Bioiberica, SAU
2 extracted findings · 2 model-assigned issue types
FDA source excerpt, selected passage
You failed to establish appropriate monitoring and controls for reworking batches of (b)(4) USP, API. In 2020 and 2021, approximately 23 batches of (b)(4) USP, API were reworked in your industrial (b)(4) because of microbiological out-of-specification or non-conforming high (b)(4), a class 3 residual solvent, content…
FDA published a close-out letter on Jan 29, 2025. The findings below are from the original warning letter.
Findings and supporting evidence
Model-assisted readings, not an exhaustive interpretation. Compare with the extracted source findings below.
Failed to establish monitoring and controls for reworking API batches due to microbiological and residual solvent issues.
Supporting FDA text
Source excerpt · automated text-match checkYou failed to establish appropriate monitoring and controls for reworking batches of (b)(4) USP, API. In 2020 and 2021, approximately 23 batches of (b)(4) USP, API were reworked in your industrial (b)(4) because of microbiological out-of-specification or non-conforming high (b)(4), a class 3 residual solvent, content results.
Used unvalidated equipment for rework, not part of the validated manufacturing process.
Supporting FDA text
Source excerpt · automated text-match checkThe use of the industrial (b)(4) was not part of the established process validation for (b)(4) USP, API.
No studies were performed to establish the effectiveness of the rework step.
Supporting FDA text
Source excerpt · automated text-match checkNo studies had been performed to establish the effectiveness of this rework step.
Industrial equipment lacked real-time monitoring to control rework performance.
Supporting FDA text
Source excerpt · automated text-match checkAdditionally, your industrial (b)(4) was not equipped with real time (b)(4) monitoring or a (b)(4) summary to monitor the performance of the (b)(4).
Reworked API batches were not placed on stability testing.
Supporting FDA text
Source excerpt · automated text-match checkReworked (b)(4) USP, API batches were not placed on stability.
No stability testing was done to confirm reworked batches matched validated process quality.
Supporting FDA text
Source excerpt · automated text-match checkNone of the reworked batches were placed on stability to ensure they were of quality equivalent to that produced by the validated process.
Findings extracted from the letter
Selected FDA passages, not the complete letter.
Source passage selected by the model
Source passage selected by the model
What FDA requested
Model-assisted summary. Consult the letter for complete requests and conditions.
- Assess manufacturing process including rework to control variability sources.
- Provide timelines for process performance qualification studies.
- Conduct independent assessment of manufacturing operations and microbiological hazards.
- Implement interim measures until corrective actions are completed.
- Conduct independent assessment and CAPA plan for stability program.
- Provide all procedures for remediated stability program.
- Provide rework procedure for evaluating equivalence to validated process.