Drugs

BRS Analytical Services, LLC

FDA issued a warning letter to BRS Analytical Services, LLC (St. Louis, MO, United States) on Sep 17, 2025, citing 21 CFR 211.42, 21 CFR 211.113 and 21 CFR 211.22. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “Your ISO 5 area used for aseptic compounding and filling sterile over-the-counter (OTC) (b)(4) drug products was fundamentally unsuitable for its intended use.”

St. Louis, MO, United StatesIssued Sep 17, 2025Posted Oct 21, 2025No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
5 findings · 3 issue types
Response due
Not stated in the letter
FDA asks for
3 actions
Named as possible actions
Seizure, injunction
Issued by
Center for Drug Evaluation and Research
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Facilities & equipment · 21 CFR 211.42(c)(10)The ISO 5 aseptic processing area had gaps in walls, dirty mesh screens, and inadequate differential pressure monitoring, posing a contamination risk.
Your ISO 5 area used for aseptic compounding and filling sterile over-the-counter (OTC) (b)(4) drug products was fundamentally unsuitable for its intended use. For example, your ISO 5 area had gaps in the wall intended to separate it from the immediately surrounding unclassified warehouse, including large gaps between most wall sections and the floor. Some of these gaps contained mesh screens that appeared to be dirty. Furthermore, you failed to maintain an adequate differential pressure between the ISO 5 area and the warehouse, and did not continuously monitor that pressure.
02Production & process controls · 21 CFR 211.113(b)The firm failed to establish and follow written procedures to prevent microbiological contamination of sterile drug products, including validation of aseptic and sterilization processes.
Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes (21 CFR 211.113(b)).
03Production & process controls · 21 CFR 211.113(b)Media fills did not accurately simulate commercial operations, with insufficient incubation units and duration.
Your media fills failed to accurately simulate commercial operations. You only incubated approximately (b)(4) of units for each media fill, rather than (b)(4) units. In contrast, your protocols required (b)(4) units that passed inspection to be incubated. In addition, each media fill lasted only approximately (b)(4) or less, although your commercial aseptic filling operations typically lasted (b)(4) days.
04Production & process controls · 21 CFR 211.113(b)The smoke study failed to demonstrate unidirectional airflow, as it was not conducted with actual equipment or under dynamic conditions.
Your smoke study did not adequately demonstrate unidirectional air flow in the ISO 5 area that was used for the aseptic filling of (b)(4) drug products. For example: • Your smoke study did not evaluate unidirectionality. Instead, you turned off the HEPA-(b)(4) fans, filled the ISO 5 area with smoke, then turned the fans on and verified that the room was cleared of smoke. • You failed to conduct a smoke study with your actual filling equipment present. • Your smoke study was not conducted under dynamic conditions.
05Quality unit & oversight · 21 CFR 211.22The quality unit failed to maintain adequate CGMP oversight, allowing distribution of sterile products manufactured under unacceptable conditions.
Your quality unit (QU) failed to maintain adequate CGMP oversight and allowed the distribution of sterile (b)(4) drug products manufactured under unacceptable conditions, which included poorly designed facilities, an unsuitable aseptic manufacturing process, and deficient environmental monitoring. You also failed to ensure implementation of an effective qualification and validation program, and perform adequate antimicrobial effectiveness studies for your multi-dose aqueous-based sterile (b)(4) drug products.

Additional FDA passages

1 extracted findings

Selected FDA passages, not the complete letter.

01

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

What FDA requested

  • Notify this office if you intend to resume your drug manufacturing operations at this site or in another location, and provide a summary of your remediations to demonstrate that you have appropriately completed all corrective actions and preventive actions (CAPA).
  • Engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. The qualified consultant should also perform a comprehensive audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your CAPA before you pursue resolution of your firm’s compliance status with FDA.
  • Respond to this office in writing within 15 working days, specifying what you have done to address any violations and to prevent their recurrence. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

FDA Warning Letter

54 paragraphs · 5 sections

Text as published on FDA.gov, retrieved Oct 18, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedSeptember 17, 2025
AddressedDear Ms. Bandrowsky

1Introduction

32 paragraphs

The United States Food and Drug Administration (FDA) inspected your drug manufacturing facility and contract testing laboratory, BRS Analytical Services, LLC, FEI 3023604380, at 11697 Lakeside Crossing Court, St. Louis, from March 10 to 26, 2025.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).

We reviewed your April 14, 2025 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.

During our inspection, our investigators observed specific violations including, but not limited to, the following.

1. Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups in aseptic processing areas. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.42(c)(10) and 211.63).

Cleanroom Design

Your ISO 5 area used for aseptic compounding and filling sterile over-the-counter (OTC) (b)(4) drug products was fundamentally unsuitable for its intended use. For example, your ISO 5 area had gaps in the wall intended to separate it from the immediately surrounding unclassified warehouse, including large gaps between most wall sections and the floor. Some of these gaps contained mesh screens that appeared to be dirty. Furthermore, you failed to maintain an adequate differential pressure between the ISO 5 area and the warehouse, and did not continuously monitor that pressure. The lack of both physical and aerodynamic segregation in your aseptic processing facility design posed an unacceptable risk to product sterility.

The ISO 5 area is critical because sterile drug products are exposed and are therefore vulnerable to contamination. Your aseptic manufacturing facility, equipment, and process must be designed, and operations must be executed, to minimize contamination hazards to your sterile drug product. The unacceptable design of your operation precluded the ability to maintain asepsis.

Environmental Monitoring

You failed to establish an adequate system for monitoring environmental conditions. For example, you did not routinely perform viable air monitoring during production, despite a procedural requirement to do so. In addition, your nonviable particle monitor was placed on top of the enclosed cabinet in which filling occurred instead of inside it, rendering the resulting data non-representative of the environmental conditions near the areas of critical exposure on the aseptic processing line. Finally, you failed to routinely review environmental monitoring data prior to batch release.

Vigilant and responsive environmental and personnel monitoring programs provide meaningful information on the state of control of the aseptic processing operation, and enable an early warning system that identifies emerging contamination hazards before sterility is compromised. Operations that include highly (b)(4) intensive aseptic activities warrant a more extensive environmental and personnel monitoring program, including but not limited to an emphasis on increased sampling that monitors ongoing batch production conditions more extensively.

Facility Maintenance Deficiencies

During the inspection, we observed your facility to be in a state of disrepair or unclean in several instances. This includes, but is not limited to, the following deficiencies within your aseptic processing room:

• Discoloration and apparent residue on light panels above the aseptic filling equipment during operations.• Chipped paint on a floor scale.• Discoloration on the (b)(4) sterilizer and a table.

2. Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes (21 CFR 211.113(b)).

Poor Aseptic Behavior

We observed poor practices in ISO 5 areas during your (b)(4) intensive aseptic processing of sterile (b)(4) drug products, including but not limited to:

• Operators blocked unidirectional airflow during routine production by placing their gloved hands and hooded, masked heads directly over open sterilized bottles.• The skin surrounding operators’ safety glasses was exposed in the ISO 5 area.• Use of nonsterile face masks.• Use of nonsterile paper towels in the ISO 5 area, including inside the filling cabinet.• Failure to seal a vessel containing sterile drug product. Instead of a securely fitted cap, you used an (b)(4) intended to cover an open port in the sterile (b)(4) holding tank in the ISO 5 area during the filling process, which was typically run for (b)(4) days and did not include additional sterilizing (b)(4). In addition, our investigators observed condensation inside the (b)(4), as well as air gaps that provided an avenue for ingress of (b)(4) air.

Inadequate Media Fill Program

Your media fills failed to accurately simulate commercial operations. You only incubated approximately (b)(4) of units for each media fill, rather than (b)(4) units. In contrast, your protocols required (b)(4) units that passed inspection to be incubated. In addition, each media fill lasted only approximately (b)(4) or less, although your commercial aseptic filling operations typically lasted (b)(4) days.

It is essential that (b)(4) media fill units be incubated and examined for evidence of microbial contamination. Also, to accurately simulate contamination risks, the duration of the process simulation for (b)(4) intensive lines normally should be no less than the length of the actual manufacturing process.

Inadequate Assurance of Sterilization

• The validation of the (b)(4) sterilization process used to sterilize direct product contact parts, including transfer hoses and sterilizing (b)(4), was inadequate. For example, the (b)(4) sterilization validation process did not include the use of biological indicators. Instead, (b)(4) water was placed in jars and tested for sterility. Notably, one of these jars of water tested positive for growth, but you did not conduct an investigation.• Sterilizing (b)(4) were not integrity tested for each batch of drug products manufactured.

It is essential that product contact equipment is sterile to be suitable for its intended use. Sterilization cycle validation is established through studies that incorporate rigorous physical and biological measurements. Between uses, sterile equipment must be held under ISO 5 conditions and continuously maintained in a manner that prevents contamination.

Inadequate Smoke Study

Your smoke study did not adequately demonstrate unidirectional air flow in the ISO 5 area that was used for the aseptic filling of (b)(4) drug products. For example:

• Your smoke study did not evaluate unidirectionality. Instead, you turned off the HEPA-(b)(4) fans, filled the ISO 5 area with smoke, then turned the fans on and verified that the room was cleared of smoke.• You failed to conduct a smoke study with your actual filling equipment present.• Your smoke study was not conducted under dynamic conditions.

3. Your firm’s quality control unit failed to exercise its responsibility to ensure drug products manufactured are in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22)

Your quality unit (QU) failed to maintain adequate CGMP oversight and allowed the distribution of sterile (b)(4) drug products manufactured under unacceptable conditions, which included poorly designed facilities, an unsuitable aseptic manufacturing process, and deficient environmental monitoring. You also failed to ensure implementation of an effective qualification and validation program, and perform adequate antimicrobial effectiveness studies for your multi-dose aqueous-based sterile (b)(4) drug products.

In addition, you failed to ensure that adequate procedures were followed describing the roles and responsibilities of the QU including, but not limited to, raw material supplier qualification.

Significant findings in this letter indicate that your QU was not fully exercising its authority or responsibility. Your firm must provide the QU with the appropriate authority and sufficient resources to carry out its responsibilities and consistently ensure drug quality.

2Drug Recall

1 paragraph

On April 17, 2025, FDA held a teleconference with you recommending that you remove from the U.S. market all batches of (b)(4) drug products currently in distribution. On April 21, 2025, you committed to ceasing the manufacture and distribution of all (b)(4) drug products and agreed to a voluntary recall of all (b)(4) drug products currently in distribution in the U.S. On April 23, 2025, you issued a voluntary recall of all (b)(4) drug products due to CGMP deviations and lack of assurance of sterility. The company announcement was posted to the FDA website: https://www.accessdata.fda.gov/scripts/ires/?Event=96741.

3Drug Production Ceased

2 paragraphs

We acknowledge your commitment dated June 24, 2025, to permanently cease production of all drugs at this facility.

Notify this office if you intend to resume your drug manufacturing operations at this site or in another location. You are responsible for resolving all deficiencies and systemic flaws to ensure that your firm is capable of ongoing CGMP compliance. In your notification to the Agency, provide a summary of your remediations to demonstrate that you have appropriately completed all corrective actions and preventive actions (CAPA).

4CGMP Consultant Recommended

2 paragraphs

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. The qualified consultant should also perform a comprehensive (b)(4)1 of your entire operation for CGMP compliance and evaluate the completion and efficacy of your CAPA before you pursue resolution of your firm’s compliance status with FDA.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

5Conclusion

5 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

Correct any violations promptly. Failure to promptly and adequately address this matter may result in regulatory or legal action without further notice including, without limitation, seizure and injunction. Unresolved violations may also prevent other Federal agencies from awarding contracts.

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3023604380 and ATTN: Russell Riley.

Sincerely,/S/

Francis GodwinDirectorOffice of Manufacturing QualityOffice of ComplianceCenter for Drug Evaluation and Research

Cc: (b)(4)(b)(6), (b)(7)(C)

_____________

1 i.e. Quality System, Facilities & Equipment System, Materials System, Production System, Packaging & Labeling System, and Laboratory Control System per FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Also cited: 21 CFR 210

Issue types

Record details

Issuing center
Center for Drug Evaluation and Research
Issuing office
Center for Drug Evaluation and Research
Location
St. Louis, MO, United States
Letter posted date
Oct 21, 2025
Letter issue date
Sep 17, 2025
Addressed to
Owner
Inspection dates
Mar 10, 2025
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,922 words · 35 recorded redactions
Published status
No published close-out
FDA reference
320-25-112
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.

Botable builds and runs a custom AI layer around the software you already use, so your team can do the job you hired them for.

Every letter by dateHow this database is built

FDA Warning Letter Alerts

Share this view

Send the same filters, search and view to a colleague.

You choose what to post or send. Sharing a link does not change access to this site.