Drugs

Chartwell Pharmaceuticals Congers, LLC

FDA issued a warning letter to Chartwell Pharmaceuticals Congers, LLC (Congers, NY, United States) on Nov 13, 2026, citing 21 CFR 211.192, 21 CFR 211.160, 21 CFR 211.42, 21 CFR 211.176 and 5 more regulations. Subject: CGMP, Finished Pharmaceuticals, Adulterated, Unapproved New Drug.

From the letter: “Your firm delayed, denied, limited, or refused the FDA inspection based on certain actions in relation to access to information and records that FDA has the authority to inspect under section 704(a) of the FD&C Act.”

Congers, NY, United StatesIssued Nov 13, 2026Posted Nov 24, 2026No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
6 findings · 5 issue types
Response due
Not stated in the letter
FDA asks for
8 actions
Named as possible actions
Seizure, injunction, refusal of admission
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01OtherThe firm delayed, denied, limited, or refused FDA inspection by failing to provide requested records, removing and modifying records, and making key personnel unavailable.
Your firm delayed, denied, limited, or refused the FDA inspection based on certain actions in relation to access to information and records that FDA has the authority to inspect under section 704(a) of the FD&C Act.
02Quality unit & oversight · 21 CFR 211.192The quality control unit failed to review and approve all production and control records before batch release, including unprocessed chromatographic and UV-vis data.
Your firm's quality control unit failed to review and approve all drug product production and control records to determine compliance with all established, approved written procedures before a batch is released or distributed (21 CFR 211.192).
03Facilities & equipment · 21 CFR 211.42(d)The firm failed to perform penicillin operations in facilities separate from other drug products, with evidence of material flow between buildings.
Your firm failed to perform operations related to the manufacture, processing, and packing of penicillin in facilities separate from those used for other drug products for human use (21 CFR 211.42(d)).
04Laboratory controls & testing · 21 CFR 211.176The firm failed to test non-penicillin drug products for penicillin when a reasonable possibility of cross-contamination existed.
Your firm failed to test non-penicillin drug products for the presence of penicillin when a reasonable possibility existed that the non-penicillin drug product had been exposed to cross-contamination with penicillin (21 CFR 211.176).
05Quality unit & oversight · 21 CFR 211.22The quality control unit failed to ensure drug products are manufactured in compliance with CGMP and meet specifications, including lack of packaging batch records, unvalidated methods, inadequate release testing, and unsubstantiated expiration dates.
Your firm's quality control unit failed to exercise its responsibility to ensure drug products are manufactured in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).
06Registration, listing & premarketThe firm manufactured and distributed unapproved new drugs because the facility was not listed in the approved applications.
Because the drug products are being manufactured at a facility not approved under their respective drug applications, they are not covered by the approved applications.

Additional FDA passages

1 extracted findings

Selected FDA passages, not the complete letter.

01

You failed to adequately document and investigate the reasons for not processing all electronic data points. For example,

What FDA requested

  • A comprehensive investigation into unprocessed data related to both chromatographic and UV-vis testing, including details to support statements that data is not attributed to a specific product sample.
  • A comprehensive investigation into the extent of inaccuracies in data records and reporting, including evaluation of unprocessed data that could be related to OOS results, with protocol, methodology, summary of laboratory systems, interviews, assessment of data integrity deficiencies, and retrospective evaluation.
  • A current risk assessment of the potential effects of the observed failures on drug quality, including risks to patients and ongoing operations.
  • A management strategy with a detailed corrective action plan, root cause description, interim measures, long-term measures, commitment to annual audits for at least two years, and status report.
  • A table listing all OOS results relating to drug products distributed in the U.S. market, including date, batch code, description, location, root cause, confirmation status, and disposition.
  • A comprehensive, independent assessment by a qualified third party evaluating future measures to prevent beta-lactam cross-contamination in both buildings.
  • A program for future monitoring of beta-lactam residue throughout both buildings, including air intake, exhaust, vacuum systems, HVAC filters, entry/egress points, personnel flow, gowning, material storage, decontamination, and testing.
  • An immediate plan to perform environmental sampling for beta-lactam cross-contamination, including frequency, locations, and validated methodologies, plus any testing performed to date, and timelines for assessment and CAPA effectiveness evaluation, and floor plans for beta-lactam areas with material and personnel flow and permitted product types per building.

FDA Warning Letter

135 paragraphs · 12 sections

Text as published on FDA.gov, retrieved Nov 24, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedNovember 13, 2026
Reference320-27-23
AddressedMr. Jack Goldenberg

1Introduction

1 paragraph

This warning letter advises you of significant violations observed during a U.S. Food and Drug Administration (FDA) inspection of your facility and provides you an opportunity to address them. Promptly address any violations described in this letter, and as part of that effort ensure that you allocate appropriate resources to fully address them and prevent their recurrence. This is not intended to be an all-inclusive list of the violations that may exist at your facility. It is your responsibility to ensure that your firm complies with all requirements of federal law, including FDA regulations. Failure to adequately address any violations may result in regulatory or legal action without further notice including, without limitation, seizure and injunction.

2FDA Inspection

9 paragraphs

Violations were observed and documented during an inspection of your drug manufacturing facility, Chartwell Pharmaceuticals Congers, LLC, FDA Establishment Identifier (FEI) 3008897678, at 77 Brenner Drive and 150 Wells Avenue, Congers, NY 10920, from October 6 to November 18, 2025. This inspection was conducted under FDA’s statutory authority and public health responsibilities to protect the public from unsafe, ineffective, and poor-quality drugs.

During the inspection our FDA investigators documented that your firm delayed, denied, limited, and/or refused to permit an FDA inspection. Under section 501(j) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) 21 U.S.C. 351(j), your drugs are adulterated in that they have been manufactured, processed, packed, or held in an establishment where the owner or operator has delayed, denied, limited, and/or refused to permit inspection.

In addition, this warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding drugs do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act, 21 U.S.C. 351(a)(2)(B).

The introduction or delivery for introduction into interstate commerce of an adulterated drug is a prohibited act under section 301(a) of the FD&C Act, 21 U.S.C. 331(a). Additionally, refusal to permit access to any record as required by section 704(a) is a prohibited act under section 301(e) of the FD&C Act, 21 U.S.C. 331(e).

Furthermore, your firm manufactures and distributes unapproved new drugs in violation of section 505(a) of the FD&C Act, 21 U.S.C. 355(a). The introduction or delivery for introduction into interstate commerce of these products, including but not limited to the list below, violates sections 505(a) and 301(d) of the FD&C Act, 21 U.S.C. 355(a) and 331(d).

Benzonatate Capsules, USP 100 mg and 200 mg; Budesonide Inhalation Suspension 0.25 mg/2mL and 0.5 mg/2mL; Dapsone Tablets, USP 25 mg and 100 mg; Fluvoxamine Maleate Tablets, USP 25 mg, 50 mg, and 100 mg; Imatinib Mesylate Tablets 100 mg and 400 mg; Meclizine Hydrochloride Tablets, USP 12.5 mg, 25 mg, and 50 mg; Minocycline Hydrochloride Tablets 50 mg, 75 mg, and 100 mg; Moexipril Hydrochloride Tablets, USP 7.5 mg and 15 mg; Prednisolone Sodium Phosphate Oral Solution 5 mg/5 mL; Repaglinide Tablets USP 0.5 mg, 1 mg, and 2 mg; Rivastigmine Tartrate Capsules, USP 1.5 mg, 3 mg, 4.5 mg, and 6 mg; Sucralfate Tablets, USP 1 g; Thioridazine Hydrochloride Tablets, USP 10 mg, 50 mg and 100 mg; Doxycycline Hyclate Tablets, USP 75 mg and 150 mg; Pioglitazone Hydrochloride Tablets, USP 15 mg, 30 mg, and 45 mg; Anagrelide Capsules, USP 0.5 mg and 1 mg; Sildenafil Tablets, USP 20 mg, Cetirizine Hydrochloride Oral Solution, USP 1 mg/mL; Oxybutynin Chloride Oral Solution, USP 5 mg/5 mL; and Hydroxyzine Hydrochloride Oral Solution, USP 10 mg/5 mL.

The unapproved new drug violations for these products are described in more detail below.

We reviewed your December 10, 2025, response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.

3Violations of the Federal Food, Drug, and Cosmetic Act

1 paragraph

The following are violations identified during our inspection. As a reminder, this is not an all-inclusive list of violations at your facility.

4Violations of 501(j)

9 paragraphs

Your firm delayed, denied, limited, or refused the FDA inspection based on certain actions in relation to access to information and records that FDA has the authority to inspect under section 704(a) of the FD&C Act. Examples of such instances were:

Failure to Provide Records

On October 6, 2025, and multiple times later during the inspection, our investigators requested your 2023 to 2025 logs for production, packaging, rejects, and returns of your drug products. However, you did not provide these records as requested by the FDA investigators.

On October 6, 2025, our investigators also requested distribution information for your drug products. Two weeks later, on October 23, 2025, you provided packing lists that indicated you only distributed approximately ten drug products (for example, (b)(4) Tablets USP (b)(4) mg1; (b)(4) Capsules USP (b)(4) mg; (b)(4) Suspension USP (b)(4) mg/(b)(4) mL; (b)(4) Suspension USP (b)(4) mg/(b)(4) mL; Griseofulvin Oral Suspension USP 125 mg/5 mL; Griseofulvin Tablets USP 125 mg, 250 mg and 500 mg; (b)(4) USP (b)(4) mg, (b)(4) mg; (b)(4) mg/mL; (b)(4) Solution USP (b)(4) mg/(b)(4) mL2; Hyoscyamine Sulfate Oral Drops USP 0.125 mg/mL; and (b)(4) Solution USP (b)(4) mg/(b)(4) mL2) in the last three years. While you stated to our investigators that this information was accurate, on October 24, 2025, our investigators asked the Head of Warehouse to show the finished product lot inventory log stored on a computer. After multiple requests, investigators observed and were provided with an electronic log that contained conflicting information from the packing lists previously provided, including information about the distribution of additional drug products, some of which were unapproved new drugs. On October 24, 2025 and November 6, 2025, our investigators again requested the official shipping records for all drugs distributed, and you did not provide these records during the inspection or later in your response.

Removal and Modification of Records

On October 29, 2025, our investigators located additional, hard copy distribution records in a warehouse cabinet and brought them to the conference room for review. Contrary to our investigators' request to keep these records secured in the conference room, your personnel removed them from the room. After multiple requests, the records were returned on November 6, 2025; however, a comparison of the returned documents with photographs of the original documents taken by our investigators on October 29, 2025, revealed discrepancies. For example, the packing lists and bills of lading that you provided on November 6, 2025, were modified to show distribution of fewer drug product batches compared to the records our investigators originally located on October 29, 2025. In addition, the records returned on November 6, 2025, were incomplete as the shipping entries for certain drug products (for example, (b)(4) Capsules, Sildenafil Tablets, and (b)(4) Tablets) were removed. Of note, a comparison of the original documents FDA located and photographed on October 29, 2025, to the documents that you returned on November 6, 2025, indicate that the modifications made to the returned documents relate to some of the unapproved new drugs discussed in the “Unapproved New Drug Violations” section of this letter.

Unavailability of Key Personnel for Interview

On October 6, 2025, our investigators interviewed a laboratory analyst about the dissolution and assay analyses of a (b)(4)-month stability sample of (b)(4) Capsules, USP (b)(4) mg, batch (b)(4), as well as the impurity analysis of a 36-month stability sample of (b)(4) Capsules, USP (b)(4) mg, batch (b)(4). The purpose of the interview was to gather information on the failure to process all injections during the analysis and the failure to document sample and standard weights in the associated laboratory notebook. When our investigators sought to continue the interview on October 9, 2025, you indicated the analyst was absent due to illness. The analyst did not return to the facility for the remaining weeks of the inspection, and you did not provide adequate information to address our investigators’ questions about these analyses.

Because an owner, operator, or agent delayed, denied, limited, or refused an inspection, the drugs are deemed adulterated under section 501(j) of the FD&C Act. See FDA’s guidance document Circumstances that Constitute Delaying, Denying, Limiting, or Refusing a Drug or Device Inspection at https://www.fda.gov/media/86328/download.

5CGMP Violations

22 paragraphs

1. Your firm’s quality control unit failed to review and approve all drug product production and control records to determine compliance with all established, approved written procedures before a batch is released or distributed (21 CFR 211.192).

Chromatographic Electronic Data Not Processed

Electronic data for chromatographic analyses conducted from 2024 to 2025 were not evaluated and processed (i.e., results were not generated for all injections performed) following written procedures. The inspection documented that numerous chromatographic injections of standards and samples for multiple drug products (for example, (b)(4) Capsules, (b)(4), and (b)(4) Tablets3, among others) remained unprocessed for months. For different drug products, the percentage of unprocessed injections ranged from 9% to 77%. During the inspection, your Quality Control (QC) Director acknowledged that he was not aware of the unprocessed data. When analytical data is not processed, it cannot be evaluated as part of the stability studies or finished drug product testing prior to release.

You failed to adequately document and investigate the reasons for not processing all electronic data points. For example,

A. On October 6, 2025, we found unprocessed data for the impurity analysis of a 36-month stability sample of (b)(4) Capsules, USP (b)(4) mg, batch (b)(4), performed on September 22, 2025. Our investigators found unofficial calculation sheets for this analysis containing different sample and standard weights that showed out-of-specification (OOS) results of (b)(4)% and (b)(4)% for Impurity (b)(4) (specification NMT (b)(4)%); and of (b)(4)% and (b)(4)% for Any Individual Unspecified Impurity (specification NMT (b)(4)%). Approximately one month after the analysis, the chromatographic data remained unprocessed, and the calculated OOS results had not been reported or investigated. Multiple packaging configurations of the same bulk batch, (b)(4), were distributed and remain in the U.S. market.

B. We also found unprocessed data for the dissolution and assay analyses of a (b)(4)-month stability sample of (b)(4) Capsules, USP (b)(4) mg, batch (b)(4), performed on August 4-5, 2025. The laboratory notebook lacked the information for the sample and standard weights needed to perform the calculations to process the chromatographic data. The analyst could not explain why this data was missing. Our investigators also found unofficial, rough calculations with the corresponding stability summary. You did not open a laboratory investigation regarding the missing data for sample and standard weights.

C. You did not report your analytical testing results within appropriate timeframes to ensure any unexpected results are investigated in a timely manner. For example, test data for related substances analyses performed as part of accelerated stability studies for (b)(4) mg (b)(4), batches (b)(4), were acquired on August 28, 2024; however, the data remained unprocessed and unreported at the time of the inspection, more than one year later. You did not open a laboratory investigation into your failure to process this data.

D. The data for content uniformity analysis of (b)(4) mg (b)(4), validation batch (b)(4), initiated on August 21, 2024, was not processed. You documented in the laboratory notebook that the average tablet weight exceeded the (b)(4) limit established for loss of mass testing in the validation protocol. However, you did not open a deviation protocol or a laboratory investigation to determine the root cause of this failure. Instead, on August 22, 2024, you prepared new samples of tablets (b)(4), performed the analysis with the new sample preparations and the same standards, and reported satisfactory results.

In your response, you commit to conducting an independent third-party assessment of the laboratory data and your procedures. You also state, in your correspondence to the agency, that your preliminary review of approximately 665 chromatographic data points associated with single injections are related to standards, diluent, system suitability and resolution solutions, and you have not identified a case where a single injection can be attributed to a specific product sample.

Your response is inadequate in that you do not include detailed information of your assessment of the 665 chromatographic data points. You also state that you have not encountered a case where a not-processed injection in a sample set resulted in an OOS. This statement is not aligned with our observations during the inspection, and you do not address them in your response.

Ultraviolet-visible (UV-vis) Spectroscopy Electronic Data Not Processed

Electronic data for ultraviolet-visible (UV-vis) spectroscopy analyses conducted from 2022 to 2025 were not evaluated and processed following appropriate written procedures. Our investigators identified numerous methods in draft status, samples lacking status information, and others left in an “in progress” status. Your personnel explained during the inspection that the status of the sample will show as “in progress” when results are neither processed after reading the UV absorbance nor documented in the laboratory notebook. The inspection also documented that the initial data was not documented in the corresponding laboratory notebooks, and samples were reanalyzed without a laboratory investigation.

For example, your 12-month long-term stability sample of (b)(4) Tablets (b)(4) mg, batch (b)(4), was analyzed for dissolution three times on March 19, 2025, and showed UV-vis scans with both “in progress” and “complete” statuses. Despite multiple UV-vis scans for this sample, the laboratory notebook only contained documentation for one analysis. You did not open a laboratory investigation to document why you did not process the data from all analyses and to justify the subsequent reanalysis.

In your response, you commit to conducting an independent third-party assessment of the laboratory data and your procedures. You also state, in your correspondence to the agency, that from the approximately 147 “in progress” tasks associated with your UV-vis analyses, 95 are not related to product-specific samples, 22 are related to research and development (R&D) activities, and 30 related to QC activities. You also state that from the UV-vis data reviewed, you did not encounter any OOS results.

You did not provide sufficient data to support your statement that this data does not pertain to specific product samples during the inspection or in your response.

Your handling of laboratory data demonstrates a systematic failure to maintain complete and accurate laboratory control mechanisms under 21 CFR 211.160(a), which represents serious data integrity deficiencies that undermine the reliability of your analytical testing and batch release decisions.

Your quality system does not adequately ensure the accuracy and integrity of data to support the safety, effectiveness, and quality of the drugs you manufacture. See FDA’s guidance document Data Integrity and Compliance With Drug CGMP: Questions and Answers for guidance on establishing and following CGMP compliant data integrity practices at https://www.fda.gov/media/119267/download.

We acknowledge that you are using an independent third-party consultant to audit your operations and assist in meeting FDA requirements. We strongly recommend that you retain an independent third-party qualified consultant to assist in your remediation. In response to this letter, provide:

A comprehensive investigation into unprocessed data related to both chromatographic and UV-vis testing. Include details to support your statements that data is not attributed to a specific product sample.

A comprehensive investigation into the extent of the inaccuracies in data records and reporting, including evaluation of unprocessed data that could be related to OOS results. Your investigation should include:o A detailed investigation protocol and methodology; a summary of all laboratory systems to be covered by the assessment; and a justification for any part of your operation that you propose to exclude.o Interviews of current and former employees to identify the nature, scope, and root cause of data inaccuracies. We recommend that these interviews be conducted by an independent qualified third party.o An assessment of the extent of data integrity deficiencies at your facility. Identify omissions, alterations, deletions, record destruction, non-contemporaneous record completion, and other deficiencies. Describe all parts of your facility’s operations in which you discovered data integrity lapses.o A comprehensive retrospective evaluation of the nature of the testing data integrity deficiencies. We recommend that an independent qualified third party with specific expertise in the area where potential breaches were identified should evaluate all data integrity lapses.

A current risk assessment of the potential effects of the observed failures on the quality of your drugs. Your assessment should include analyses of the risks to patients caused by the release of drugs affected by a lapse of data integrity and analyses of the risks posed by ongoing operations.

A management strategy for your firm that includes the details of your global corrective action and preventive action (CAPA) plan. Your strategy should include:o A detailed corrective action plan that describes how you intend to ensure the reliability and completeness of all the data you generate including analytical data, manufacturing records, and all data submitted to FDA.o A comprehensive description of the root causes of your data integrity lapses including evidence that the scope and depth of the current action plan is commensurate with the findings of the investigation and risk assessment. Indicate whether individuals responsible for data integrity lapses remain able to influence CGMP-related data or drug application data at your firm.o Interim measures describing the actions you have taken or will take to protect patients and to ensure the quality of your drugs, such as notifying your customers, recalling product, conducting additional testing, adding lots to your stability programs to assure stability, drug application actions, and enhanced complaint monitoring. o Long-term measures describing any remediation efforts and enhancements to procedures, processes, methods, controls, systems, management oversight, and human resources (for example, training, staffing improvements) designed to ensure the integrity of your company’s data.o A commitment to have an independent qualified consultant conduct extensive annual audits, for at least two years, to assist in evaluating CAPA effectiveness after you have executed your data integrity remediation protocol.o A status report for any of the above activities already underway or completed.

6Test Results Out-of-Specification

9 paragraphs

For more information about handling failing, out-of-specification, out-of-trend, or other unexpected results and documentation of your investigations, see FDA’s guidance document Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production at https://www.fda.gov/media/158416/download.

In response to this letter, provide a table listing all OOS results relating to drug products distributed in the U.S. market, including those identified from unprocessed analysis, rough calculations/notes, and unofficial logbooks, including the following information:

Date OOS result occurred

Batch code(s)

Description of OOS result

Location of OOS document (rough calculations/notes and unofficial logbooks)

Description of root cause

Whether the OOS result was confirmed or invalidated as a laboratory error

Disposition of batch(es)

72. Your firm failed to perform operations related to the manufacture, processing, and packing of penicillin in facilities separate from those used for other drug products for human use (21 CFR 211.42(d)).

47 paragraphs

Your operations are conducted in two separate buildings: the main non-beta-lactam facility at 77 Brenner Drive, and the beta-lactam facility at 150 Wells Avenue. The current inspection revealed failures in material and documentation control that compromise the separation of these distinct operations. This is a repeat observation as deficiencies related to beta-lactam cross-contamination controls were previously documented during your December 2024 inspection.

For example, during the inspection, our investigators found a logbook in the sampling booth of the non-beta-lactam facility (77 Brenner Drive) documenting the sampling and receipt of (b)(4) active pharmaceutical ingredient (API), a penicillin beta-lactam. The entries in this logbook were dated between March and April 2025; however, the logbook was found in the non-beta-lactam facility during the inspection, six months later. This logbook had missing pages with no explanation. There were no other records (for example, logbooks) in the beta-lactam facility (150 Wells Avenue) documenting the receipt and sampling of (b)(4) API at that building.

The presence of material, such as a logbook, that should only be located in the beta-lactam building, in the non-beta-lactam building indicates that material continues to flow between the buildings, and you do not have complete separation of your beta-lactam operations. This is especially concerning because the previous inspection documented a similar deficiency where manufacturing equipment used to produce beta-lactam drugs was moved between the two buildings and subsequently used to manufacture non-beta-lactam drugs without sufficient evidence that it was first adequately cleaned and decontaminated.

In your response, you attribute the misplaced logbook to an employee inadvertently taking the logbook home and returning it to the incorrect building (77 Brenner Drive). You also provide a report for an extended swab sampling study for (b)(4) residues in the non-beta-lactam building.

Your response is inadequate because it fails to address the fundamental deficiencies that resulted in the failure to meet required separation of operations. Specifically, the uncontrolled movement of a production logbook removed from the facility, taken to an employee’s home, and returned to the incorrect building. You also lack provisions for a routine penicillin beta-lactam monitoring program to include routine sampling in the non-beta-lactam areas/buildings.

Contamination of non-beta-lactam drugs with beta-lactam drugs presents great risk to patient safety, including potential anaphylaxis and death. No safe level of penicillin contamination has been determined to be a tolerable risk. Severe allergenic responses can occur in susceptible patients exposed to extremely low levels of penicillin and other beta-lactams.

A vigilant, ongoing environmental monitoring program for beta-lactam residues is essential to detect and respond to potential product contamination hazards in your manufacturing environment in a timely manner.

For more information, see FDA’s guidance document, Non-Penicillin Beta-Lactam Drugs: A CGMP Framework for Preventing Cross-Contamination, at https://www.fda.gov/media/79971/download.

In response to this letter, provide:

A comprehensive, independent assessment by a qualified third party evaluating future measures to prevent risk of beta-lactam cross-contamination in both buildings (non-beta-lactam and penicillin beta-lactam). The assessment should identify potential routes of beta-lactam contamination, evaluate the instances of potential cross-contamination identified during the inspection (for example, the presence of material, such as a logbook, that should only be in the beta-lactam building), as well as controls for personnel activities.

A program for future monitoring of beta-lactam residue throughout both buildings, as applicable based on the assessment report. The monitoring program should include, but not be limited to, air intake and exhaust, vacuum systems, HVAC filter locations, entry points, egress points, people/material/equipment flow, personnel gowning, material storage, decontamination practices, monitoring containment, and testing.

Your immediate plan to perform environmental sampling of your facility for beta-lactam cross-contamination, including frequency and sampling locations using robust and validated methodologies. In addition, provide any testing performed to date.

Timelines for the independent assessment and how you intend to evaluate the effectiveness of your CAPA.

Floor plans for each area where beta-lactam operations occur, clearly illustrating the flow of materials and personnel. Also describe which specific product types can be sampled, produced, or otherwise manipulated in each of the buildings, as well as which product types are not permitted.

3. Your firm failed to test non-penicillin drug products for the presence of penicillin when a reasonable possibility existed that the non-penicillin drug product had been exposed to cross-contamination with penicillin (21 CFR 211.176).

You lacked a testing program for non-beta-lactam drug products manufactured at your facility for the presence of beta-lactams despite previous findings of potential beta-lactam cross-contamination at your firm. The example cited under item 2 of this letter further demonstrates that your beta-lactam operations are still not completely separated from non-beta-lactam operations.

In response to this letter, provide a commitment to test reserve samples of all non-beta-lactam products within expiry for the presence of beta-lactam to a limit of detection (LOD) of 0.2 parts per billion (ppb). Please see FDA’s published analytical method which has a LOD of 0.2 ppb at https://www.ncbi.nlm.nih.gov/pubmed/29766324. If such testing reveals the presence of beta-lactams above this limit, take rapid corrective actions, such as notifying customers and initiating recalls, as appropriate.

Additionally, provide a commitment to test reserve samples of all (b)(4) drug products purchased by the U.S. government, even if expired, for the presence of beta-lactam residue using FDA’s analytical method referenced above or a validated method with a LOD that is equivalent to or better than 0.2 ppb. Notify this office if any samples are found above this limit. In addition, provide your plan and procedures, including test methods, for conducting testing of non-beta-lactam drugs for beta-lactam residues with a LOD of 0.2 ppb prior to release.

4. Your firm’s quality control unit failed to exercise its responsibility to ensure drug products are manufactured in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).

Quality Unit (QU) Failure to Follow Approved Procedures

During the inspection, you acknowledged that you did not issue packaging batch records for Folic Acid Tablets, USP 1 mg in packaging configurations 770631C to 770631J and for (b)(4) Capsules, USP (b)(4) mg in packaging configurations (b)(4) and (b)(4), as required by your written procedures. Our inspection also documented at least five additional instances where a packaging record was not issued for (b)(4) Capsules batches distributed in the U.S. market.

Your response is inadequate because you do not address the lack of packaging batch records for distributed drug products.

Use of Unvalidated Analytical Method

You distributed two batches of (b)(4) mg in different packaging configurations ((b)(4)) that were analyzed with an unvalidated analytical method for related compounds and without final approval from your QU. You used an analytical method validated for the (b)(4) mg and (b)(4) mg strengths to conduct release testing on the (b)(4) mg strength of (b)(4). At the time of the inspection, the method revision to include the (b)(4) mg and (b)(4) mg strengths was still in draft form and had not been approved. Using an unvalidated method provides no assurance that the test results are accurate.

In your response, you state that you completed the method validation, processed the samples for batches (b)(4) using the now validated method, and approved the results.

Your response is inadequate because it does not address the distribution of these batches analyzed using an unvalidated method. You also fail to include the method validation report and the results of the reanalysis of those samples with the validated method. In addition, you do not address how you will ensure that all your analytical methods are validated for their intended use and how you will conduct appropriate quality review.

In response to this letter, provide documentation to demonstrate that all batches of (b)(4) mg have been reanalyzed using the validated method to ensure they meet the quality attributes that they purport to possess.

Distribution of Drugs Lacking Adequate Release Testing

You distributed two batches of (b)(4) Tablets4, ((b)(4) mg, batch (b)(4) and (b)(4) mg, batch (b)(4)) without adequate release testing for assay and (b)(4) uniformity for the (b)(4), batch (b)(4), used in the manufacturing of the referenced tablet batches, as required by 21 CFR 211.165(a). The assay testing was performed with a UV-vis spectroscopy method, instead of the ultra-performance liquid chromatography (UPLC) method, as required by your test procedures.

In addition, your firm’s batch records for these batches were also deficient. For example, the manufacturing batch records for two related batches were incomplete, in that they were missing data and calculations for critical manufacturing stages, including compression, yield calculation, and (b)(4). Furthermore, your firm was unable to provide the packaging batch records for the two batches that were shipped in the U.S. market (batches (b)(4)). Without these records, you cannot demonstrate that the batches were packaged correctly and met all quality attributes.

In your response, you acknowledge the documentation deficiencies and conclude there is no impact on product quality. You also state that (b)(4) Tablets batches were sent to the distributor as samples and were not distributed to the U.S. market.

Your response is inadequate because you do not include the testing results from an appropriate test method, and you do not address the documentation deficiencies. In addition, you do not explain your rationale for shipping these batches as samples, and do not provide evidence that the product was not distributed in the U.S. market.

Distribution of Drug Products with Unsubstantiated Expiration Dates

You distributed drug products that did not bear an expiration date determined by appropriate stability testing, as required under 21 CFR 211.137 and 211.166. In addition, batches were distributed without final QU approval.

For example,

A. You packaged (b)(4) Capsules, bulk batch (b)(4), in three different packaging configurations ((b)(4)). Bulk batch (b)(4) was manufactured in July 2022 and assigned an expiration date of (b)(4) despite the (b)(4) approved expiration date of (b)(4). Batch (b)(4) was released on August 18, 2023, and batch (b)(4) was released on August 22, 2023. You also distributed a third packaging configuration, batch (b)(4), without a packaging batch record. Refer to item 1A of this letter for the calculated OOS result that was not adequately investigated and reported during the analysis of a stability sample of this batch.

B. (b)(4) Capsules USP (b)(4) mg, batch (b)(4), was shipped with an expiration date of (b)(4) despite only having six months of long-term stability data available. This batch also lacked QU release approval. Other examples include (b)(4) Tablets, USP (b)(4) mg, batch (b)(4), which was assigned an expiration date of (b)(4) and distributed despite only having six months of long-term stability data available and an un-signed QU release; and Sildenafil Tablets, USP 20 mg, batch 771553A, which was assigned an expiration date of (b)(4) and distributed despite only having 12 months of long-term stability data available and an un-signed QU release5.

C. You distributed two packaging configurations of (b)(4) mg (batches (b)(4)) with an expiration date of (b)(4) and without documentation of release by QU. This expiration date exceeds the approved (b)(4) expiration period for this product and was assigned without adequate stability data to support the extension.

D. Folic Acid Tablets, USP 1 mg, batch 770631J, was distributed on July 24, 2025 with an expiration date of (b)(4). However, records showed the bulk batch was manufactured on July 15, 2019, over six years prior. Based on the approved (b)(4) expiration period for this product, the expiration date should have been no later than (b)(4). In addition, your records indicated that a packaging batch record was only issued for batch 770631A, and you could not provide a corresponding packaging record for the distributed batch 770631J.

In your response, you state that you have stability data to extend the expiration dates assigned.

Your response is inadequate because it does not include the data to support the extended expiration dates, and this data has not previously been provided to the agency for evaluation. Furthermore, your response does not address the lack of packaging batch records and lack of QU approval for shipped drug products currently in the U.S. market.

In response to this letter, provide the following information for all your application drug products:

• Product name• Product dosage• Application/supplement number• Application/supplement approval date• Approved expiration date• Available stability data, and• Expiration date extension submission to the agency, if applicable.

For more information about stability testing, see FDA’s guidance document Q1A(R2) Stability Testing of New Drug Substance and Products located at https://www.fda.gov/media/71707/download.

Your firm’s quality systems are inadequate. See FDA’s guidance document ICH Q10 Pharmaceutical Quality System, as well as Quality Systems Approach to Pharmaceutical CGMP Regulations, for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71553/download and https://www.fda.gov/media/71023/download respectively.

In response to this letter, provide the following:

A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to the following:o A determination of whether procedures used by your firm are robust and appropriateo Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices.o A complete and final review of each batch and its related information before the QU disposition decision, including batches distributed without a packaging batch record.o Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products.o Detailed information about batches distributed without packaging batch records including packaging configuration, release documentation, unsubstantiated expiration dates, customers, and any necessary market action taken.

8Unapproved New Drug Violations

5 paragraphs

The following drug products are approved under the respective drug applications:

• Benzonatate Capsules, USP 100 mg and 200 mg (ANDA 040682)• Budesonide Inhalation Suspension 0.25 mg/2mL and 0.5 mg/2mL (ANDA 078202)• Dapsone Tablets, USP 25 mg and 100 mg (ANDA 204074)• Fluvoxamine Maleate Tablets, USP 25 mg, 50 mg, and 100 mg (ANDA 075900)• Imatinib Mesylate Tablets 100 mg and 400 mg (ANDA 208429)• Meclizine Hydrochloride Tablets, USP 12.5 mg, 25 mg, and 50 mg (ANDA 203003)• Minocycline Hydrochloride Tablets 50 mg, 75 mg, and 100 mg (ANDA 065436)• Moexipril Hydrochloride Tablets, USP 7.5 mg and 15 mg (ANDA 077536)• Prednisolone Sodium Phosphate Oral Solution 5 mg/5 mL (ANDA 075988)• Repaglinide Tablets USP 0.5 mg, 1 mg, and 2 mg (ANDA 078555)• Rivastigmine Tartrate Capsules, USP 1.5 mg, 3 mg, 4.5 mg, and 6 mg (ANDA 207797)• Sucralfate Tablets, USP 1 g (ANDA 074415)• Thioridazine Hydrochloride Tablets, USP 10 mg (ANDA 088131)• Thioridazine Hydrochloride Tablets, USP 50 mg (ANDA 088134)• Thioridazine Hydrochloride Tablets, USP 100 mg (ANDA 088135)• Doxycycline Hyclate Tablets, USP 75 mg and 150 mg (NDA 205931)• Pioglitazone Hydrochloride Tablets, USP 15 mg, 30 mg, 45 mg (ANDAs 078383 and 076798)• Anagrelide Capsules, USP 0.5 mg and 1 mg (ANDA 076683)• Sildenafil Tablets, USP 20 mg (ANDA 202598)• Cetirizine Hydrochloride Oral Solution, USP 1 mg/mL (ANDA 078876)• Oxybutynin Chloride Oral Solution, USP 5 mg/5 mL (ANDA 075039)• Hydroxyzine Hydrochloride Oral Solution, USP 10 mg/5 mL (ANDA 201674)

However, the Chartwell Pharmaceutical Congers facility (FEI 3008897678) is not listed in the respective drug applications as an approved manufacturing site for these drug products. Our records indicate that no supplemental applications have been approved to include Chartwell Pharmaceutical Congers as a drug product manufacturing facility in the above-mentioned NDA and ANDAs.

Changing the finished dosage form manufacturing facility to the Chartwell Pharmaceuticals Congers facility for these products is considered a major manufacturing change requiring submission—and FDA approval of—a supplemental application. See 21 U.S.C. § 356a(c)(1) and 21 CFR 314.70(b)(1). Because the drug products are being manufactured at a facility not approved under their respective drug applications, they are not covered by the approved applications. Your products listed above are not generally recognized as safe and effective (GRASE) for their above referenced uses and, therefore, these products are “new drugs” under section 201(p) of the FD&C Act, 21 U.S.C. 321(p). Subject to certain exceptions not applicable here, new drugs may not be legally introduced or delivered for introduction into interstate commerce without an approved application from FDA in effect, as described in sections 301(d) and 505(a) of the FD&C Act, 21 U.S.C. 331(d) and 355(a). There are no FDA-approved applications in effect for these products manufactured at the Chartwell Pharmaceuticals Congers facility. Accordingly, these products are unapproved new drugs marketed in violation of sections 301(d) and 505(a) of the FD&C Act, 21 U.S.C. 331(d) and 355(a).

The above-listed drug products are not an all-inclusive list of products associated with this violation. It is your responsibility to review the totality of your inventory to ensure that your firm complies with all requirements of federal law, including FDA regulations.

9Repeat Observations at Facility

1 paragraph

In previous inspections, dated May 31, 2024 and December 19, 2024, FDA cited similar CGMP observations. You proposed specific remediation for these observations in your response. Repeated failures demonstrate that executive management oversight and control over the manufacture of drugs is inadequate.

10CGMP Consultant Recommended

2 paragraphs

Based upon the nature of the violations we identified at your firm, you should engage a qualified consultant as set forth in 21 CFR 211.34 to assist your firm in meeting CGMP requirements.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

11Additional Beta-Lactam Cross-Contamination Concerns

2 paragraphs

Our investigators also found commingled empty bottles of beta-lactam and non-beta-lactam drug products in the same garbage bag located in a dumpster behind the non-beta-lactam building. The presence of mixed beta-lactam and non-beta-lactam product containers could also indicate inadequate segregation of materials and raises concerns about potential cross-contamination of non-beta-lactam drugs with beta-lactam residues. This is particularly significant given the allergenic potential of beta-lactam antibiotics and the risk to sensitized individuals. The beta-lactam drug bottles found in the dumpster were (b)(4) Tablets, USP ((b)(4) mg/(b)(4) mg, and labeled as manufactured in (b)(4)), (b)(4) Tablets, USP ((b)(4) mg/(b)(4) mg, and labeled as manufactured in (b)(4)) and (b)(4) Capsules, USP (b)(4) mg. All empty bottles bore Chartwell Rx labels.

In response to this letter, provide additional information about the manufacturing, distribution, and/or disposal of these beta-lactam products. Please include any new drug application (NDA) and abbreviated new drug application (ANDA) numbers associated with these beta-lactam products.

12Conclusion

5 paragraphs

As previously stated, you are responsible for investigating and determining the root causes of any violations and implementing corrective and preventive measures to ensure future and sustained compliance so that these violations and any others do not occur.

Other federal agencies may take your compliance history into account when considering the award of contracts. Failure to address any violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

Send your written response to CDER-OC-OMQ-Communications@fda.hhs.gov within 15 business days of receipt of this letter6. If you have information that you believe demonstrates that your products are not in violation of the FD&C Act and FDA regulations, include that information for our consideration. Identify your response with FEI 3008897678 and ATTN: Vilmary Negrón Rodríguez in the subject line of the email.

We also request that you email CDER-OC-OMQ-Communications@fda.hhs.gov within 5 days of receipt of this letter to schedule a regulatory meeting. Identify your response with FEI 3008897678 and ATTN: Temeka Moore.

Please note FDA posts warning letters on www.FDA.gov.

Sincerely,/S/

Jill P. Furman, JDDirectorOffice of ComplianceCenter for Drug Evaluation and ResearchU.S. Food and Drug Administration__________________________

1 (b)(4).

2 (b)(4).

3 (b)(4).

4 (b)(4).

5 (b)(4).

6 Under program enhancements for the Generic Drug User Fee Amendments (GDUFA) reauthorization for fiscal years (FYs) 2023-2027, also known as the GDUFA III Commitment Letter, your facility may be eligible for a Post-Warning Letter Meeting to obtain preliminary feedback from FDA on the adequacy and completeness of your corrective action plans.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 13, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

21 CFR 211.176Penicillin contamination2letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 211.176 →
020210202212023020240202512026
21 CFR 314.70Supplements and other changes to an approved NDA1letters cite it
1 letter issued this year vs 0 by the same date last yearAbout 21 CFR 314.70 →
020210202202023020240202512026
21 CFR 211.34Consultants9letters cite it
2 letters issued this year vs 0 by the same date last yearAbout 21 CFR 211.34 →

Also cited: 21 CFR 210

Issue types

OtherAI-assigned issue type141letters1finding here
26 letters issued this year vs 35 by the same date last year · -26%

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
Congers, NY, United States
Letter posted date
Nov 24, 2026
Letter issue date
Nov 13, 2026
Addressed to
Managing Member
Inspection dates
Oct 6, 2025 to Nov 18, 2025
Response window
Not verified in this snapshot. Consult the original letter.
Record length
6,407 words · 130 recorded redactions
Published status
No published close-out
FDA reference
320-27-23
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 24, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,712 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.