Accupack Midwest, Inc.

FDA issued a warning letter to Accupack Midwest, Inc. (Cincinnati, OH, United States) on Aug 15, 2024, citing 21 CFR 211.160, 21 CFR 211.192 and 21 CFR 211.100. Subject: CGMP, Finished Pharmaceuticals, Adulterated.

From the letter: “Your firm has not established that your processes used to manufacture OTC drug products were validated.”

Cincinnati, OH, United StatesIssued Aug 15, 2024Posted Sep 24, 2024No close-out recorded

At a glance

What a reviewer notes before reading: findings, citations, the response deadline and what the letter warns of.

Violations
1 finding · 1 issue type
Response due
Not stated in the letter
FDA asks for
8 actions
Named as possible actions
Seizure, injunction
Issued by
Division of Pharmaceutical Quality Operations III · Office of Inspections and Investigations
Published status
No close-out recorded

AI assisted findings

Model-assisted reading of each issue. Open one to see the FDA text it comes from, and check it against the full letter.

01Production & process controls · 21 CFR 211.100(a)Manufacturing processes were not validated, equipment qualification was not performed, and water system lacked appropriate qualification.
Your firm has not established that your processes used to manufacture OTC drug products were validated. Equipment qualification had not been performed on drug product manufacturing equipment, and you lack appropriate qualification of your water system.

Additional FDA passages

3 extracted findings

Selected FDA passages, not the complete letter.

01

Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).

02

Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).

03

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

What FDA requested

  • A comprehensive remediation plan for the design, control, and maintenance of the water system.
  • A purified water system validation report. Also include the summary of any improvements made to system design and to the program for ongoing control and maintenance.
  • A procedure for your water system monitoring that specifies routine microbial testing of water to ensure its acceptability for use in each batch of drug products produced by your firm.
  • The current action/alert limits for total counts and objectionable organisms used for your Purified Water system. Ensure that the total count limits for your purified water are appropriately stringent in view of the intended use of each of the products produced by your firm.
  • A procedure governing your program for ongoing control, maintenance, and monitoring that ensures the remediated system consistently produce water that meets Purified Water, USP monograph specifications and appropriate microbial limits.
  • A detailed risk assessment addressing the potential effects of the observed water system failures on the quality of all drug product lots currently in U.S. distribution or within expiry. Specify actions that you will take in response to the risk assessment, such as customer notifications and product recalls.
  • A comprehensive, independent assessment of your overall system for investigating deviations, discrepancies, complaints, OOS results, and failures. Provide a detailed action plan to remediate this system. Your action plan should include, but not be limited to, significant improvements in investigation competencies, scope determination, root cause evaluation, corrective action and preventive action (CAPA) effectiveness, quality assurance oversight, and written procedures. Address how your firm will ensure all phases of investigations are appropriately conducted.
  • A detailed summary of your validation program for ensuring a state of control throughout the product lifecycle, along with associated procedures. Describe your program for process performance qualification (PPQ), and ongoing monitoring of both intra-batch and inter-batch variation to ensure a continuing state of control. A timeline for performing PPQ for each of your marketed drug products. Your process performance protocol(s), and written procedures for qualification of equipment and facilities. Provide a detailed program for designing, validating, maintaining, controlling and monitoring each of your manufacturing processes that includes vigilant monitoring of intra-batch and inter-batch variation to ensure an ongoing state of control. Also, include your program for qualification of your equipment and facility.

FDA Warning Letter

46 paragraphs · 3 sections

Text as published on FDA.gov, retrieved Oct 7, 2026. Layout added for reading; the wording is FDA’s. View on FDA.gov (opens in a new tab)

DatedAugust 15, 2024
Sent toCASE #680228
AddressedDear Mr. Proctor

1Introduction

26 paragraphs

The U.S. Food and Drug Administration (FDA) inspected your drug manufacturing facility, Accupack Midwest, Inc., FEI 1000122754, at 1060 Meta Drive, Cincinnati, Ohio 45237, from February 22 to 27, 2024.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations (CFR), parts 210 and 211 (21 CFR parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).

We reviewed your March 18, 2024, response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence. In addition, on June 17, 2024, FDA held a teleconference with you to discuss additional information concerning your CGMP operations, including test methods for your (b)(4) water system, process validation, and finished product testing.

During our inspection, our investigator observed specific violations including, but not limited to, the following.

1. Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).

Your firm contract manufactures over-the-counter (OTC) drug products, including sunscreens, anti-itch creams, and analgesics. Your firm uses water as a component in your drug products. However, you failed to establish adequate specifications for your component water. For example, you lacked adequate limits and testing for objectionable microorganisms. You also lacked total organic carbon or conductivity limits and testing to ensure that your water met Purified Water USP monograph specifications. You also failed to adequately monitor your water system to ensure that the system is operating properly and continuously producing water suitable for its intended use. Several failures were noted during your firm’s (b)(4) testing on your water samples where your firm resampled and retested the water without an appropriate investigation (see 21 CFR 211.192).

Without routine water monitoring of an appropriately designed system, you cannot ensure that your water meets minimum microbiological and chemical standards suitable for the manufacture of your drug products.

In response to this letter, provide:

A comprehensive remediation plan for the design, control, and maintenance of the water system.

A purified water system validation report. Also include the summary of any improvements made to system design and to the program for ongoing control and maintenance.

A procedure for your water system monitoring that specifies routine microbial testing of water to ensure its acceptability for use in each batch of drug products produced by your firm.

The current action/alert limits for total counts and objectionable organisms used for your Purified Water system. Ensure that the total count limits for your purified water are appropriately stringent in view of the intended use of each of the products produced by your firm.

A procedure governing your program for ongoing control, maintenance, and monitoring that ensures the remediated system consistently produce water that meets Purified Water, USP monograph specifications and appropriate microbial limits.

A detailed risk assessment addressing the potential effects of the observed water system failures on the quality of all drug product lots currently in U.S. distribution or within expiry. Specify actions that you will take in response to the risk assessment, such as customer notifications and product recalls.

A comprehensive, independent assessment of your overall system for investigating deviations, discrepancies, complaints, OOS results, and failures. Provide a detailed action plan to remediate this system. Your action plan should include, but not be limited to, significant improvements in investigation competencies, scope determination, root cause evaluation, corrective action and preventive action (CAPA) effectiveness, quality assurance oversight, and written procedures. Address how your firm will ensure all phases of investigations are appropriately conducted.

2. Your firm failed to establish written procedures for production and process control designed to assure that the drug products you manufacture have the identity, strength, quality, and purity they purport or are represented to possess (21 CFR 211.100(a)).

Your firm has not established that your processes used to manufacture OTC drug products were validated. Equipment qualification had not been performed on drug product manufacturing equipment, and you lack appropriate qualification of your water system.

Process validation evaluates the soundness of design and state of control of a process throughout its lifecycle. Each significant stage of a manufacturing process must be designed appropriately and assure the quality of raw material inputs, in-process materials, and finished drugs. Process qualification studies includes intensive monitoring and testing of throughout each significant process stage to characterize intra-batch variation and evaluates batches to determine whether an initial state of control has been established.

Successful process qualification studies are necessary before commercial distribution. Thereafter, ongoing vigilant oversight of process performance and product quality is necessary to ensure you maintain a stable manufacturing operation throughout the product lifecycle.

See FDA’s guidance document Process Validation: General Principles and Practices for general principles and approaches that FDA considers appropriate elements of process validation at https://www.fda.gov/media/71021/download.

In response to this letter, provide:

A detailed summary of your validation program for ensuring a state of control throughout the product lifecycle, along with associated procedures. Describe your program for process performance qualification (PPQ), and ongoing monitoring of both intra-batch and inter-batch variation to ensure a continuing state of control.

A timeline for performing PPQ for each of your marketed drug products.

Your process performance protocol(s), and written procedures for qualification of equipment and facilities.

Provide a detailed program for designing, validating, maintaining, controlling and monitoring each of your manufacturing processes that includes vigilant monitoring of intra-batch and inter-batch variation to ensure an ongoing state of control. Also, include your program for qualification of your equipment and facility.

2CGMP Consultant Recommended

3 paragraphs

We acknowledge your commitment to temporarily cease the production of drugs at this facility while you implement corrective actions.

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit1 of your entire operation for CGMP compliance and evaluate the completion and efficacy of your CAPAs before you pursue resolution of your firm’s compliance status with the FDA.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

3Conclusion

7 paragraphs

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

Correct any violations promptly. Failure to promptly and adequately address this matter may result in regulatory or legal action without further notice including, without limitation, seizure and injunction. Unresolved violations may also prevent other Federal agencies from awarding contracts.

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to address any violations.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Your response should refer to Case # 680228. Please address your reply via email to: ORAPHARM3_RESPONSES@fda.hhs.gov

Attention: Sneha Patel, Compliance Officer U.S. Food and Drug Administration Division of Pharmaceutical Quality Operations III

If you have questions regarding the contents of this letter, please contact Compliance Officer, Sneha Patel at (313) 393-8254.

Sincerely, /S/

Rebecca E. Dowd Program Division Director Division of Pharmaceutical Quality Operation III Office of Regulatory Affairs

______________________

1 i.e. Quality System, Facilities & Equipment System, Materials System, Production System, Packaging & Labeling System, and Laboratory Control System per FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations at https://www.fda.gov/media/71023/download.

Citations and trends

Each 21 CFR section, ISO 13485 clause and issue type in this letter, how often it appears across all letters, and its trend by the year FDA issued the letters. 2026 runs to Nov 3, 2026, compared with the same dates last year. Select a row or a bar to see those letters in Letters. As cited in this historical letter, not a statement of current requirements.

Regulations

Also cited: 21 CFR 210

Issue types

Record details

Issuing center
Office of Inspections and Investigations
Issuing office
Division of Pharmaceutical Quality Operations III
Location
Cincinnati, OH, United States
Letter posted date
Sep 24, 2024
Letter issue date
Aug 15, 2024
Addressed to
President
Inspection dates
Feb 22, 2024
Response window
Not verified in this snapshot. Consult the original letter.
Record length
1,446 words · 2 recorded redactions
Published status
No published close-out
Original letter
View on FDA.gov (opens in a new tab)
Dataset last checked
Nov 11, 2026 · How this is built

A response window is not a calculated due date. Source excerpts are selected passages. Finding interpretations and categories are model-assisted. Verify the original letter before relying on a finding.

See the pattern across 1,707 lettersFind letters like this →
Keep exploring

More drug letters

Recent records for the same product type. Your previous filters remain available when you return.

Keep exploring

Find letters like this →
For regulated teams

Put this kind of reading to
work on your own records.