Imperial Palace Commodity -Dongguan- Co., Ltd.

FDA issued a warning letter to Imperial Palace Commodity -Dongguan- Co., Ltd. (Dongguan Shi, Guangdong Sheng, China) on Jan 27, 2025, citing 21 CFR 211.84, 21 CFR 211.100, 21 CFR 211.160 and 21 CFR 211.22. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality.”

Dongguan Shi, Guangdong Sheng, ChinaIssued Jan 27, 2025Posted Feb 4, 2025No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
4 findings · 4 issue types
Response due
Not stated in the letter
FDA asks for
4 actions
Named as possible actions
Import alert, refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Components & suppliers · 21 CFR 211.84(d)(1)Failed to adequately test incoming components, including glycerin and ethanol, for identity and contamination risks (DEG/EG and methanol).
Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).
02Production & process controls · 21 CFR 211.100(a)Failed to adequately validate the manufacturing process for alcohol wipe drug products, providing only analytical test results without proper process validation.
Your firm failed to establish adequate written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).
03Laboratory controls & testing · 21 CFR 211.160(b)Failed to use appropriate microbiological test methods in stability program, using 'Antibacterial efficacy test' instead of USP <51> for products without preservatives.
Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).
04Quality unit & oversight · 21 CFR 211.22(a)Quality unit failed to exercise adequate oversight over materials and laboratory control systems.
Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

Additional FDA passages

1 extracted findings

Selected FDA passages, not the complete letter.

01

Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Imperial Palace Commodity Dongguan Co., Ltd., at No. 523 1st Liudong Road, Changlong Village, Huangjiang Town, Dongguan, Guangdong 523750, China, into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission.

What FDA requested

  • Engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements.
  • The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions.
  • Respond to this office in writing within 15 working days, specifying what you have done to address any violations and to prevent their recurrence.
  • If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

FDA Warning Letter

43 paragraphs · 4 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedJanuary 27, 2025
AddressedDear Mr. Xu

1Introduction

3 paragraphs

Your facility is registered with the United States Food and Drug Administration (FDA) as a manufacturer of over-the-counter (OTC) drug products. FDA has reviewed the records you submitted in response to our March 4, 2024 request, and subsequent requests, for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Imperial Palace Commodity (Dongguan) Co., Ltd., FEI 3014838570, at No. 523 1st Liudong Road, Changlong Village, Huangjiang Town, Dongguang, Guangdong 523750, China.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your responses to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act (21 U.S.C. 351(a)(2)(B)).

2704(a)(4) Request for Records and Related CGMP Violations

22 paragraphs

Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:

1. Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).

Your firm manufactures OTC drug products such as alcohol wipes. Based on the records and information you provided, you did not demonstrate that you have adequately tested incoming components used in the manufacture of your drug products. For example, you failed to conduct adequate identity testing on your incoming components. Additionally, your firm relied on the certificates of analysis (COAs) from your suppliers and failed to establish the reliability of each of your suppliers’ COA for component specifications and characteristics at appropriate intervals.

Glycerin

Information provided indicates that you failed to demonstrate that you adequately test each shipment of each lot of glycerin for identity, a component at higher risk for diethylene glycol (DEG) and ethylene glycol (EG) contamination. We note that glycerin is an ingredient used in your alcohol wipe drug products. Identity testing of glycerin, along with other high-risk drug components1, includes a limit test in the United States Pharmacopeia (USP) to ensure that the component meets the relevant safety limits for levels of DEG or EG. Because you did not perform identity testing on each shipment of each glycerin lot using the USP identification tests that detects these hazardous impurities, you failed to assure the acceptability of this component for use in the manufacture of your drug products.

The use of ingredients contaminated with DEG or EG has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and Other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol to help you meet the CGMP requirements when manufacturing drugs containing ingredients at high-risk for DEG or EG contamination at https://www.fda.gov/media/167974/download.

Ethanol

You also failed to adequately test your incoming component, ethanol, used as an active ingredient in your alcohol wipes, for methanol. The use of ethanol contaminated with methanol has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Policy for Testing of Alcohol (Ethanol) and Isopropyl Alcohol for Methanol to help you meet the CGMP requirements when manufacturing drugs containing ethanol at https://www.fda.gov/media/173005/download.

Without adequate testing, you do not have scientific evidence that your incoming components conform to appropriate specifications before use in the manufacture of your drug products.

2. Your firm failed to establish adequate written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).

Process Validation

Based on the records and information you provided, you did not demonstrate that you have adequately validated the manufacturing process for your alcohol wipe drug products. For example, the records you provided to demonstrate your process validation for your drug products, included only reports of analytical test results.

Process validation evaluates the soundness of design and state of control of a process throughout its lifecycle. Each significant stage of a manufacturing process must be designed appropriately and assure the quality of raw material inputs, in-process materials, and finished drugs. Process qualification studies include intensive monitoring and testing throughout each significant process stage to characterize intra-batch variation and evaluate batches to determine whether an initial state of control has been established. Successful process qualification studies are necessary before commercial distribution. Thereafter, ongoing vigilant oversight of process performance and product quality is necessary to ensure you maintain a stable manufacturing operation throughout the product lifecycle.

See FDA’s guidance document Process Validation: General Principles and Practices for general principles and approaches that FDA considers appropriate elements of process validation, at https://www.fda.gov/media/71021/download.

Water System Validation

Your firm uses water as a component in your drug products. You have not demonstrated that your firm’s water system has been adequately designed and validated for its intended use. For example, your response states that your water system is qualified only for (b)(4) water. In addition, your (b)(4) water validation report did not include testing results for total organic carbon. Your firm has not demonstrated that the water is suitable for use and meets the USP (b)(4) Water monograph specifications.

3. Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).

Based on the records and information you provided, you did not demonstrate that you used an appropriate test method for microbiological testing as part of your stability program. For example, the records you provided for your stability program identified your microbiological testing method as “Antibacterial efficacy test-refer to USP 40 51>.” You reported results for “total aerobic microbial count,” “coliform bacteria,” and “fungi,” as well as other specified microorganisms, but your results reflect that your methods are not consistent with USP <51> Antimicrobial Effectiveness Testing. The methodology described in USP <51> is intended to demonstrate the effectiveness of added microbial preservatives; however, your response states that your drug products do not contain preservatives.

Without appropriate test methods, you do not have scientific evidence to support whether your drug products meet their established microbiological specifications through their labeled expiry.

4. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

The records and information you provided demonstrated that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. For example, your QU did not adequately exercise its authority over the establishment of controls in your Materials System and Laboratory Control System.

Your QU is responsible for fully exercising its authority and responsibilities. FDA is concerned that your QU may not be conducting appropriate oversight regarding CGMP operations. See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

3CGMP Consultant Recommended

1 paragraph

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions.

4Conclusion

6 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

FDA placed products offered for import into the United States from your firm on Import Alert 66-40 on January 23, 2025.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect to verify that you have completed corrective actions to any violations.

Failure to address any violations may also result in the FDA continuing to refuse admission of articles manufactured at Imperial Palace Commodity Dongguan Co., Ltd., at No. 523 1st Liudong Road, Changlong Village, Huangjiang Town, Dongguan, Guangdong 523750, China, into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3014838570 and ATTN: Joel Hustedt.

Sincerely,/S/

Francis GodwinDirectorOffice of Manufacturing QualityOffice of ComplianceCenter for Drug Evaluation and Research

CC:Registered U.S. AgentPro Medical Supplies, Inc.Mr. Jake SztejmanEmail: Jake.Sztejman@outlook.com

_________________________

1 Components with higher risk of DEG or EG contamination compared to other drug components.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Dongguan Shi, Guangdong Sheng, China
Letter posted date
Feb 4, 2025
Letter issue date
Jan 27, 2025
Addressed to
General Manager
Inspection dates
Not recorded
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,659 words · 3 recorded redactions
Published status
No published close-out
FDA reference
320-25-33
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.