of the risks to product quality, including all potential contamination risks. Previously you had committed to improving your cleaning procedures but thus far have not adequately developed a cleaning and sanitization regimen that minimizes the risk of contamination. Although you terminally sterilize your (b)(4), it is imperative that you adequately design and maintain your facility to prevent the risk of adding contaminants, such as extraneous particulates, to your product.

In response to this letter, provide the following:

Your plan that assesses the vulnerabilities in your equipment cleaning and disinfection processes and practices, as well as facility and equipment design, which develops appropriate remediations to prevent contamination and provides timelines for completion.

Your plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment/facilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment/facility infrastructure, and improved systems for ongoing management review.

Documentation that supports your corrective actions such as work orders, room qualification, photos of any repairs your firm has made to correct the violation, and systemic plans to ensure the manufacturing areas remain adequately designed, controlled, and maintained.

3Conclusion

7 paragraphs

FDA placed your firm on Import Alert 66-40 on May 31, 2023.

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

If you are considering an action that is likely to lead to a disruption in the supply of the products produced at your facility, FDA requests that you contact the Agency immediately, at drugshortages@fda.hhs.gov, so that FDA can work with you on the most effective way to bring your operations into compliance with the law. Contacting the FDA also allows you to meet any obligations you may have to report discontinuances or interruptions in your product manufacture under the FD&C Act. This also allows FDA to consider, as soon as possible, what actions, if any, may be needed to avoid shortages and protect the health of patients who depend on your products.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a manufacturer until any violations are completely addressed and we confirm your compliance with the Act. We may re-inspect to verify that you have completed corrective actions for any violations.

Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Madhu Private Limited, A-260, Okhla Industrial Area, Phase-1, New Delhi, India, into the United States under section 801 of the FD&C Act, 21 U.S.C. 381. Articles under this authority that appear to be adulterated or misbranded are subject to detention or refusal of admission.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3007317099 and ATTN: Rokhsana Safaai-Jazi

Sincerely, /S/

Francis Godwin Director Office of Manufacturing Quality Office of Compliance Center for Drug Evaluation and Research

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

This letter cites no 21 CFR section or ISO 13485 clause.

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
New Delhi, India
Letter posted date
Feb 13, 2024
Letter issue date
Feb 1, 2024
Addressed to
Director
Inspection dates
Oct 11, 2022
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,058 words · 11 recorded redactions
Published status
No published close-out
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.