Central Admixture Pharmacy Services, Inc.
6 extracted findings · 6 model-assigned issue types
FDA source excerpt, selected passage
Production areas and equipment were visibly dirty.
Findings and supporting evidence
Model-assisted readings, not an exhaustive interpretation. Compare with the extracted source findings below.
Production areas and equipment were visibly dirty, contributing to insanitary conditions.
Supporting FDA text
Source excerpt · automated text-match checkProduction areas and equipment were visibly dirty.
Inadequate product evaluation and corrective action after microbial contamination in ISO 5 area.
Supporting FDA text
Source excerpt · automated text-match checkYou did not perform adequate product evaluation and take appropriate corrective action after microbial contamination was recovered within the ISO 5 aseptic processing area.
Quality control unit failed to ensure drug products meet CGMP and specifications.
Supporting FDA text
Source excerpt · automated text-match checkYour firm’s quality control unit failed to exercise its responsibility to ensure drug products manufactured are in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22).
Failed to thoroughly investigate batch discrepancies or specification failures.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed (21 CFR 211.192).
Failed to perform appropriate laboratory determination of conformance to final specifications before release.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to have, for each batch of drug product, appropriate laboratory determination of satisfactory conformance to final specifications for the drug product, including the identity and strength of each active ingredient, prior to release (21 CFR 211.165(a)).
Failed to establish adequate system for maintaining aseptic control equipment.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to establish an adequate system for maintaining equipment used to control the aseptic conditions (21 CFR 211.42(c)(10)(vi)).
Failed to establish adequate stability testing program to determine storage conditions and expiration dates.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to establish and follow an adequate written testing program designed to assess the stability characteristics of drug products and to use results of stability testing to determine appropriate storage conditions and expiration dates (21 CFR 211.166(a)).
Failed to establish and document accuracy, sensitivity, specificity, and reproducibility of test methods.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to establish and document the accuracy, sensitivity, specificity, and reproducibility of its test methods (21 CFR 211.165(e)).
Failed to exercise appropriate controls over computer systems to ensure only authorized personnel make changes.
Supporting FDA text
Source excerpt · automated text-match checkYour firm failed to exercise appropriate controls over computer or related systems to assure that only authorized personnel institute changes in master production and control records, or other records (21 CFR 211.68(b)).
Failed to address rounding and averaging of OOS results reported as passing.
Supporting FDA text
Source excerpt · automated text-match checkYou do not address the practice of rounding and averaging individual out of specification results and then ultimately reporting as a passing final result.
Failed to address significant figures for raw data before rounding and calculating final result.
Supporting FDA text
Source excerpt · automated text-match checkYou do not address the necessary significant figures needed for raw data before rounding and calculating the final reported result.
No completed validation report for rapid sterility test method demonstrating specificity and suitability.
Supporting FDA text
Source excerpt · automated text-match checkyou have not provided a completed validation report for your firm’s rapid sterility test method demonstrating the method is specific and suitable for its intended purpose.
Similar CGMP deficiencies at multiple sites demonstrate inadequate management oversight.
Supporting FDA text
Source excerpt · automated text-match checkThe FDA identified similar CGMP deficiencies at other facilities in your company’s network. CAPS Allentown and CAPS San Diego were also inspected and cited for CGMP deficiencies and insanitary conditions. These repeated failures at multiple sites demonstrate that management oversight and control over the manufacture of drugs is inadequate.
Findings extracted from the letter
Selected FDA passages, not the complete letter.
Source passage selected by the model
Source passage selected by the model
Source passage selected by the model
Source passage selected by the model
Source passage selected by the model
Source passage selected by the model
What FDA requested
Model-assisted summary. Consult the letter for complete requests and conditions.
- Provide copies of all completed and retroactive investigation reports for accuracy of data and records for production and analytical testing, invalid tests and out of specification results, and releasing drug products before all testing is completed
- Provide a cleaning validation report demonstrating adequacy of revised cleaning procedures for laboratory glassware
- Provide supporting documentation for remediation of floor stains in Rooms E and F (ISO 7)
- Provide supporting documentation regarding completion of refurbishing and passivating ISO 5 workstations
- Provide completed stability studies, including sterility, for products with previously established expiration dates using alternative studies
- Provide a completed investigation determining if any data or documents were modified or deleted due to unauthorized access
- Provide a completed validation report for the rapid sterility test method demonstrating specificity and suitability
- Address the practice of rounding and averaging individual out of specification results and reporting as passing final result, including significant figures for raw data before rounding and calculating final reported result
Sections and clauses cited
As cited in this historical letter, not a statement of current regulatory requirements.