Clean Solutions LLC
FDA issued a warning letter to Clean Solutions LLC (Clifton, NJ, United States) on Sep 6, 2024, citing 21 CFR 211.84, 21 CFR 211.165, 21 CFR 211.100, 21 CFR 211.22 and 4 more regulations. Subject: CGMP, Finished Pharmaceuticals, Adulterated.
From the letter: “Your firm failed to conduct at least one test to verify the identity of each component of a drug product.”
At a glance
What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.
- Violations
- 4 findings · 4 issue types
- Cited
- 21 CFR 211.84, 21 CFR 211.165, 21 CFR 211.100, 21 CFR 211.22, 21 CFR 211.166, 21 CFR 211.180, 21 CFR 211.67, 21 CFR 211.188
- Response due
- Not stated in the letter
- FDA asks for
- 4 actions
- Named as possible actions
- Seizure, injunction
- Issued by
- Division of Pharmaceutical Quality Operations I · Office of Inspections and Investigations
- Published status
- No close-out recorded
AI assisted findings
Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.
01Components & suppliers · 21 CFR 211.84(d)(1)Failed to conduct at least one identity test for each component and failed to validate supplier test analyses at appropriate intervals.
Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).
02Laboratory controls & testing · 21 CFR 211.165(a)Failed to perform appropriate laboratory testing for conformance to final specifications and for objectionable microorganisms prior to release.
Your firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release, and conduct for each batch of drug product, appropriate laboratory testing, as necessary, required to be free of objectionable microorganisms (21 CFR 211.165(a) and 211.165(b)).
03Production & process controls · 21 CFR 211.100(a)Failed to establish written production and process control procedures and failed to validate manufacturing processes and qualify equipment.
Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).
04Quality unit & oversight · 21 CFR 211.22Quality control unit failed to ensure compliance with CGMP, including procedures for complaints, change control, training, stability, product reviews, cleaning, and batch records.
Your firm’s quality control unit failed to exercise its responsibility to ensure drug products manufactured are in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).
Additional FDA passages
3 extracted findingsSelected FDA passages, not the complete letter.
Your firm failed to perform appropriate testing on your hand sanitizer and antibacterial hand soap drug products prior to release for distribution. Specifically, during the inspection, you stated that no chemical or microbiological analyses are performed on your finished drug products.
You failed to validate the processes used to manufacture your drug products. You also failed to qualify the equipment used to manufacture your drug products.
Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.
What FDA requested
- Clarify whether you intend to continue manufacturing drugs at this or any other facility.
- Engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and assist in meeting CGMP requirements if you continue manufacturing drugs.
- The qualified consultant should perform a comprehensive six-system audit of your entire operation for CGMP compliance.
- Evaluate the completion and efficacy of your corrective actions and preventive actions before pursuing resolution of your firm’s compliance status with FDA.
FDA Warning Letter
34 paragraphs · 3 sectionsText as published on FDA.gov, retrieved Oct 21, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)
1Introduction
19 paragraphs
The U.S. Food and Drug Administration (FDA) inspected your drug manufacturing facility, Clean Solutions LLC, FEI 3012305678, at 791 Paulison Ave., Suite 5, Clifton, NJ, from May 6 to 10, 2024.
This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).
Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).
We reviewed your May 29, 2024 response to our Form FDA 483 in detail. Your response is inadequate because you failed to provide supportive documentation for evaluation or adequate evidence of corrective actions taken to bring your operations into compliance with CGMP.
During our inspection, our investigators observed specific violations including, but not limited to, the following.
1. Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).
Your firm manufactures over-the-counter (OTC) topical drug products, such as antibacterial hand soaps containing benzalkonium chloride. You failed to perform adequate identity testing of each component lot used in the manufacture of your drug products. You also relied on your suppliers’ certificate of analysis (COA) without establishing the reliability of your component suppliers’ test analyses at appropriate intervals.
Without adequate testing, you do not have scientific evidence that the components conform to appropriate specifications before use in the manufacture of your drug products.
2. Your firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release, and conduct for each batch of drug product, appropriate laboratory testing, as necessary, required to be free of objectionable microorganisms (21 CFR 211.165(a) and 211.165(b)).
Your firm failed to perform appropriate testing on your hand sanitizer and antibacterial hand soap drug products prior to release for distribution. Specifically, during the inspection, you stated that no chemical or microbiological analyses are performed on your finished drug products.
Testing is essential to ensure that the drug products you manufacture conform to all pre-determined quality attributes appropriate for their intended use. Because you lacked adequate testing of each batch of your drug products, you do not know whether they conform to all appropriate finished product specifications and are suitable for release to consumers.
3. Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).
You failed to validate the processes used to manufacture your drug products. You also failed to qualify the equipment used to manufacture your drug products.
Process validation evaluates the soundness of design and state of control of a process throughout its lifecycle. Each significant stage of a manufacturing process must be designed appropriately and assure the quality of raw material inputs, in-process materials, and finished drugs. Process qualification studies determine whether an initial state of control has been established. Successful process qualification studies are necessary before commercial distribution. Thereafter, ongoing vigilant oversight of process performance and product quality is necessary to ensure that you maintain a stable manufacturing operation throughout the product lifecycle.
Without adequate process validation, incorporating all manufacturing inputs and parameters that can affect product quality, your firm lacks basic assurance that you can reproducibly deliver products that meet specifications. See FDA's guidance for industry, Process Validation: General Principles and Practices for general principles and approaches that the FDA considers appropriate elements of process validation at https://www.fda.gov/media/71021/download.
4. Your firm’s quality control unit failed to exercise its responsibility to ensure drug products manufactured are in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).
Your quality unit (QU) did not provide adequate oversight for the manufacture of your drug products. For example, your QU failed to ensure the following:
• Establishment of adequate procedures describing complaint handling, change control, and employee training procedures (21 CFR 211.22(d)). • Establishment of an adequate ongoing stability program (21 CFR 211.166(a)). • Performance of periodic (i.e., at least annual) product reviews (21 CFR 211.180(e)). • Adequate equipment cleaning and cleaning procedures, as well as appropriate cleaning validation (21 CFR 211.67(a) and 67(b)). • Appropriate batch production and control records that include documentation of the accomplishment of each significant step in manufacturing of your drug products (21 CFR 211.188(b)).
An adequate QU overseeing all manufacturing operations is necessary to consistently ensure drug quality. See FDA’s guidance document Quality Systems approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR parts 210 and 211 at https://www.fda.gov/media/71023/download.
2CGMP Consultant Recommended
3 paragraphs
In response to this letter, clarify whether you intend to continue manufacturing drugs at this or any other facility.
Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if you continue manufacturing drugs. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA.
Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.
3Conclusion
5 paragraphs
The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. Correct any violations promptly. Failure to promptly and adequately address this matter may result in regulatory or legal action without further notice including, without limitation, seizure and injunction. Unresolved violations may also prevent other Federal agencies from awarding contracts.
Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.
This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.
Send your electronic response to orapharm1_responses@fda.hhs.gov. Your written notification should refer to Warning Letter CMS # 686995 and include FEI: 3012305678.
If you have any questions, contact Compliance Officer Barbara Wilimczyk-Macri at barbara.wilimczyk@fda.hhs.gov.
Citations and trends
Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.
Regulations
Also cited: 21 CFR 210
Issue types
Record details
- Issuing center
- Office of Inspections and Investigations
- Issuing office
- Division of Pharmaceutical Quality Operations I
- Location
- Clifton, NJ, United States
- Letter posted date
- Oct 1, 2024
- Letter issue date
- Sep 6, 2024
- Addressed to
- President
- Inspection dates
- May 6, 2024
- Response window
- Not verified in this snapshot. Consult the original letter.
- Record length
- 1,274 words · 0 recorded redactions
- Published status
- No published close-out
- FDA reference
- 686995
- Original letter
- View on FDA.gov (opens in a new tab)
- Dataset last checked
- Nov 11, 2026 · How this is built
A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.