Drugs

Guangzhou Baiyunshan Jingxiutang Pharmaceutical Co. Ltd.

FDA issued a warning letter to Guangzhou Baiyunshan Jingxiutang Pharmaceutical Co. Ltd. (Foshan Shi, Guangdong Sheng, China) on Aug 1, 2024, citing 21 CFR 211.160 and 21 CFR 211.22. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “You failed to establish appropriate release specifications and analytical testing procedures for critical quality attributes for the drug products you manufacture.”

Foshan Shi, Guangdong Sheng, ChinaIssued Aug 1, 2024Posted Aug 6, 2024No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
3 findings · 2 issue types
Response due
Not stated in the letter
FDA asks for
6 actions
Named as possible actions
Refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Laboratory controls & testing · 21 CFR 211.160(b)Drug products lacked appropriate release specifications and testing for all active ingredients, with only a single assay for one ingredient despite two listed.
You failed to establish appropriate release specifications and analytical testing procedures for critical quality attributes for the drug products you manufacture. For example, while the label for your over-the-counter (OTC) drug product (b)(4) lists two active ingredients, (b)(4), your certificate of analysis (COA) indicates only a single assay specification and result for (b)(4).
02Laboratory controls & testing · 21 CFR 211.160(b)Component (b)(4) lacked specifications for objectionable microorganisms, with only total aerobic microbial count tested.
You lacked appropriate specifications to ensure the (b)(4) used as a component in your drug products is suitable for the intended use of your drug products. Specifically, you only tested for total aerobic microbial count and did not perform any testing for objectionable microorganisms on your (b)(4).
03Quality unit & oversight · 21 CFR 211.22(a)Quality unit failed to exercise authority over laboratory controls and overall manufacturing oversight.
The records and information you provided demonstrate that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. Specifically, your QU did not adequately exercise its authority over the establishment of controls in your Laboratory System.

Additional FDA passages

2 extracted findings

Selected FDA passages, not the complete letter.

01

Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).

02

Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

What FDA requested

  • A comprehensive assessment of your laboratory practices, procedures, methods, equipment, documentation, and analyst competencies. Based on this review, provide a detailed plan to remediate and evaluate the effectiveness of your laboratory system.
  • A list of chemical and microbiological specifications, including test methods, used to analyze each lot of your drug products before a lot disposition decision.
  • An action plan and timelines for conducting full chemical and microbiological testing of retain samples to determine the quality of all batches of drug product distributed to the United States that are within expiry as of the date of this letter.
  • A summary of all results obtained from testing retain samples from each batch. If such testing reveals substandard quality drug products, take rapid corrective actions, such as notifying customers and product recalls.
  • A procedure governing your program for ongoing control, maintenance, and monitoring that ensures the system consistently produces (b)(4) that meets (b)(4), USP monograph specifications and appropriate microbial limits.
  • A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to: A determination of whether procedures used by your firm are robust and appropriate; Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices; A complete and final review of each batch and its related information before the QU disposition decision; Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products.

FDA Warning Letter

40 paragraphs · 3 sections

Text as published on FDA.gov, retrieved Sep 8, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedAugust 1, 2024
AddressedDear Mr. Cheng

1Introduction

26 paragraphs

The U.S. Food and Drug Administration (FDA) inspected your drug manufacturing facility, Guangzhou Baiyunshan Jingxiutang Pharmaceutical Co. Ltd., FEI 3006010954, at 249 Poyang Road, Huangqi, Dali Town, Nanhai District, Foshan City, Guangdong, China, from December 4 to 8, 2023.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).

We reviewed your January 2, 2024 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.

During our inspection, our investigator observed specific violations including, but not limited to, the following:

1. Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).

Drug Products Lacked Appropriate Specifications

You failed to establish appropriate release specifications and analytical testing procedures for critical quality attributes for the drug products you manufacture. For example, while the label for your over-the-counter (OTC) drug product (b)(4) lists two active ingredients, (b)(4), your certificate of analysis (COA) indicates only a single assay specification and result for (b)(4). You are responsible for ensuring you have scientifically sound specifications and test methods used to determine drug quality before release.

In your response, you state your drug product (b)(4) is in “accordance with” Chinese pharmacopoeia, and that the total (b)(4) (which you state includes “(b)(4), etc.”) is determined by “repeated tests.” You also state you will explore (b)(4) and (b)(4) content testing in accordance with U.S. laws and regulations.

Your response is inadequate because you did not provide specific details, such as a timeline for implementation, protocols, or test methods with updated specifications. In your response to our request for additional information on the test methods and specifications for your drug products, you stated you intend to carry out a separate study on the active component of your (b)(4) drug product, but did not provide the requested information.

Inadequate (b)(4) Testing

You lacked appropriate specifications to ensure the (b)(4) used as a component in your drug products is suitable for the intended use of your drug products. Specifically, you only tested for total aerobic microbial count and did not perform any testing for objectionable microorganisms on your (b)(4). In addition, your procedure did not specify the need for microbial identification of (b)(4) system sample isolates.

In your response, you state you “studied the USP and consulted the relevant standards” and will specifically test for Burkholderia cepacia complex in your (b)(4).

Your response is inadequate because it is unclear if you will adhere to United States Pharmacopoeia (USP) compendial methods for testing your (b)(4) sample and do not indicate you will test for objectionable microorganisms in addition to B. cepacia.

In response to this letter, provide:

A comprehensive assessment of your laboratory practices, procedures, methods, equipment, documentation, and analyst competencies. Based on this review, provide a detailed plan to remediate and evaluate the effectiveness of your laboratory system.

A list of chemical and microbiological specifications, including test methods, used to analyze each lot of your drug products before a lot disposition decision.

o An action plan and timelines for conducting full chemical and microbiological testing of retain samples to determine the quality of all batches of drug product distributed to the United States that are within expiry as of the date of this letter. o A summary of all results obtained from testing retain samples from each batch. If such testing reveals substandard quality drug products, take rapid corrective actions, such as notifying customers and product recalls.

A procedure governing your program for ongoing control, maintenance, and monitoring that ensures the system consistently produces (b)(4) that meets (b)(4), USP monograph specifications and appropriate microbial limits.

2. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

The records and information you provided demonstrate that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. Specifically, your QU did not adequately exercise its authority over the establishment of controls in your Laboratory System.

Your QU is responsible for fully exercising its authority and responsibilities. FDA is concerned that your QU may also not be conducting appropriate oversight regarding other CGMP operations, including Production, Facilities & Equipment, Laboratory Controls, and Packaging & Labelling Systems.

See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

In response to this letter, provide:

A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to:

o A determination of whether procedures used by your firm are robust and appropriate o Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices o A complete and final review of each batch and its related information before the QU disposition decision o Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products

2CGMP Consultant Recommended

1 paragraph

Because you failed to correct repeat violations, you should engage a consultant qualified as set forth in 21 CFR 211.34 to assist your firm in meeting CGMP requirements. Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

3Conclusion

5 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may reinspect to verify that you have completed corrective actions to any violations.

Failure to address any violations may also result in the FDA refusing admission of articles manufactured at Guangzhou Baiyunshan Jingxiutang Pharmaceutical Co. Ltd., located at 249 Poyang Road, Huangqi, Dali Town, Nanhai District, Foshan City, Guangdong, China into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission, in that the methods and controls used in their manufacture do not appear to conform to CGMP within the meaning of section 501(a)(2)(B) of the FD&C Act, 21 U.S.C. 351(a)(2)(B).

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3006010954 and ATTN: Marisa Heayn.

Sincerely, /S/

Francis Godwin Director Office of Manufacturing Quality Office of Compliance Center for Drug Evaluation and Research

CC: (b)(4)

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Also cited: 21 CFR 210

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Foshan Shi, Guangdong Sheng, China
Letter posted date
Aug 6, 2024
Letter issue date
Aug 1, 2024
Addressed to
Legal Representative and Chairman of the Board
Inspection dates
Dec 4, 2023
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,336 words · 18 recorded redactions
Published status
No published close-out
FDA reference
320-24-54
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.