Ignacio Reyes Gonzalez
FDA issued a warning letter to Ignacio Reyes Gonzalez (Tlaquepaque, Jal., Mexico) on Jan 25, 2021, citing 21 CFR 330.1 and 21 CFR 201.128. Subject: Finished Pharmaceuticals, Unapproved New Drug, Misbranded, Adulterated.
From the letter: “MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA, declared to be manufactured at your facility, is labeled to contain 70% volume/volume (v/v) of the active ingredient ethyl alcohol (ethanol).”
At a glance
What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.
- Violations
- 11 findings · 2 issue types
- Cited
- 21 CFR 330.1, 21 CFR 201.128
- Response due
- Not stated in the letter
- FDA asks for
- 4 actions
- Named as possible actions
- Seizure, import alert, refusal of admission
- Issued by
- Center for Drug Evaluation and Research
- Published status
- No close-out recorded
AI assisted findings
Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.
01Labeling, claims & marketingHand sanitizer labeled as 70% ethanol contained 1.4% ethanol and 63% methanol, causing adulteration and substitution.
MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA, declared to be manufactured at your facility, is labeled to contain 70% volume/volume (v/v) of the active ingredient ethyl alcohol (ethanol). However, FDA laboratory testing of a batch of this product detained at the border found that the drug product contained on average 1.4% ethanol and an average of 63% methanol v/v. Therefore, this hand sanitizer drug product is adulterated under section 501(d)(2) of the FD&C Act in that the active ingredient, ethanol, was substituted wholly or in part with methanol, a dangerous chemical when in contact with human skin or ingested.
02Quality unit & oversightQuality assurance failed to prevent methanol substitution, violating CGMP requirements.
The substitution and contamination with methanol in a drug product declared as manufactured in your facility demonstrates that the quality assurance within your facility is not functioning in accordance with CGMP requirements under section 501(a)(2)(B) of the FD&C Act.
03Labeling, claims & marketingHand sanitizer is an unapproved new drug without FDA approval or GRASE status.
This hand sanitizer product is a “new drug” within the meaning of section 201(p) of the FD&C Act, 21 U.S.C. 321(p), because it is not generally recognized as safe and effective (GRASE) for use under the conditions prescribed, recommended, or suggested in its labeling. New drugs may not be introduced or delivered for introduction into interstate commerce without prior approval from FDA, as described in section 505(a) of the FD&C Act, 21 U.S.C. 355(a), unless they are lawfully marketed under section 505G of the FD&C Act (which is not the case for this product, as further described below). No FDA-approved application pursuant to section 505 of the FD&C Act, 21 U.S.C. 355, is in effect for this hand sanitizer product, nor are we aware of any adequate and well-controlled clinical studies in the published literature that support a determination that your MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA drug product is GRASE for use under the conditions suggested, recommended, or prescribed in its labeling. Accordingly, this product is an unapproved new drug marketed in violation of sections 505(a) and 301(d) of the FD&C Act, 21 U.S.C 355(a) and 331(d).
04Labeling, claims & marketingProduct does not conform to TFM or meet conditions for marketing without approval.
However, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA does not conform to the 1994 TFM, as further amended by the 2016 Consumer Antiseptic Rub proposed rule, nor any other TFM, proposed rule, or final rule, and does not meet the conditions under section 505G(a)(3) of the FD&C Act for marketing without an approved application under section 505.
05Labeling, claims & marketingProduct lacks declared ethanol, failing TFM and FDA temporary policy conformity.
According to the product label, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA purportedly contains the active ingredient ethyl alcohol (ethanol) 70% v/v. However, as previously discussed, FDA laboratory analysis revealed that a sample of MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA contained little to no ethanol. Such a product does not conform with the TFM and the applicable requirements for nonprescription drugs,*2* nor is it consistent with the formulations described in FDA’s temporary policies for hand sanitizers during the COVID-19 public health emergency.*3*
06Labeling, claims & marketingUndeclared methanol in product violates TFM and FDA temporary policy.
FDA laboratory analyses also revealed that a sample of MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA contain significant concentrations of the undeclared ingredient methyl alcohol (methanol). Use of methanol as an active ingredient is not in conformance with the TFM, nor is it included in the formulations described in FDA’s *Temporary Policy for Preparation of Certain Alcohol-Based Hand Sanitizer Products During the Public Health Emergency (COVID-19)*: Guidance for Industry.
07Labeling, claims & marketing · 21 CFR 330.1(e)Methanol as inactive ingredient is unsafe and unsuitable under 21 CFR 330.1(e).
Furthermore, methanol is not acceptable as an inactive ingredient in hand sanitizers. As previously discussed, methanol has significant and sometimes fatal toxic effects and, therefore, does not meet the requirements under 21 CFR 330.1(e) that that a product’s inactive ingredients be safe and suitable.*4*
08Labeling, claims & marketingProduct is dangerous to health due to methanol exposure, causing misbranding.
It is misbranded under section 502(j) of the FD&C Act, 21 U.S.C. 352(j), because it is dangerous to health when used according to its labeling as a hand sanitizer. As previously stated, skin exposure to methanol could lead to systemic absorption, and substantial methanol exposure can potentially result in, among other things, blindness, permanent nervous system damage, and even death.
09Labeling, claims & marketingLabeling falsely claims ethanol and omits methanol, making it misleading.
This hand sanitizer is misbranded under section 502(a) of the FD&C Act, 21 U.S.C 352(a), because its labeling is false or misleading. As noted above, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is labeled to contain ethyl alcohol 70% v/v. However, FDA laboratory analysis revealed that a sample of this product detained at the border contains little to no ethyl alcohol and a significant concentration of methyl alcohol (methanol), an ingredient that is not declared on the product label. Section 201(n) of the FD&C Act, 21 U.S.C. 321(n), provides that “in determining whether the labeling or advertising is misleading there shall be taken into account . . . not only representations made or suggested . . . but also the extent to which the labeling or advertising fails to reveal facts material in the light of such representations or material with respect to consequences which may result. . ..” Thus, the misleading representation of the concentration of the active ingredient ethyl alcohol (ethanol) and the failure of the labeling to disclose the presence of the methyl alcohol (methanol) in the product, causes this product to be misbranded under section 502(a) of the FD&C Act, 21 U.S.C. 352(a).
10Labeling, claims & marketingFailure to list methanol on label causes misbranding under section 502(e)(1)(A).
The failure of this product to list methanol as an ingredient on its label causes it to be misbranded under section 502(e)(1)(A) of the FD&C Act, 21 U.S.C. 352(e)(1)(A).
11Labeling, claims & marketingNonprescription drug fails to comply with section 505G, causing misbranding.
Lastly, this product is misbranded under section 502(ee) of the FD&C Act, 21 U.S.C. 352(ee) because MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is a nonprescription drug subject to section 505G of the FD&C Act, 21 U.S.C. 355h, but does not comply with the requirements for marketing under that section and is not the subject of an application approved under section 505 of the FD&C Act, 21 U.S.C. 355.
What FDA requested
- A detailed investigation into how the drug product described above, which was declared as manufactured at your facility and which was labeled as containing ethanol, was substituted in part or in whole with methanol.
- A list of all raw materials used to manufacture all of your hand sanitizer drug products, including the suppliers’ names, addresses, and contact information.
- A list of all batches of any hand sanitizer drug products shipped to the United States by your firm, and a full reconciliation of all material you distributed.
- Copies of the complete batch records for all batches distributed to the U.S.
FDA Warning Letter
46 paragraphs · 4 sectionsText as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)
1Introduction
3 paragraphs
Your firm was recently registered as a human drug manufacturer. The U.S. Food and Drug Administration (FDA) conducted testing of a consumer antiseptic hand rub drug product (also referred to as consumer hand sanitizer) labeled as MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA. This product was declared to be manufactured at your facility, Ignacio Reyes Gonzalez, FEI 3016931251, Calle Independencia 416, Col. Los Puestos, Tlaquepaque, Jalisco, 45560 Mexico. Following an attempt to import MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA into the United States, it was detained and refused admission at the border.
The results of FDA laboratory testing of a batch of this product detained at the border demonstrated that MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA drug product, declared to be manufactured at your facility, is adulterated within the meaning of section 501(d)(2) of the Federal Food, Drug, and Cosmetic Act (FD&C Act or the Act), 21 U.S.C. 351(d)(2), in that a substance was substituted wholly or in part therefor. In addition, this product is adulterated within the meaning of section 501(a)(2)(B) (21 U.S.C. 351(a)(2)(B)), in that the substitution demonstrates that the quality assurance within your facility is not functioning in accordance with Current Good Manufacturing Practice (CGMP) requirements.
In addition, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is an unapproved new drug introduced or delivered for introduction into interstate commerce in violation of section 505(a) of the FD&C Act, 21 U.S.C. 355(a), and is misbranded under sections 502(j), (a), (e), and (ee) of the FD&C Act, 21 U.S.C. 352(j), (a), (e), and (ee). Introduction or delivery for introduction of this product into interstate commerce is prohibited under sections 301(d) and (a) of the FD&C Act, 21 U.S.C. 331(d) and (a). These violations are described in more detail below.
2Adulteration Violations
22 paragraphs
MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA, declared to be manufactured at your facility, is labeled to contain 70% volume/volume (v/v) of the active ingredient ethyl alcohol (ethanol). However, FDA laboratory testing of a batch of this product detained at the border found that the drug product contained on average 1.4% ethanol and an average of 63% methanol v/v. Therefore, this hand sanitizer drug product is adulterated under section 501(d)(2) of the FD&C Act in that the active ingredient, ethanol, was substituted wholly or in part with methanol, a dangerous chemical when in contact with human skin or ingested.
Methanol is not an acceptable ingredient for hand sanitizers and should not be used due to its toxic effects. Skin exposure to methanol can cause dermatitis, as well as transdermal absorption with systemic toxicity. Substantial methanol exposure can result in nausea, vomiting, headache, blurred vision, permanent blindness, seizures, coma, permanent damage to the nervous system, or death. Although all persons using these products on their hands are at risk, young children who accidently ingest these products, and adolescents and adults who drink these products as an alcohol (ethanol) substitute, are most at risk for methanol poisoning.
While the contaminated drug products detailed above were shipped to the United States, information available to FDA indicates that all shipments of your hand sanitizers were detained and refused admission at the border and did not enter the United States. On August 13, 2020, FDA notified the public of the substitution of your hand sanitizer drugs products at the following website: https://www.fda.gov/drugs/drug-safety-and-availability/fda-updates-hand-sanitizers-consumers-should-not-use
In response to this letter provide:
• A detailed investigation into how the drug product described above, which was declared as manufactured at your facility and which was labeled as containing ethanol, was substituted in part or in whole with methanol.
• A list of all raw materials used to manufacture all of your hand sanitizer drug products, including the suppliers’ names, addresses, and contact information.
• A list of all batches of any hand sanitizer drug products shipped to the United States by your firm, and a full reconciliation of all material you distributed.
• Copies of the complete batch records for all batches distributed to the U.S.
The substitution and contamination with methanol in a drug product declared as manufactured in your facility demonstrates that the quality assurance within your facility is not functioning in accordance with CGMP requirements under section 501(a)(2)(B) of the FD&C Act.1 Unapproved New Drug and Misbranding Violations
MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is a “drug” as defined by section 201(g)(1)(B) of the FD&C Act, 21 U.S.C. 321(g)(1)(B), because it is intended for use in the diagnosis, cure, mitigation, treatment, or prevention of disease and/or under section 201(g)(1)(C) of the FD&C Act, 21 U.S.C. 321(g)(1)(C), because it is intended to affect the structure or any function of the body. Specifically, this product is intended as a consumer antiseptic hand rub.
Examples of claims observed on the product label that provide evidence of the intended use (as defined in 21 CFR 201.128) of the product include, but may not be limited to, the following:
“Hand Sanitizer Gel ANTIMICROBIAL FORMULA . . . Drug facts Use: Hand sanitizer to help reduce bacteria on skin.” (product label)
This hand sanitizer product is a “new drug” within the meaning of section 201(p) of the FD&C Act, 21 U.S.C. 321(p), because it is not generally recognized as safe and effective (GRASE) for use under the conditions prescribed, recommended, or suggested in its labeling. New drugs may not be introduced or delivered for introduction into interstate commerce without prior approval from FDA, as described in section 505(a) of the FD&C Act, 21 U.S.C. 355(a), unless they are lawfully marketed under section 505G of the FD&C Act (which is not the case for this product, as further described below). No FDA-approved application pursuant to section 505 of the FD&C Act, 21 U.S.C. 355, is in effect for this hand sanitizer product, nor are we aware of any adequate and well-controlled clinical studies in the published literature that support a determination that your MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA drug product is GRASE for use under the conditions suggested, recommended, or prescribed in its labeling. Accordingly, this product is an unapproved new drug marketed in violation of sections 505(a) and 301(d) of the FD&C Act, 21 U.S.C 355(a) and 331(d).
We note that over-the-counter (OTC) topical antiseptic products had been the subject of rulemaking under the Agency’s OTC Drug Review. In particular, such products were addressed in a tentative final monograph (TFM) entitled “Topical Antimicrobial Drug Products for Over-the-Counter Human Use; Tentative Final Monograph for Health-Care Antiseptic Drug Products,” Proposed Rule, 59 FR 31402 (June 17, 1994) (1994 TFM), as further amended by the “Safety and Effectiveness of Consumer Antiseptics; Topical Antimicrobial Drug Products for Over-the-Counter Human Use; Proposed Amendment of the Tentative Final Monograph; Reopening of Administrative Record,” Proposed Rule, 81 FR 42912 (June 30, 2016). Over the course of these rulemakings, three active ingredients (benzalkonium chloride, ethyl alcohol, and isopropyl alcohol) were classified as Category III for use as consumer antiseptic rub products, meaning that additional safety and effectiveness data are needed to support a determination that a drug product containing one of these active ingredients would be GRASE for use as a consumer antiseptic rub. Section 505G of the FD&C Act addresses nonprescription drugs marketed without an approved application. Under section 505G(a)(3) of the FD&C Act, drugs that were classified as Category III in a TFM that is the most recently applicable proposal or determination for such drug issued under 21 CFR Part 330 – and that were not classified as Category II for safety or effectiveness – are not required to have an approved application under section 505 in order to be marketed, as long as they are in conformity with the relevant conditions of use outlined in the applicable TFM, including the active ingredient, and comply with all other applicable requirements.
However, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA does not conform to the 1994 TFM, as further amended by the 2016 Consumer Antiseptic Rub proposed rule, nor any other TFM, proposed rule, or final rule, and does not meet the conditions under section 505G(a)(3) of the FD&C Act for marketing without an approved application under section 505.
According to the product label, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA purportedly contains the active ingredient ethyl alcohol (ethanol) 70% v/v. However, as previously discussed, FDA laboratory analysis revealed that a sample of MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA contained little to no ethanol. Such a product does not conform with the TFM and the applicable requirements for nonprescription drugs,2 nor is it consistent with the formulations described in FDA’s temporary policies for hand sanitizers during the COVID-19 public health emergency.3
FDA laboratory analyses also revealed that a sample of MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA contain significant concentrations of the undeclared ingredient methyl alcohol (methanol). Use of methanol as an active ingredient is not in conformance with the TFM, nor is it included in the formulations described in FDA’s Temporary Policy for Preparation of Certain Alcohol-Based Hand Sanitizer Products During the Public Health Emergency (COVID-19): Guidance for Industry.
Furthermore, methanol is not acceptable as an inactive ingredient in hand sanitizers. As previously discussed, methanol has significant and sometimes fatal toxic effects and, therefore, does not meet the requirements under 21 CFR 330.1(e) that that a product’s inactive ingredients be safe and suitable.4
Additionally, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA, is misbranded under sections 502(j), (a), (e) and (ee) of the FD&C Act, 21 U.S.C. 352(j), (a), (e) and (ee). It is misbranded under section 502(j) of the FD&C Act, 21 U.S.C. 352(j), because it is dangerous to health when used according to its labeling as a hand sanitizer. As previously stated, skin exposure to methanol could lead to systemic absorption, and substantial methanol exposure can potentially result in, among other things, blindness, permanent nervous system damage, and even death.
This hand sanitizer is misbranded under section 502(a) of the FD&C Act, 21 U.S.C 352(a), because its labeling is false or misleading. As noted above, MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is labeled to contain ethyl alcohol 70% v/v. However, FDA laboratory analysis revealed that a sample of this product detained at the border contains little to no ethyl alcohol and a significant concentration of methyl alcohol (methanol), an ingredient that is not declared on the product label. Section 201(n) of the FD&C Act, 21 U.S.C. 321(n), provides that “in determining whether the labeling or advertising is misleading there shall be taken into account . . . not only representations made or suggested . . . but also the extent to which the labeling or advertising fails to reveal facts material in the light of such representations or material with respect to consequences which may result. . ..” Thus, the misleading representation of the concentration of the active ingredient ethyl alcohol (ethanol) and the failure of the labeling to disclose the presence of the methyl alcohol (methanol) in the product, causes this product to be misbranded under section 502(a) of the FD&C Act, 21 U.S.C. 352(a). The failure of this product to list methanol as an ingredient on its label causes it to be misbranded under section 502(e)(1)(A) of the FD&C Act, 21 U.S.C. 352(e)(1)(A).
Lastly, this product is misbranded under section 502(ee) of the FD&C Act, 21 U.S.C. 352(ee) because MEDICALLY MINDED Hand Sanitizer Gel ANTIMICROBIAL FORMULA is a nonprescription drug subject to section 505G of the FD&C Act, 21 U.S.C. 355h, but does not comply with the requirements for marketing under that section and is not the subject of an application approved under section 505 of the FD&C Act, 21 U.S.C. 355.
The introduction or delivery for introduction of a misbranded drug into interstate commerce is prohibited under section 301(a) of the FD&C Act, 21 U.S.C. 331(a).
3CGMP Consultant Recommended
1 paragraph
Based upon the nature of the violations we identified at your firm, we strongly recommend engaging a consultant qualified, as set forth in 21 CFR 211.34, to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. We also recommend that the qualified consultant perform a comprehensive audit of your entire operation for CGMP compliance and that the consultant evaluates the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA. Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.
4Conclusion
8 paragraphs
The violations cited in this letter are not intended to be an all-inclusive list of violations associated with your drug products. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.
Note that FDA placed all drugs and drug products manufactured by your firm on Import Alert 66-78 on August 21, 2020, as the methods used in and controls used for the manufacture, processing, packing, or holding of these products do not appear to conform to current good manufacturing practice within the meaning of section 501(a)(2)(B) of the FD&C Act. Drugs and drug products that appear to be adulterated or misbranded may be detained or refused admission without physical examination.
All drugs and drug products manufactured by your firm may remain listed on this import alert until there is evidence establishing that the conditions that gave rise to the appearance of a violation have been resolved, and the Agency has confidence that future entries will be in compliance with the Act. This may include an inspection prior to the agency considering the appearance of adulteration to be addressed.
If you decide you want to manufacture drugs for the United States in the future, request a Regulatory Meeting to discuss corrective actions.
Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to any violations.
This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot do so within 15 working days, state your reasons for delay and your schedule for completion.
Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov
Identify your response with FEI 3016940656 and ATTN: Marisa Heayn
Citations and trends
Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.
Regulations
Also cited: 21 CFR 330
Issue types
Record details
- Issuing center
- Center for Drug Evaluation and Research
- Issuing office
- Center for Drug Evaluation and Research
- Location
- Tlaquepaque, Jal., Mexico
- Letter posted date
- Jan 26, 2021
- Letter issue date
- Jan 25, 2021
- Addressed to
- Not recorded
- Inspection dates
- Not recorded
- Response window
- Not verified in this snapshot. Consult the original letter.
- Record length
- 2,859 words · 0 recorded redactions
- Published status
- No published close-out
- Original letter
- View on FDA.gov (opens in a new tab)
- Dataset last checked
- Nov 11, 2026 · How this is built
A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.