Drugs

Dough-To-Go, Inc.

FDA issued a warning letter to Dough-To-Go, Inc. (Santa Clara, CA, United States) on May 12, 2026, citing 21 CFR 117.135, 21 CFR 117.20, 21 CFR 117.35 and 21 CFR 117.40. Subject: CGMP, Hazard Analysis, Risk-Based Preventive Controls for Food, Adulterated.

From the letter: “the FDA investigator observed a packaging employee using a frayed, ripped towel to wipe the surface of a scratched wooden packaging table and then wiping their gloved hands on the same towel.”

Santa Clara, CA, United StatesIssued May 12, 2026Posted Jun 2, 2026No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
6 findings · 2 issue types
Response due
Fifteen (15) working days of receipt
FDA asks for
4 actions
Named as possible actions
Seizure, injunction
Issued by
Human Foods Program
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Production & process controls · 21 CFR 117.135(a)(1)A packaging employee used a frayed, ripped towel to wipe a scratched wooden table and then their gloved hands before hand-packaging RTE products, contrary to the GMP policy.
the FDA investigator observed a packaging employee using a frayed, ripped towel to wipe the surface of a scratched wooden packaging table and then wiping their gloved hands on the same towel. Without removing or changing their gloves, the employee immediately proceeded to hand-package RTE products.
02Production & process controls · 21 CFR 117.135(a)(1)Employees did not apply sanitizer after donning gloves and before touching RTE products, as required by the GMP policy.
the FDA investigator did not observe any employees apply sanitizer after donning their gloves and before touching RTE products.
03Production & process controls · 21 CFR 117.135(a)(1)Spilled nuts remained on the freezer floor beside cases of macadamia nuts and almonds, indicating failure to control allergen cross-contact.
the FDA investigator observed spilled nuts on the floor of the freezer, beside cases holding macadamia nuts and almonds. During the inspection, your firm began to clean the spilled nuts, but the FDA investigator noted there were still some nuts on the floor as of November 7, 2025.
04Facilities & equipment · 21 CFR 117.20(a)Overgrown weeds, vegetation, and unused equipment outside the building could attract pests, and a trap showed heavy mice activity.
the FDA investigator observed overgrown weeds, other vegetation, and unused equipment stored directly outside the building (near the employee entrance and outdoor break area). Overgrown vegetation and equipment that is not properly stored could constitute an attractant, breeding place, or harborage for pests.
05Facilities & equipment · 21 CFR 117.35(c)Gnats, a rodent excreta pellet, and a gap in the warehouse dock door were observed, indicating failure to exclude pests.
the FDA investigator observed at least three apparent gnats on a cookie decorating table and one apparent rodent excreta pellet on the lower shelf of the dry storage rack. The FDA investigator also observed an approximate (b)(4) gap in the top of the warehouse dock door, creating a potential pest entry point.
06Facilities & equipment · 21 CFR 117.40(a)(1)The raw dough conveyor belt had fraying edges, a repeat observation from prior inspections, and could shed into products.
the FDA investigator observed that the raw dough conveyor belt had two areas of fraying edges, measuring approximately (b)(4) long. Fraying edges of conveyor belts could become harborage points for contaminants and could shed into products such as the Linzer Heart cookies.

What FDA requested

  • Notify FDA in writing within 15 working days of specific steps taken to address violations.
  • Include an explanation of each step to prevent recurrence and copies of related documentation.
  • State reason for delay and time frame if corrective actions cannot be completed within 15 working days.
  • Include reasoning and supporting information if products are believed not in violation.

FDA Warning Letter

35 paragraphs · 3 sections

Text as published on FDA.gov, retrieved Oct 27, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedMay 12, 2026
Sent toRe: CMS # 727845
AddressedDear Ms. Hamel-Dailey

1Introduction

3 paragraphs

The United States Food and Drug Administration (FDA) inspected your manufacturing facility for baked goods and unbaked doughs, located at 3535 De La Cruz Blvd, Santa Clara, CA 95054-2112 from October 29 through November 7, 2025. During our inspection of your facility, an FDA investigator found serious violations of the Current Good Manufacturing Practice, Hazard Analysis, and Risk-Based Preventive Controls for Human Food regulation (CGMP & PC rule), Title 21, Code of Federal Regulations, Part 117 (21 CFR Part 117).

Based on FDA's inspectional findings, we have determined that your Linzer Heart cookies are adulterated within the meaning of section 402(a)(4) of the Federal Food, Drug, and Cosmetic Act (the Act) [21 U.S.C. § 342(a)(4)], in that they were prepared, packed, or held under insanitary conditions whereby they may have become contaminated with filth, or whereby they may have been rendered injurious to health. In addition, failure of the owner, operator, or agent in charge of a covered facility to comply with the preventive controls provisions of the CGMP & PC rule (located in Subparts A, C, D, E, F, and G of Part 117) is prohibited by section 301(uu) of the Act [21 U.S.C. § 331(uu)]. You may find the Act and FDA's regulations through links on FDA's website at www.fda.gov.

At the conclusion of the inspection, the FDA investigator issued your facility a Form FDA 483 (FDA-483), Inspectional Observations. To date, we have not received your response to the issued FDA-483. Based on our review of the inspectional findings, we are issuing this letter to advise you of FDA’s concerns and to provide detailed information describing the findings at your facility.

2Hazard Analysis and Risk-Based Preventive Controls (21 CFR Part 117, Subpart C)

8 paragraphs

1. You did not implement your preventive controls to provide assurances that any hazards requiring a preventive control will be significantly minimized or prevented and the food manufactured, processed, packed, or held by your facility will not be adulterated under section 402 of the Act, as required by 21 CFR 117.135(a)(1).

a. You did not implement your sanitation preventive control for the environmental pathogens hazard. Your hazard analysis for your baked goods appropriately identifies recontamination with environmental pathogens as a hazard requiring a preventive control at post-bake steps such as (b)(4). At these steps, the baked goods are exposed to the environment.

However, you did not follow your facility’s sanitation preventive controls to control the hazard of recontamination with environmental pathogens, as follows:

1) Your GMP Employee Policy1 (Doc #(b)(4), Section IV.E.8) states: “(b)(4).” However, on October 29, 2025, the FDA investigator observed a packaging employee using a frayed, ripped towel to wipe the surface of a scratched wooden packaging table and then wiping their gloved hands on the same towel. Without removing or changing their gloves, the employee immediately proceeded to hand-package RTE products.

2) Your GMP Employee Policy (Doc #(b)(4)) states (b)(4). However, the FDA investigator did not observe any employees apply sanitizer after donning their gloves and before touching RTE products. During the inspection, you stated that within 30 days, employees would be re-trained on sanitizer use. We will evaluate the adequacy of your corrective action during our next inspection.

b. You did not implement your allergen preventive control for the allergen cross-contact hazard.

Your hazard analysis for your baked goods appropriately identifies allergen cross-contact as a hazard requiring a preventive control at steps such as (b)(4). Your firm handles allergens including wheat, eggs, milk, soy, peanuts, and tree nuts (such as macadamia nuts, almonds, and pecans) on food-contact surfaces of shared processing equipment.

However, you did not follow your procedures to control the hazard of allergen cross-contact. Your Allergen Management SOP2 (Doc #(b)(4)) states (b)(4). However, on October 29, 2025, the FDA investigator observed spilled nuts on the floor of the freezer, beside cases holding macadamia nuts and almonds. During the inspection, your firm began to clean the spilled nuts, but the FDA investigator noted there were still some nuts on the floor as of November 7, 2025. You stated (b)(4). We will evaluate the adequacy of your corrective actions during our next inspection.

3Current Good Manufacturing Practice Requirements (21 CFR Part 117, Subpart B)

13 paragraphs

1. You did not keep the grounds about your plant in a condition that would protect against the contamination of food, as required by 21 CFR 117.20(a).

On November 3, 2025, the FDA investigator observed overgrown weeds, other vegetation, and unused equipment stored directly outside the building (near the employee entrance and outdoor break area). Overgrown vegetation and equipment that is not properly stored could constitute an attractant, breeding place, or harborage for pests. A review of Pest Control Reports dated October 22, 2025, documented heavy mice activity in exterior trap X4, which is located near the employee entrance and was hidden in the overgrown vegetation. During the inspection, you stated (b)(4). We will evaluate the adequacy of your corrective actions during our next inspection.

2. You did not take effective measures to exclude pests from the manufacturing, processing, packing, and holding areas and to protect against the contamination of food on the premises by pests, as required by 21 CFR 117.35(c).

On October 29, 2025, the FDA investigator observed at least three apparent gnats on a cookie decorating table and one apparent rodent excreta pellet on the lower shelf of the dry storage rack. The FDA investigator also observed an approximate (b)(4) gap in the top of the warehouse dock door, creating a potential pest entry point. During the inspection, you removed the apparent rodent excreta pellet and cleaned the lower shelf of the dry storage rack. You also stated (b)(4). We will evaluate the adequacy of your corrective actions during our next inspection.

3. Your equipment and utensils were not adequately maintained to protect against contamination, as required by 21 CFR 117.40(a)(1).

On 10/29/2025, the FDA investigator observed that the raw dough conveyor belt had two areas of fraying edges, measuring approximately (b)(4) long. Fraying edges of conveyor belts could become harborage points for contaminants and could shed into products such as the Linzer Heart cookies.

This is a repeat observation from the previous FDA inspections conducted on March 18, 2021, and May 22, 2018, where the same conveyor belt was cited as worn and frayed. During the 2021 inspection, your President stated that a new replacement conveyor belt had arrived but had not been installed due to the arduous and expensive task of installing the belt. During the most recent inspection, you stated (b)(4). We will evaluate the adequacy of your corrective action during our next inspection.

4. You did not clean and sanitize your utensils or equipment in a manner that protects against contamination of food, food-contact surfaces, or food packaging materials, as required by 21 CFR 117.35(a).

According to your Sanitizer Solution Log Sheet, your (b)(4). On October 29, 2025, the FDA investigator observed employees performing sanitation on utensils in a three-compartment sink (water rinse, soap and scrubbing, and sanitizer dip). The FDA investigator asked your President to test the quat concentration in the sink-dip (third compartment) using test strips. However, the test strip showed 0 ppm quat in the sink-dip (no color change). During the inspection, you stated (b)(4). We will evaluate the adequacy of your corrective action during our next inspection.

This letter is not intended to be an all-inclusive statement of violations that may exist at your facility or in connection with your products. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. It is your responsibility to ensure that your firm complies with all requirements of federal law, including applicable FDA regulations.

This letter notifies you of our concerns and provides you an opportunity to address them. Failure to adequately address this matter may result in legal action including, without limitation, seizure, injunction, or administrative action for suspension of food facility registration if criteria and conditions warrant.

Response requested

Please notify FDA in writing, within fifteen (15) working days of receipt of this letter, of the specific steps you have taken to address any violations. Include an explanation of each step being taken to prevent the recurrence of violations, as well as copies of related documentation. If you cannot complete corrective actions within fifteen (15) working days, state the reason for the delay and the time within which you will do so. If you believe that your products are not in violation of the Act, include your reasoning and any supporting information for our consideration.

Please send your written response electronically to: HFP-OCE-ConventionalFoods@fda.hhs.gov, copying Kathryn Cutajar, Compliance Officer, at Kathryn.Cutajar@fda.hhs.gov. If you have any questions regarding this letter, you may contact Kathryn Cutajar, Compliance Officer, at Kathryn.Cutajar@fda.hhs.gov. Please reference CMS #727845 on any submissions and within the subject line of any emails to us.

Sincerely,/S/

Maria S. Knirk, JD MBADirectorOffice of EnforcementOffice of Compliance and EnforcementHuman Foods Program

_________________________

1 During the inspection, you indicated to the FDA investigator that the practices described in your GMP Employee Policy are part of your sanitation preventive controls.

2 During the inspection, you indicated to the FDA investigator that the practices described in your Allergen Management SOP are part of your allergen preventive controls.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

21 CFR 117.135Preventive controls2letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 117.135 →
020210202212023020240202512026
21 CFR 117.20Plant and grounds1letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 117.20 →
020210202202023020240202512026
21 CFR 117.35Sanitary operations2letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 117.35 →
020210202202023120240202512026
21 CFR 117.40Equipment and utensils1letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 117.40 →
020210202202023020240202512026

Also cited: 21 CFR 117

Issue types

Record details

Issuing center
Human Foods Program
Issuing office
Human Foods Program
Location
Santa Clara, CA, United States
Letter posted date
Jun 2, 2026
Letter issue date
May 12, 2026
Addressed to
Owner and Chief Executive Officer
Inspection dates
Nov 7, 2025
Response window
15 working days after receipt of this letter
Read the source clause
Please notify FDA in writing, within fifteen (15) working days of receipt of this letter, of the specific steps you have taken to address any violations.
Record length
1,548 words · 16 recorded redactions
Published status
No published close-out
FDA reference
727845
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.