FDA Warning Letter Explorer
Drugs · Letter issue date: May 14, 2025

Evi Labs LLC

6 extracted findings · 4 model-assigned issue types

FDA source excerpt, selected passage

You released batches of drug products for distribution without conducting adequate strength and identity testing.

Findings and supporting evidence

Model-assisted readings, not an exhaustive interpretation. Compare with the extracted source findings below.

Laboratory controls & testing21 CFR 211.165(a)

Released batches without adequate strength and identity testing; some results exceeded specifications and monograph limits.

Supporting FDA text
Source excerpt · automated text-match check

You released batches of drug products for distribution without conducting adequate strength and identity testing.

Laboratory controls & testing21 CFR 211.160(b)

Microbiological specifications were set too high, leading to release of products exceeding microbial quality limits.

Supporting FDA text
Source excerpt · automated text-match check

your microbiological specifications were set at (b)(4) times greater than the United States Pharmacopoeia (USP) guidance for each of the dosage forms. This resulted in your approval and release of antiperspirant drug products which had exceeded the microbiological quality for your products intended use.

Facilities & equipment21 CFR 211.100(a)

Water system was not validated or adequately designed, risking biofilm and poor water quality.

Supporting FDA text
Source excerpt · automated text-match check

You failed to adequately validate your water production process to ensure it was consistently producing water of appropriate quality for its intended use, including the manufacture of oral and topical drug products.

Production & process controls21 CFR 211.100(a)

Manufacturing processes were not validated, and critical process steps and equipment were not adequately controlled.

Supporting FDA text
Source excerpt · automated text-match check

You have not validated the processes used to manufacture your OTC drug products.

Quality unit & oversight21 CFR 211.22(a)

Quality unit failed to ensure quality of components, investigations, computer controls, stability testing, and rejected nonconforming products.

Supporting FDA text
Source excerpt · automated text-match check

your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations.

Findings extracted from the letter

Selected FDA passages, not the complete letter.

01
Your firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release (21 CFR 211.165(a)).
02
Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).
03
Your firm failed to establish adequate microbiological specifications for your OTC drug products including **(b)(4)** oral suspension and topical antiperspirant deodorants. For example, your microbiological specifications were set at **(b)(4)** times greater than the United States Pharmacopoeia (USP) guidance for each of the dosage forms. This resulted in your approval and release of antiperspirant drug products which had exceeded the microbiological quality for your products intended use.
04
Your firm failed to establish adequate written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess, and your firm’s quality control unit did not review and approve those procedures, including any changes (21 CFR 211.100(a)).
05
Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products and the authority to review production records to assure that no errors have occurred or, if errors have occurred, that they have been fully investigated (21 CFR 211.22(a)).
06
Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

What FDA requested

Model-assisted summary. Consult the letter for complete requests and conditions.

  • A list of chemical specifications, including test methods, used to analyze each lot of your drug products before a lot disposition decision.
  • An action plan and timelines for conducting full chemical testing of retain samples to determine the quality of all batches of drug product distributed to the United States that are within expiry as of the date of this letter.
  • A summary of all results obtained from testing retain samples from each batch. If such testing reveals substandard quality drug products, take rapid corrective actions, such as notifying customers and product recalls.
  • A comprehensive independent assessment of your laboratory practices, procedures, methods, equipment, documentation, and analyst competencies. Based on this review, provide a detailed plan to remediate and evaluate the effectiveness of your laboratory system.
  • A list of microbial specifications, including test methods, used to analyze each lot of your drug products before a lot disposition decision.
  • An action plan and timelines for conducting microbiological testing of retain samples to determine the quality of all batches of drug product distributed to the United States that are within expiry as of the date of this letter.
  • A summary of all results obtained from testing retain samples from each batch. If such testing reveals substandard quality drug products, take rapid corrective actions, such as notifying customers and product recalls.
  • Clarification on whether you intend to continue production for each of your OTC drug products.

Sections and clauses cited

As cited in this historical letter, not a statement of current regulatory requirements.

Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.