Fresh Farms LLC
FDA issued a warning letter to Fresh Farms LLC (Montebello, CA, United States) on Apr 19, 2022, citing 21 CFR 211.22, 21 CFR 211.84, 21 CFR 211.165 and 21 CFR 211.188. Subject: CGMP, Finished Pharmaceuticals, Adulterated.
From the letter: “Your firm failed to establish an adequate quality unit with responsibilities to ensure adequate oversight for the manufacture of your OTC drug products.”
At a glance
What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.
- Violations
- 4 findings · 4 issue types
- Response due
- Not stated in the letter
- FDA asks for
- 2 actions
- Named as possible actions
- Seizure, injunction
- Issued by
- Division of Pharmaceutical Quality Operations IV · Office of Inspections and Investigations
- Published status
- No close-out recorded
AI assisted findings
Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.
01Quality unit & oversight · 21 CFR 211.22(a)Firm failed to establish an adequate quality unit and to ensure responsibilities were in writing and fully followed; batch release was not adequately documented.
Your firm failed to establish an adequate quality unit with responsibilities to ensure adequate oversight for the manufacture of your OTC drug products. For example, you failed to ensure that the responsibilities of the quality unit are in writing and fully followed, that your products specifications are established and approved, and that the final review of each batch and its related information are adequately documented and completed before release and distribution.
02Components & suppliers · 21 CFR 211.84(a)Incoming components, including ethanol (API), were not tested prior to use.
You failed to sample, test, and examine components used in the manufacture of your OTC drugs including ethanol which is used as an active pharmaceutical ingredient (API) in the manufacture of (b)(4) Hand Sanitizer drug product. During the inspection, you stated that you did not test your incoming raw materials prior to use.
03Laboratory controls & testing · 21 CFR 211.165(a)Release testing for identity and strength of active ingredients was not performed on any batches.
You failed to perform release testing for batches of (b)(4) Hand Sanitizer labeled as containing ethanol. During the inspection, you stated that no release testing was performed on your drug products.
04Records & data integrity · 21 CFR 211.188No executed batch records were prepared for any drug product batches.
You lacked executed batch records for batches of (b)(4) Hand Sanitizer drug product you manufactured. During the inspection, you stated that no batch records were prepared.
Additional FDA passages
6 extracted findingsSelected FDA passages, not the complete letter.
Failure to establish an adequate quality unit and the responsibilities and procedures applicable to the quality control unit are not in writing and fully followed (21 CFR 211.22(a) and 211.22(d)).
Your firm failed to withhold from use each lot of components, drug product containers, and closures until the lot had been sampled, tested, or examined, as appropriate, and released for use by the quality control unit (21 CFR 211.84(a))
Your firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release (21 CFR 211.165(a)).
You failed to perform release testing for batches of **(b)(4)** Hand Sanitizer labeled as containing ethanol. During the inspection, you stated that no release testing was performed on your drug products. Drug products must be tested for identity, strength, quality, and purity prior to release. Testing is essential to ensure that the drug products you manufacture conform to all pre-determined quality attributes that are appropriate for their intended use, including microbiological specifications.
Your firm failed to prepare batch production and control records with complete information relating to the production and control of each batch of drug product produced (21 CFR 211.188).
Failure to address violations may also cause the FDA to withhold issuance of Export Certificates. The FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.
What FDA requested
- Specify what you have done to address any violations and to prevent their recurrence.
- If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.
FDA Warning Letter
39 paragraphs · 7 sectionsText as published on FDA.gov, retrieved Nov 2, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)
1Introduction
5 paragraphs
The U.S. Food and Drug Administration inspected your drug manufacturing facility, Fresh Farms LLC, FEI 3016866993, at 3360 North Las Vegas Blvd Unit E024, Las Vegas, NV 89115, from November 8 to November 11, 2021.
This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).
Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).
We reviewed your November 23, 2021 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence. Your response is inadequate because you failed to provide supportive documentation for evaluation or adequate evidence of corrective actions taken to bring your operations into compliance with CGMP. In addition, your response claims that you comply with various CGMP requirements. However, this contradicts the statements you made during the inspection.
During our inspection, our investigators observed specific violations including, but not limited to, the following.
21. Failure to establish an adequate quality unit and the responsibilities and procedures applicable to the quality control unit are not in writing and fully followed (21 CFR 211.22(a) and 211.22(d)).
7 paragraphs
Your firm manufactures over the counter (OTC) Hand Sanitizer1 drug products including (b)(4) Hand Sanitizer. Your firm’s quality systems are inadequate. Your firm failed to establish an adequate quality unit with responsibilities to ensure adequate oversight for the manufacture of your OTC drug products. For example, you failed to ensure that the responsibilities of the quality unit are in writing and fully followed, that your products specifications are established and approved, and that the final review of each batch and its related information are adequately documented and completed before release and distribution.
An adequate quality unit overseeing all manufacturing operations is necessary to consistently ensure drug quality. See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.
2. Your firm failed to withhold from use each lot of components, drug product containers, and closures until the lot had been sampled, tested, or examined, as appropriate, and released for use by the quality control unit (21 CFR 211.84(a))
You failed to sample, test, and examine components used in the manufacture of your OTC drugs including ethanol which is used as an active pharmaceutical ingredient (API) in the manufacture of (b)(4) Hand Sanitizer drug product. During the inspection, you stated that you did not test your incoming raw materials prior to use. You told our investigators that your customer, “(b)(4),” was responsible for sourcing materials, including ethanol. However, this does not absolve you of your responsibility as the manufacturer to sample, test, and examine drug components prior to use to assure adequate quality, including testing for the presence of methanol in ethanol, before use in production.
The use of ethanol contaminated with methanol has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Policy for Testing of Alcohol (Ethanol) and Isopropyl Alcohol for Methanol, Including During the Public Health Emergency (COVID-19) to help you meet the CGMP requirements when manufacturing drugs containing ethanol at https://www.fda.gov/media/145262/download.
3. Your firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release (21 CFR 211.165(a)).
You failed to perform release testing for batches of (b)(4) Hand Sanitizer labeled as containing ethanol. During the inspection, you stated that no release testing was performed on your drug products. Drug products must be tested for identity, strength, quality, and purity prior to release. Testing is essential to ensure that the drug products you manufacture conform to all pre-determined quality attributes that are appropriate for their intended use, including microbiological specifications.
34. Your firm failed to prepare batch production and control records with complete information relating to the production and control of each batch of drug product produced (21 CFR 211.188).
1 paragraph
You lacked executed batch records for batches of (b)(4) Hand Sanitizer drug product you manufactured. During the inspection, you stated that no batch records were prepared. You also stated that your employees knew the formulation and final concentration of the hand sanitizer and therefore, production was to be performed in the same manner every time to yield finished product of the desired concentration. Without executed batch records, you cannot verify that each significant step of your drug production process is completed as intended to assure uniformity from batch to batch, including but not limited to weights and measures of components, using correct equipment, adhering to all critical processing parameters, and statement of yields. Additionally, you are unable to determine if errors have occurred and whether such errors may impact product quality or patient safety, and traceability back to the individual batches.
4Drug Production Ceased
1 paragraph
We acknowledge your commitment to cease production of drugs at this facility. If you plan to resume manufacturing drugs, notify this office before resuming your operations.
5Responsibilities as a Contractor
2 paragraphs
Drugs must be manufactured in conformance with CGMP. The FDA is aware that many drug manufacturers use independent contractors such as production facilities, testing laboratories, packagers, and labelers. The FDA regards contractors as extensions of the manufacturer.
You are responsible for the quality of drugs you produce as a contract facility regardless of agreements in place with product owners. You are required to ensure that drugs are made in accordance with section 501(a)(2)(B) of the FD&C Act for safety, identity, strength, quality, and purity. See FDA’s guidance document Contract Manufacturing Arrangements for Drugs: Quality Agreements at https://www.fda.gov/media/86193/download.
6CGMP Consultant Recommended
1 paragraph
If your firm intends to resume manufacturing drugs for the U.S. market, we strongly recommend engaging a consultant qualified as set forth in 21 CFR 211.34 to assist your firm in meeting CGMP requirements. Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.
7Conclusion
8 paragraphs
The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility, in connection with your product(s). You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.
Correct any violations promptly. Failure to promptly and adequately address this matter may result in regulatory or legal action without further notice including, without limitation, seizure and injunction. Unresolved violations may also prevent other Federal agencies from awarding contracts.
Failure to address violations may also cause the FDA to withhold issuance of Export Certificates. The FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.
This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.
Please send your electronic reply to ORAPHARM4_Responses@FDA.HHS.GOV or mail your reply to:
CDR Steven E. Porter, Jr. Director, Division of Pharmaceutical Quality Operations IV U.S. Food & Drug Administration 19701 Fairchild Road Irvine, California 92612-2506
Please identify your responses with the unique identifier: CMS 623723
If you have questions regarding the contents of this letter, please contact Andrew Haack, Compliance Officer by telephone at 206-340-8212 or email at Andrew.Haack@fda.hhs.gov.
Citations and trends
Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.
Regulations
Also cited: 21 CFR 210
Issue types
Record details
- Issuing center
- Office of Inspections and Investigations
- Issuing office
- Division of Pharmaceutical Quality Operations IV
- Location
- Montebello, CA, United States
- Letter posted date
- Apr 26, 2022
- Letter issue date
- Apr 19, 2022
- Addressed to
- CEO
- Inspection dates
- Nov 8, 2021 to Nov 11, 2021
- Response window
- Not verified in this snapshot. Consult the original letter.
- Record length
- 1,568 words · 8 recorded redactions
- Published status
- No published close-out
- FDA reference
- 623723
- Original letter
- View on FDA.gov (opens in a new tab)
- Dataset last checked
- Nov 11, 2026 · How this is built
A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.